• Title/Summary/Keyword: Shielding performance

Search Result 261, Processing Time 0.034 seconds

Preparation and Properties of the Fast-Curing γ-Ray-Shielding Materials Based on Polyurethane

  • Ni, Minxuan;Tang, Xiaobin;Chai, Hao;Zhang, Yun;Chen, Tuo;Chen, Da
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1396-1403
    • /
    • 2016
  • In this study, fast-curing shielding materials were prepared with a two-component polyurethane matrix and a filler material of PbO through a one-step, laboratory-scale method. With an increase in the filler content, viscosity increased. However, the two components showed a small difference. Curing time decreased as the filler content increased. The minimum tack-free time of 27 s was obtained at a filler content of 70 wt%. Tensile strength and compressive strength initially increased and then decreased as the filler content increased. Even when the filler content reached 60 wt%, mechanical properties were still greater than those of the matrix. Cohesional strength decreased as the filler content increased. However, cohesional strength was still greater than 100 kPa at a filler content of 60 wt%. The ${\gamma}$-ray-shielding properties increased with the increase in the filler content, and composite thickness could be increased to improve the shielding performance when the energy of ${\gamma}$-rays was high. When the filler content was 60 wt%, the composite showed excellent comprehensive properties.

Electromagnetic Interference Shielding Characteristics of Electroless Nickel Plated Carbon Nanotubes (무전해 니켈 도금된 탄소나노튜브의 전자파 차폐 특성)

  • Kim, Do Young;Yun, Kug Jin;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.268-273
    • /
    • 2014
  • In this study, multi-walled carbon nanotubes (MWCNT) were treated with nickel by electroless plating method for improving electromagnetic interference (EMI) shielding performance of MWCNT. The physical properties of electroless plated MWCNT were analyzed by using ultra-high resolution scanning electron microscope (UHR-SEM), thermogravimetry (TGA), sheet resistance analyzer and EMI shielding analyzer. EMI shielding efficiencies of nickel electroless plated MWCNT were measured to be 16 dB from 800 MHz band, which was 1.6 times increased compared to that of the activated MWCNT. Also, the average sheet resistance of nickel electroless plated MWCNT was measured to be $70{\Omega}/sq$, which was 56% decreased compared to that of the activated MWCNT. This result could be attributed to the plating morphology on the surface of MWCNT. This result could be attributed to uniformity of plating morphology on the surface, which has more effect on EMI shielding efficiency than the amount of nickel plating.

A Study on Searching Stabled EMI Shielding Effectiveness Measurement Point for Military Communication Shelter Using Support Vector Machine and Process Capability Analysis (서포트 벡터 머신과 공정능력분석을 이용한 군 통신 쉘터의 EMI 차폐효과 안정 포인트 탐색 연구)

  • Ku, Ki-Beom;Kwon, Jae-Wook;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.321-328
    • /
    • 2019
  • A military shelter for communication and information is necessary to optimize the integrated combat ability of weapon systems in the network centric warfare. Therefore, the military shelter is required for EMI shielding performance. This study examines the stable measurement points for EMI shielding effectiveness of a military shelter for communication and information. The measurement points were found by analyzing the EMI shielding effectiveness measurement data with data mining technique and process capability analysis. First, a support vector machine was used to separate the measurement point that has stable EMI shielding effectiveness according to set condition. Second, this process was conducted with process capability analysis. Finally, the results of data mining technique were compared with those of process capability analysis. As a result, 24 measurement points with stable EMI shielding effectiveness were found.

An Experimental Study on Development of EMP Shielding Concrete Using Carbon-Based Materials and Industrial By-Products (카본계 재료 및 산업부산물을 활용한 EMP 차폐 콘크리트 개발에 관한 실험적 연구)

  • Min-Sung Kim;Cheol-Hyun Yoon;Seung-Ho Byun;Tae-Beom Min
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.48-54
    • /
    • 2023
  • In this research, The basic physical properties and EMP shielding performance by thickness were evaluated for optimum composition of EMP shield concrete that can be applied on-site by mixing carbon-based materials with high conductivity into concrete that uses electric furnace oxidized slag (EOS). As a result of the evaluation, it was confirmed that the slump decreased as the amount of mixed carbon fib er (CF) increased, and increased when milled carb on (MCF) was mixed. As for the compressive strength, it was confirmed that EOS enhanced the strength compared to NA, and it was confirmed that the strength decreased when CF and MCF were mixed. As the thickness of the EMP shielding measurement increases, the shielding rate increases, and it was confirmed that the type of conductive material and the thickness of the test specimen have a greater influence on the shielding rate than the Amount of conductive material added. As a result of a comparative evaluation, EOS CF 0.2 is considered suitable for EMP shield concrete formulation.

