• Title/Summary/Keyword: Shield Cable

Search Result 107, Processing Time 0.021 seconds

Analysis on Current Distribution in Multi-layer HTSC Power Cable with Shield Layer (차폐층을 갖는 다층고온초전도 전력케이블의 전류분류 분석)

  • Lee Jong-Hwa;Lim Sung-Hun;Yim Seong-Woo;Du Ho-Ik;Han Byoung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.3
    • /
    • pp.273-279
    • /
    • 2006
  • High-$T_c$ superconducting (HTSC) power cable is one of the interesting parts in power application using HTSC wire. However, its stacked structure makes the current distribution between conducting layers non-uniform due to difference between self inductances of conducting layers and mutual inductances between two conducting layers, which results in lower current transmission capacity of HTSC power cable. In this paper, the transport current distribution between conducting layers was investigated through the numerical analysis for the equivalent circuit of HTSC power cable with a shield layer, and compared with the case of without a shield layer. The transport current distribution due to the increase of the contact resistance in each layer was improved. However, its magnetization loss increased as the contact resistance increased. It was confirmed from the analysis that the shield layer was contributed to the improvement of the current distribution between conducting layers if the winding direction and the pitch length were properly chosen.

Thermal and Mechanical Properties of Insulation Materials for Underground Power Cable (지중 전력케이블용 절연재료의 열적 특성 및 기계적 특성)

  • Lee, Kyoung-Yong;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.138-141
    • /
    • 2004
  • In this paper, we Investigated effects on impurities and water of semiconductive shield through a thermal, mechanical, and absorption experiment to estimate performance of insulating materials in power cable. Specimens had been prepared 22[kV], 154[kV] XLPE power cables and then were made of sheet form with XLPE and semiconductive shield with dimension of 0.4[mm] ~1.2[mm] of thickness from power cable. Heat capacity $({\Delta}H)$ and glass trasition temperature (Tg) of XLPE sheet were measured by DSC (Differential Scanning Calorimetry). We could know that thermal stabilities of 154[kV] are more excellent than 22[kV] from this experimental result. The strain of mechanical properties in 22[kV] and 154[kV] XLPE was 486[%], 507[%] and stress was 1.74$[kgf/mm^2]$, 1.80$[kgf/mm^2]$. The absorption contents of existing semiconductive shield were measured 710[ppm] to 1,090[ppm], and semiconductive shield of 22[kV] cable was measured 14,750[ppm] to 24,780[ppm]. We thermal and mechanical properties of 154[kV] could know more excellent than 22[kV] from this experimental result.

  • PDF

Analysis on the behavior of shield TBM cable tunnel: The effect of the distance of backfill grout injection from the end of skin plate (뒷채움 주입 거리에 따른 전력구 쉴드 TBM 터널의 거동 특성 분석)

  • Cho, Won-Sub;Song, Ki-Il;Ryu, Hee-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.213-224
    • /
    • 2014
  • Recently, tunnelling with TBM is getting popular for the construction of cable tunnel in urban area. Mechanized tunnelling method using shield TBM has various advantages such as minimization of ground settlement and prevention of vibration induced by blasting that should be accompanied by conventional tunnelling. In Korea, earth pressure balance (EPB) type shield TBM has been mainly used. Despite the popularity of EPB shield TBM for cable tunnel construction, study on the mechanical behavior of cable tunnel driven by shield TBM is insufficient. Especially, the effect of backfill grout injection on the behavior of cable tunnel driven by shield TBM is investigated in this study. Tunnelling with shield TBM is simulated using 3D FEM. The distance of backfill grout injection from the end of shield skin varies. Sectional forces such as axial force, shear force and bending moment are monitored. Vertical displacement at the ground surface is measured. Futhermore, the relation between volume loss and the distance of backfill grout injection from the end of skin plate is derived. Based on the stability analysis with the results obtained from the numerical analysis, the most appropriate injection distance can be obtained.

Steady and Transient State Analysis on Three Phase-in One Enclosure Type HTS Cable (3상 일괄형 Pipe Type HTS 케이블의 정상 및 과도상태 해석)

  • Jang, Ju-Yeong;Lee, Jong-Beom;Kim, Yong-Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1748-1753
    • /
    • 2010
  • This paper suggests an improved technique to establish the modeling regarding steady and transient state on three phase-in one cryostat type HTS(High Temperature Superconducting) cable. The proposed modeling is established using EMTP/ATPDraw and TACS and MODELS provided by that. It has higher accuracy than the conventional method, as the actual HTS cable is modelled. Steady and transient state analysis performed by EMTP/ATPDraw calculate the current of conductor, shield and former, respectively. In case of the transient state modeled quench state occurred by a single line-to-ground fault, current of conductor shield and former are also calculated, respectively. Especially, various fault resistances and angles are considered to improve the reliability during transient state analysis. Analysis results reveal that the proposed technique improves the accuracy of modeling.

