• Title/Summary/Keyword: Shielding Rates

Search Result 75, Processing Time 0.031 seconds

Radiation Shielding Analysis for the X-ray Facility (X-선 발생장치 시설의 방사선 차폐 해석)

  • Kwon, Seog-Guen;Choi, Ho-Sin;Moon, Philip-S.;Yook, Jong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.34-39
    • /
    • 1987
  • Radiation shielding analysis for a 6MeV X-ray facility was carried out. The primary and leakage radiation for the facility can be evaluated based on the methodology in NCRP No. 49 and 51. The present study deals with radiation scattering analysis for the outside and inside door of the facility based on the albedo concept. The calculated dose rates were compared with the results of MORSE-CG code calculation and the measured data, resulting in a good agreement, even though there existed some deviation for the inside door. These results can be utilized to the radiation shielding design of the medical and industrial X and gamma ray facilities, and to the safety evaluation of these facilities.

  • PDF

Evaluation of Radiation Shielding Rate of Lead Aprons in Nuclear Medicine (핵의학과에서 사용하는 납 앞치마의 방사선 차폐율 평가)

  • Han, Sang-Hyun;Han, Beom-Heui;Lee, Sang-Ho;Hong, Dong-Heui;Kim, Gi-Jin
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • Considering that the X-ray apron used in the department of radiology is also used in the department of nuclear medicine, the study aimed to analyze the shielding rate of the apron according to types of radioisotopes, thus ${\gamma}$ ray energy, to investigate the protective effects. The radioisotopes used in the experiment were the top 5 nuclides in usage statistics $^{99m}Tc$, $^{18}F$, $^{131}I$, $^{123}I$, and $^{201}Tl$, and the aprons were lead equivalent 0.35 mmPb aprons currently under use in the department of nuclear medicine. As a result of experiments, average shielding rates of aprons were $^{99m}Tc$ 31.59%, $^{201}Tl$ 68.42%, and $^{123}I$ 76.63%. When using an apron, the shielding rate of $^{131}I$ actually resulted in average dose rate increase of 33.72%, and $^{18}F$ showed an average shielding rate of -0.315%, showing there was almost no shielding effect. As a result, the radioisotopes with higher shielding rate of apron was in the descending order of $^{123}I$, $^{201}Tl$, $^{99m}Tc$, $^{18}F$, $^{131}I$. Currently, aprons used in the nuclear medicine laboratory are general X-ray aprons, and it is thought that it is not appropriate for nuclear medicine environment that utilizes ${\gamma}$ rays. Therefore, development of nuclear medicine exclusive aprons suitable for the characteristics of radioisotopes is required in consideration of effective radiation protection and work efficiency of radiation workers.

Development of an Infiltration and Ventilation Model for Predicting Airflow Rates within Buildings (빌딩 내의 공기유동량 예측을 위한 누입 및 환기모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.23 no.2
    • /
    • pp.207-218
    • /
    • 2014
  • A ventilation model was developed for predicting the air change per hour(ACH) in buildings and the airflow rates between zones of a multi-room building. In this model, the important parameters used in the calculation of airflow are wind velocity, wind direction, terrain effect, shielding effect by surrounding buildings, the effect of the window type and insect screening, etc. Also, the resulting set of mass balance equations required for the process of calculation of airflow rates are solved using a Conte-De Boor method. When this model was applied to the building which had been tested by Chandra et al.(1983), the comparison of predicted results by this study with measured results by Chandra et al. indicated that their variations were within -10%~+12%. Also, this model was applied to a building with five zones. As a result, when the wind velocity and direction did not change, terrain characteristics influenced the largest and window types influenced the least on building ventilation among terrain characteristics, local shieldings, and window types. Except for easterly and westerly winds, the ACH increased depending on wind velocity. The wind direction had influence on the airflow rates and directions through openings in building. Thus, this model can be available for predicting the airflow rates within buildings, and the results of this study can be useful for the quantification of airflow that is essential to the research of indoor air quality(temperature, humidity, or contaminant concentration) as well as to the design of building with high energy efficiency.

Quantitative Evaluation of Radiation Dose Rates for Depleted Uranium in PRIDE Facility

  • Cho, Il Je;Sim, Jee Hyung;Kim, Yong Soo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.378-383
    • /
    • 2016
  • Background: Radiation dose rates in PRIDE facility is evaluated quantitatively for assessing radiation safety of workers because of large amounts of depleted uranium being handled in PRIDE facility. Even if direct radiation from depleted uranium is very low and will not expose a worker to significant amounts of external radiation. Materials and Methods: ORIGEN-ARP code was used for calculating the neutron and gamma source term being generated from depleted uranium (DU), and the MCNP5 code was used for calculating the neutron and gamma fluxes and dose rates. Results and Discussion: The neutron and gamma fluxes and dose rates due to DU on spherical surface of 30 cm radius were calculated with the variation of DU mass and density. In this calculation, an imaginary case in which DU density is zero was added to check the self-shielding effect of DU. In this case, the DU sphere was modeled as a point. In case of DU mixed with molten salt of 50-250 g, the neutron and gamma fluxes were calculated respectively. It was found that the molten salt contents in DU had little effect on the neutron and the gamma fluxes. The neutron and the gamma fluxes, under the respective conditions of 1 and 5 kg mass of DU, and 5 and $19.1g{\cdot}cm^{-3}$ density of DU, were calculated with the molten salt (LiCl+KCl) of 50 g fixed, and compared with the source term. As the results, similar tendency was found in neutron and gamma fluxes with the variation of DU mass and density when compared with source spectra, except their magnitudes. Conclusion: In the case of the DU mass over 5 kg, the dose rate was shown to be higher than the environmental dose rate. From these results, it is concluded that if a worker would do an experiment with DU having over 5 kg of mass, the worker should be careful in order not to be exposed to the radiation.

Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.

Evaluationof Exposure Levels and Detection Rate of Hazardous Factors in the Working Environment, Focused on the Aluminum Die Casting Process in the Automobile Manufacturing Industry (자동차 부품제조 사업장의 유해인자 노출 농도수준 및 검출율 - 알루미늄 다이캐스팅 공정을 중심으로 -)

  • Lee, Duk-Hee;Moon, Chan-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.100-107
    • /
    • 2018
  • Objectives: This study examines exposure to hazardous substances in the working environment caused by exposure to toxic substances produced in the aluminum die casting process in the automobile manufacturing industry. Materials and Methods: The exposure concentration levels, detection rates and time-trend of 15 hazardous factors in the aluminum die casting process over 10 years(from 2006 to 2016) were used as a database. Results: The study found that hazardous factors in the aluminum die casting process were mostly metals. The rate for detected samples was 70.6%(405 samples), and that for not detected samples was 29.4%. The noise for an eight-hour work shift showed a 49.7% exceedance rate for TLV-TWA. Average noise exposure was 89.0 dB. The maximum exposure level was 105.1 dB. Conclusion: The high numbers of no-detection rates for hazardous substance exposure shows that there is no need to do a work environment measurement. Therefore, alternatives are necessary for improving the efficiency and reliability of the work environment measurement. Moreover, to prevent noise damage, reducing noise sources from automation, shielding, or sound absorbents are necessary.

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

Synthesis of nanometric tungsten powders by solid state combustion method (고상연소반응법에 의한 나노텅스텐분말의 합성)

  • H.H. Nersisyan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.93-93
    • /
    • 2003
  • Tungsten and tungsten heavy alloys have widespread application as radiation shielding devices and heavy duty electrical contacts. High density and good room temperature mechanical properties have generated interest in evaluating tungsten and tungsten alloys as kinetic energy penetrators against armor. Nowdays ultra fine-grained tungsten powders are in great interest because higly dense structures can be obtained at low temperature, pressure and lower sintering time. Several physical md chemical methods are available for the synthesis of nanometric metal Powders: ball milling, laser abalation, vapor condensation, chemical precipitation, metallic wire explosion i.e. However production rates of the above mentioned methods are low and further efforts are needed to find out large-scale synthesis methods. From this point of view solid state combustion method ( known as SHS) represents undoubted interest.

  • PDF

Calculations of Shielding Failure Rates According To The Hillside Angles (대지경사각을 고려한 차례실패 사고율 검토)

  • Kang, Y.W.;Kwak, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.615-617
    • /
    • 2005
  • 대기중에 위치한 뇌운안에 전하가 떠다니는 상태에서는 구름안과 주변에 높은 전계의 전위가 발생한다. 이 전하가 축적되면 대지 방전이 발생하고 송전선로 등에 뇌격이 침입하게 된다. 뇌 방전은 수 km에 달하는 대기중에 발생하는 거대한 전기현상이지만 이 낙뢰가 전기의 흐름이라는 것은 벤자민 프랭클린의 현장 시험에 대해 최초로 증명되었다. 이러한 대기중에 발생하는 거대한 전기현상인 낙뢰가 송전선로에 침입하여 송선선로 애자련을 섬락시키는 과정은 대단히 복잡한 전자기적인 현상이다. 그것은 가스 방전 현상, 감속에 중요한 역할을 하는 전자계의 빠른 변화, 도체와 철탑에 나타나는 코로 나와 관련된 비선형 효과 및 주파수 및 전류와 관련된 대지의 임피던스 통 다양한 현상이 종합적으로 관련된다. 따라서 가공 송전선로의 낙뢰에 대한 동작특성의 평가시 낙뢰 현상의 불규칙한 특성 및 신뢰할만한 데이터의 부족에 따른 많은 불확실성이 존재한다. 이 때문에 가공 송전선로에서 낙뢰에 의한 트립(Trip) 사고수의 계산을 위해 단순화된 방법이 아주 유용하며 효과적일 수 있다. 본 논문에서는 EGM (Electrogeometric Model) 모델을 사용하여 대지경사자의 크기에 따른 차폐실패 트립 사고율의 영향을 검토하였다.

  • PDF

The Study on the Calculation Algorism of Lightning Shielding Failure Outage Rates (낙뢰에 의한 송전선로의 차폐실패 사고율 계산 알고리즘 검토)

  • Kang, Y.W.;Kwak, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.621-623
    • /
    • 2005
  • 산업이 고도화되고 전력수요가 증가함에 따라 전력의 안정적인 공급에 대한 국민들의 요구가 점점 증가하고 있다. 그러나 전력을 수송하는 대부분의 송전선로는 가공 송선선로로서 낙뢰에 의한 고장에 노출되어 있어 한전에서는 이를 최소화하려는 노력을 하고 있다. 현재 한전에서는 년간 100km당 1건 이내로 낙뢰에 의한 고장을 제한하는 것을 목표치로 설계하여 운영하고 있으나 낙뢰에 의한 고장을 더욱 감소시키기 위하여 각종 내뢰 시책을 시행하고 있다. 이를 위해서는 근본적으로 낙뢰에 의한 송전선로의 고장을 가능한한 정확하게 예측하는 것이 중요하며, 본 논문에서는 낙뢰 고장 예측 계산을 위해 중요한 요소인 차폐실패 고장률 계산 알고리즘을 검토하고자 한다.

  • PDF