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Study on Rod Position Indication System using Permanent Magnets with Shielding Plates for a Control Rod Drive Mechanism

  • Lee, Jae Seon;Cho, Sang Soon;Kim, Jong Wook
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.439-443
    • /
    • 2015
  • A control rod drive mechanism (CRDM) is an electromechanical equipment that provides linear movement for the control rods to control the nuclear reactivity in a nuclear reactor. A rod position indication system (RPIS) detects the control rod's position. To enhance the measurement accuracy of the system, a magnetostrictive type sensor with capability of generating operation limiting signals would be adapted instead of a conventional RPIS for a CRDM. An RPIS was modelled for a numerical analysis with the permanent magnets at the stationary limit positions and magnetic shielding plates with a moving permanent magnet. The performance analysis of the RPIS were conducted, and the results were discussed here.

An Experimental Study on Pozzolanic Reactivity of the Neutron Shielding Mortar Containing Borosilicate Glass Powder (붕규산 유리 분말을 혼입한 차폐용 모르타르의 포졸란 반응성에 관한 실험)

  • Jang, Bo-Kil;Kim, Ji-Hyun;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.162-163
    • /
    • 2015
  • A borosilicate glass was powdered to incorporation into the cement for the purpose of improving the neutron shielding performance of concrete. The particle size of the borosilicate glass powder was prepared by a similar to that of cement. 50×50×50mm size of cube specimens were measured a compressive strength. As a result, compressive strength of 10% borosilicate glass powder replaced specimens were improved than that of plain specimens.

  • PDF

Nordic research and development cooperation to strengthen nuclear reactor safety after the Fukushima accident

  • Linde, Christian;Andersson, Kasper G.;Magnusson, Sigurdur M.;Physant, Finn
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.647-653
    • /
    • 2019
  • A comprehensive study of photon interaction features has been made for some alloys containing Pd and Ag content to evaluate its possible use as alternative gamma radiations shielding material. The mass attenuation coefficient (${\mu}/{\rho}$) of the present alloys was measured at various photon energies between 81 keV - 1333 keV utilizing HPGe detector. The measured ${\mu}/{\rho}$ values were compared to those of theoretical and computational (MCNPX code) results. The results exhibited that the ${\mu}/{\rho}$ values of the studied alloys are in same line with results of WinXCOM software and MCNPX code results at all energies. Moreover, Pd75/Ag25 alloy sample has the maximum radiation protection efficiency (about 53% at 81 keV) and lowest half value layer, which shows that Pd75/Ag25 has superior gamma radiation shielding performance among the compared other alloys.

Characteristics of Superconductive Pb shield for a Whole Head MEG System (헬멧형 뇌자도 장치로의 활용을 위한 Pb 초전도 차폐의 특성)

  • Yu, K.K.;Kim, K.;Lee, Y.H.;Kwon, H.
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.30-35
    • /
    • 2009
  • We have investigated the characteristics of a superconductive Pb shield for hemispherical shape and plate to improving signal-to-noise ratio(SNR) of biomagnetism. We measured the shielding factor for the position of helmet shape Pb and for changing the distance from Pb surface. To make a uniform magnetic field, a $1.5m{\times}1.5m$ set of the helmholtz coils activated at several frequencies. The shielding factor of hemispherical shape Pb was from 20 to 57 dB and of Pb plate was about $6{\sim}26dB$ as a function of distance from the lead surface. The shielding factor was rapidly reduced as increasing the distance from Pb surface. The white noise of superconductive quantum interference device(SQUID) with a superconductive shield was about $12fT/Hz^{1/2}$ at 1 Hz, $7fT/Hz^{1/2}$ at 100 Hz. The white noise was more increased about two times than conventional SQUID system without Pb shielding. An auditory signal was measured by first order gradiometer and magnetometer with Pb superconductive shield and compared the SNR. The SQUID system with Pb shield had better performance at low frequency noise level.

  • PDF

Evaluation for Mechanical Properties of Compress Strength and Dry Density of Concrete at NPP (원전 시설용 콘크리트의 압축강도 및 건조밀도 특성 평가)

  • Lee, Young-Dae;Kim, Gyu-Yong;Shin, Kyoung-Su;Nam, Jeong-Soo;Lee, Tae-Gyu;Choe, Gyeong-Choel
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.53-54
    • /
    • 2011
  • The facilities producing the nuclear energy chosen for resolving the recent global energy problem have been increasingly constructed, and hence more frequent durability tests on radiation shielding concrete are required due to NPP(Nuclear Power Plant) life extension and increase of radioactive waste repositories. Bulk dry density is one of the critical factors ensuring the durability and performance of the radiation shielding concrete because the design of the radiation shielding reinforced concrete structures for NPPs is based on the bulk dry density of the concrete. Bulk density of unconsolidated shielding concrete can be calculated utilizing a test assuring to satisfy the bulk dry density, or existing credible data set. This study evaluated correlation between bulk density and bulk dry density of the concrete used for Korean NPPs (y=1.0913X-0.2458) and developed a correlation expression considering standard deviation of bulk dry density (y=1.0913X-0.3358).

  • PDF