A Study on Shield Wire Stripping of Micro Coaxial Cable for Medical Device Using Nd:YAG Laser (Nd:YAG 레이저를 이용한 의료기기용 마이크로 동축케이블의 실드선 탈피에 관한 연구)

  • Lee, Jeong-Wan;Kim, Jung-Hoon
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.35-41
    • /
    • 2006
  • Recently, as ultrasonic medical devices are gradually developed, many of those requires smaller and more precision coaxial cables in probe. So, the use of micro coaxial cable becomes an efficient solution for ultrasonic machine. However, there are many difficulties in stripping micro coaxial cable by traditional mechanical process. In this paper, we use the Nd-YAG laser for the efficient stripping of conduct wire of cable. We propose a new method to strip the shield wire of micro coaxial cable. Through some experiments, we found that there is a new possibility in the proposed method. Also, in order to enhance the performance, we propose a preprocess of the cable before stripping.

  • PDF

Analysis of HEMP Coupling Signal for a Coaxial Cable with Braided Shields (Braided Shield를 가진 동축 케이블의 HEMP 결합 신호 해석)

  • Lee, Jin-Ho;Cho, Jea-Hoon;Kim, Eung-Jo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.790-796
    • /
    • 2011
  • The system which is exposed in the impact range of High-altitude Electromagnetic Pulse(HEMP) may get serious damage because HEMP has a very large electric field value, a very fast rise-time, and so on. Electromagnetic analysis should be performed for signals coupled to the opening or cables of the system prior to derive the system design specifications in order to protect the system against HEMP adequately. In this paper, we analyzed the HEMP coupled signals for the coaxial cable which is generally used to transmit and receive video or RF signals and compared the coupled signal of the one wire with that of the inner conductor of a coaxial cable to confirm the decreased effect of HEMP by the shield. The coaxial cable is analyzed by the external and internal region of the shield separately. For the external region of the coaxial cable, general scattered equation was applied to calculate currents on the surface of the shield and for internal region of the coaxial cable, chain matrix algorithm is used. To verify this paper the analyzed results were compared the results of the existing paper and the two results have good agreements.

Applicability estimation for cable assembling method of shield tunnel using field test construction (현장 조립 시험시공을 통한 쉴드터널 강연선 체결 기술의 적용성 평가)

  • Kim, Dong-Min;Ma, Sang-Joon;Lee, Young-Sub
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.1
    • /
    • pp.11-23
    • /
    • 2015
  • In this study, the new segment assembling method using cable tensible force was developed to improve the problem of bolt assembling method of shield tunnel. In the field test construction, cable assembling method reduced the assembling time of segment in comparison with bolt assembling method because of guide role of segment shear-key. In the result of measuring the necessary time for segment assembling process, it took 420sec to assemble one segment in bolt method and 400sec to assemble one segment in cable method, but in case of using the cable automatic feeder, it could reduce the necessary time as 60sec in comparison with bolt assembling method. The cable automatic system modeling using BIM, that connected shield TBM also will be utilized in the area of design TBM, excavation plan, method process understanding, construction management and so on.

The Research into Connecting System for Aerial Bundled Cable in Distribution Line (ABC 배전 접속 시스템에 대한 연구)

  • 이용순;최경선;주종민;이철호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.495-498
    • /
    • 2001
  • The distribution line through which electricity is supplied from substation to customer generally varies by underground line and overhead line. In contrast that the underground line is shielded, the overhead lines do not have the shield layer. To overcome this weak point of the overhead lines, the aerial bundled cable(ABC) connection systems have been developed. The basic concept of the ABC connection system is the application of the underground cable system containing complete shield layer to the overhead cable system. The ABC system is the innovative technologies which enable the prevention of electric shocks, reduction of the maintenance charge and damage of the cable. This paper give a full detail of vertical connection system applied within a country.

  • PDF

A Study on the Composition of Superconducting Power Cable Using the Multi-cable (멀티케이블을 이용한 초전도 전력케이블의 구성에 관한 연구)

  • Choi, S.J.;Lee, S.J.;Sim, K.D.;Cho, J.W.;Lee, S.K.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.42-46
    • /
    • 2010
  • The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. The superconducting tapes of transmission layers and shield layer are wound in a cylindrical shape with a winding pitch. The radius of cylinder and the number of superconducting tapes are decided considering to the transmission current capacity and the critical current of superconducting tapes. The increasement of transmission current capacity will increase in volume of HTS cable system. In this paper, the composition method of supercondcuting power cable using the multi-cable is presented. The coated conductor tape can be wound on the smaller cylinder because it has the smaller critical bending diameter than the BSCCO tape. A small-scale cable was composed using the coated conductor tapes and a multi-cable is composed using a small-scale cable considering to transmission current capacity. Even increase of transmission current capacity, this method has advantage that the HTS superconducting power cable can be composed easily. The 22.9 kV and 154 kV superconducting power cable was composed using the presented method.