• 제목/요약/키워드: Shell-and-tube

검색결과 226건 처리시간 0.022초

CFC11, CFC12, HCFC22 대체냉매의 응축 열전달계수 (Condensation heat transfer coefficients of alternative refrigerants for CFC11, CFC12 and HCFC22)

  • 정동수
    • 대한설비공학회지:설비저널
    • /
    • 제28권5호
    • /
    • pp.389-395
    • /
    • 1999
  • 냉동공조설비, 발전설비, 화학플랜트설비 등에 사용되는 응축기는 주로 증기가 관의 외부에서 응축을 하고 냉각수가 관 내부로 흐르는 쉘-튜브(shell and tube)형 태를 취하고 있다. 초기투자비용 및 운전비용을 줄이기 위해서는 응축기의 열교환 성능을 향상시키는 일이 필수적이며 이를 위해 코팅 표면(coated surfaces), 거친 표면(rough surfaces), 코일 튜브(coiled tubes), 선회 흐름장치(swirl flow), 전열면적을 넓힌 낮은 핀관과 3차원 형상을 갖는 열전달 촉진관의 사용이 제시되고 있다.

  • PDF

Numerical Predictions of Heat Transfer in the Fluidized Bed Heat Exchanger

  • Ahn, Soo-Whan
    • 농업생명과학연구
    • /
    • 제44권4호
    • /
    • pp.29-43
    • /
    • 2010
  • The numerical analysis by using CFX 11.0 commercial code was done for proper design of the heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the characteristics of fluid flow, heat transfer and cleaning effect in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which a variety of solid particles such as glass ($3mm{\Phi}$), aluminum ($2{\sim}3mm{\Phi}$), steel ($2{\sim}2.5mm{\Phi}$), copper ($2.5mm{\Phi}$) and sand ($2{\sim}4mm{\Phi}$) were used in the fluidized bed with a smooth tube. Seven different solid particles have the same volume, and the effects of various parameters such as water flow rates, particle diameter, materials and geometry were investigated. The present experimental and numerical results showed that the flow velocity range for collision of particles to the tube wall was higher with heavier density solid particles, and the increase in heat transfer was in the order of sand, copper, steel, aluminum, and glass. This behavior might be attributed to the parameters such as surface roughness or particle heat capacity.

3중관 튜브형 잠열 축열조에서의 열전달 특성 연구 (Heat transfer characteristics of Triple-Tube Type Latent Heat Storage Tank)

  • 이욱균;한귀영;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.71-82
    • /
    • 2001
  • The heat transfer experiment in a latent heat storage tank as a solar energy storage system for the hot water supply was carried out. The latent heat storage tank was consisted of triple - tube type ; Outer shell for hot water from solar collector, PCM storage vessel in the middle of the tank and inside tube for hot water recovery. The heat storage tank has the dimension of 60 cm long and 34 cm outside diameter. Paraffin wax(m.p = 55.4C) and sodium acetate trihydrate(m.p = 58 C) were employed as the PCM this study. Experimental variables were inlet temperature and flow rate of the hot water for heat storage stage and cold water for heat recovery stage. Temperature profiles, heat transfer coefficient and the efficiency of heat storage$(Q/Q_{max})$ and heat recovery $(Q/Q_{max})$ were determined for the paraffin wax and inorganic salt respectively.

  • PDF

Refined finite element modelling of circular CFST bridge piers subjected to the seismic load

  • Faxing Ding;Qingyuan Xu;Hao Sun;Fei Lyu
    • Computers and Concrete
    • /
    • 제33권6호
    • /
    • pp.643-658
    • /
    • 2024
  • To date, shell-solid and fibre element model analysis are the most commonly used methods to investigate the seismic performance of concrete-filled steel tube (CFST) bridge piers. However, most existing research does not consider the loss of bearing capacity caused by the fracture of the outer steel tube. To fill this knowledge gap, a refined finite element (FE) model considering the ductile damage of steel tubes and the behaviour of infilled concrete with cracks is established and verified against experimental results of unidirectional, bidirectional cyclic loading tests and pseudo-dynamic loading tests. In addition, a parametric study is conducted to investigate the seismic performance of CFST bridge piers with different concrete strength, steel strength, axial compression ratio, slenderness ratio and infilled concrete height using the proposed model. The validation shows that the proposed refined FE model can effectively simulate the residual displacement of CFST bridge piers subjected to highintensity earthquakes. The parametric analysis indicates that CFST piers hold sufficient strength reserves and sound deformation capacity and, thus, possess excellent application prospects for bridge construction in high-intensity areas.

열수축을 하는 필라멘트 와인딩 복합재료 관의 설계 (Design of Filament Wound Composite Tubes under Thermal Contraction)

  • 정태은;신효철
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2407-2417
    • /
    • 1993
  • Thermal deformations and stresses due to temperature changes are the serious problems in cryogenic structures such as the torque tube in a superconducting generator, In this paper, the equations of thermal expansion coefficients expressed only by material properties and winding angles are derived for the filament wound composite tubes. The experimental results of thermal contraction of CFRP tubes are compared with those from theoretical approach. Composite tubes with optimally regulated thermal expansion coefficient are designed on the basis of the study for the torque tube in the superconducting generator with temperature distributions varying from 300K to 4.2 K. The filament winding angle of composites resisting thermal stresses properly is sought by the finite element method using layered shell elements. The results show that the composite tubes designed for the requirements in cryogenic environments can effectively cope with the thermal stress problem.

딤플 튜브형 EGR Cooler 구조건전성 및 열효율 평가 (Evaluation of Structural Integrity and Heat Exchange Efficiency for Dimpled Tube Type EGR Cooler)

  • 서영호;이현민;박중원;구태완;김정;강범수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.554-559
    • /
    • 2008
  • Most of vehicle manufacturers have applied exhaust gas recirculation (EGR) system to the development of diesel engines in order to obtain the high thermal efficiency without $NO_X$ and Particulate Matter (PM) emitted from the engine. EGR system, which reflow a cooled exhaust gas from vehicles burning diesel as fuel to a combustion chamber of engine, has been used to solve this problem. In order to confirm the safety of the EGR system, finite element analysis was carried out. The safety of EGR system against temperature variation in the shell and tubes was evaluated through the thermal and structural analysis, and the modal analysis using ANSYS was also performed. Finally, the performance of EGR system was verified through the experiment and numerical simulation using effectiveness-NTU method. Program for the estimation of the heat exchange efficiency of the EGR system with regard to the dimpled tube shape was developed.

  • PDF

Modeling of an Once Through Helical Coil Steam Generator of a Superheated Cycle for Sizing Analysis

  • Kim, Yeon-Sik;Sim, Yoon-Sub;Kim, Eui-Kwang
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.558-563
    • /
    • 1997
  • A thermal sizing code, named as HSGSA (Helical coil Steam Generator Sizing Analyzer), for a sodium heated helical coil steam generator is developed for KALIMER (Korea Advanced LIquid MEtal Reactor) design. The theoretical modeling of the shell and tube sides is described and relevant correlations are presented. For assessment of HSGSA, a reference plant design case is compared to the calculational outputs from HSGSA simulation.

  • PDF

바이오가스용 소형 열교환기 연구 (Compact Heat Exchanger Design for Biogas Application)

  • 이택홍;김태완;박태성;강영진;노재현
    • 한국수소및신에너지학회논문집
    • /
    • 제25권2호
    • /
    • pp.183-190
    • /
    • 2014
  • Our lab designs a heat exchangers for air and carbondioxide gas. Coolant is water, thus it is very difficult to determine heat transfer parameters in this gas-liquid system. Repeated experiments gives overdesign value 35%, overall heat transfer coefficient $33.8(kcal/m2-hr-^{\circ}C)$ for carbondioxide. Another series of experiments determine overdesign 18.7%, overall heat transfer coefficient $21.4(kcal/m2-hr-^{\circ}C)$ for Air. These parameters are in same range of literature. Overdesign is increasing as tube length increases, also increases as wall thickness of heat exchanger increases. To get proper fluid linear velocity in heat exchanger, we change the diameter of tube and finally we can have optimum fluid linear velocity in the heat exchanger.

전기장하에서의 비등 열전달 촉진에 관한 실험적 연구 (An experimental study for boiling heat transfer enhancement under electric fields)

  • 오시덕;곽호영
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2298-2314
    • /
    • 1996
  • Electric field effect on boiling of refrigerants R11, R113, and FC72 has been investigated experimentally. One purpose of the experimental investigation is to determine the effects of the electrode arrangements on electrohydrodynamic boiling of the above mentioned liquids. The test equipment employed in the experiment consists of a shell and tube heat exchanger with six or six and twelve rows of electrode wires around the tube. It has been found that the applied voltage promotes the boiling heat transfer coefficient except FC72. Boiling heat transfer enhancement obtained is about 230% for R11, 280% for R113. It has also been observed that bubbles detached from the tube aggregate at the place where the electrical gradient force balances with the buoyancy one. These aggregated bubbles force to decrease the boiling heat transfer coefficient as well as to reduce the voltage needed to the dielectric breakdown.

A cylindrical shell model for nonlocal buckling behavior of CNTs embedded in an elastic foundation under the simultaneous effects of magnetic field, temperature change, and number of walls

  • Timesli, Abdelaziz
    • Advances in nano research
    • /
    • 제11권6호
    • /
    • pp.581-593
    • /
    • 2021
  • This model is proposed to describe the buckling behavior of Carbon Nanotubes (CNTs) embedded in an elastic medium taking into account the combined effects of the magnetic field, the temperature, the nonlocal parameter, the number of walls. Using Eringen's nonlocal elasticity theory, thin cylindrical shell theory and Van der Waal force (VdW) interactions, we develop a system of partial differential equations governing the buckling response of CNTs embedded on Winkler, Pasternak, and Kerr foundations in a thermal-magnetic environment. The pre-buckling stresses are obtained by applying airy's stress function and an adjacent equilibrium criterion. To estimate the nonlocal critical buckling load of CNTs under the simultaneous effects of the magnetic field, the temperature change, and the number of walls, an optimization technique is proposed. Furthermore, analytical formulas are developed to obtain the buckling behavior of SWCNTs embedded in an elastic medium without taking into account the effects of the nonlocal parameter. These formulas take into account VdW interactions between adjacent tubes and the effect of terms involving differences in tube radii generally neglected in the derived expressions of the critical buckling load published in the literature. Most scientific research on modeling the effects of magnetic fields is based on beam theories, this motivation pushes me to develop a cylindrical shell model for studying the effect of the magnetic field on the static behavior of CNTs. The results show that the magnetic field has significant effects on the static behavior of CNTs and can lead to slow buckling. On the other hand, thermal effects reduce the critical buckling load. The findings in this work can help us design of CNTs for various applications (e.g. structural, electrical, mechanical and biological applications) in a thermal and magnetic environment.