• 제목/요약/키워드: Shear strengthening

검색결과 375건 처리시간 0.024초

탄소섬유시트를 사용한 철근콘크리트 구조물의 휨 보강에 관한 실험적 연구 (An Experimental Study on Flexural Repair of Reinforced Concrete Beams with the CFRP Sheet)

  • 박정원;박상렬;민창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.781-786
    • /
    • 2000
  • This paper presents the behavior and strenghening effect of reinforced concrete rectangular beams strengthened sing CFRP sheets with different strengthening level. In general, normally strengthened beams are failed by interfacial shear failure (delamination) within concrete, instead of by tensile failure of the CFRP sheets. The delamination occurred suddenly and the concrete cover cracked vertically by flexure was spalled off due to the release energy. The ultimate load considerably increased with an increase of strengthening level, while the ultimate deflection significantly decreased. The tensile force of CFRP sheets and average shear stress of concrete at delamination failure were curvilinearly proportional to the strengthening level. Therefore, the increment of ultimate load obtained by strengthening was curvilinearly proportional to th strengthening level.

  • PDF

강섬유 보강계수를 고려한 전단보강 되지 않은 SFRC 보의 전단내력 평가 (Evaluation of Shear Strength in SFRC Beam without Stirrups Considering Steel Fiber Strengthening Factor)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권2호
    • /
    • pp.213-220
    • /
    • 2004
  • 본 연구의 목적은 전단 보강근이 없는 강섬유 보강 콘크리트 보의 전단내력을 강섬유 계수를 이용하여 평가하기 위한 것이다. 이를 위하여 재료 및 부재 수준의 2단계 연구를 수행하였다. 기존 및 본 연구 결과에 의하면, 강섬유 보강 콘크리트의 주요 요인은 강섬유 계수로 평가되었으며, 이를 근거로 한 강섬유 보강계수가 제안되었다. 또한 기 제안된 전단내력식을 평가한 결과, 신성우 제안식이 강섬유 비보강 보의 내력을 적절히 평가하는 것으로 나타났다. 따라서 신성우 제안식에 강섬유 계수를 곱한 강섬유 보강 콘크리트의 전단내력식이 회귀분석에 의하여 제안되었다.

Experimental investigation on optimal shear strengthening of RC beams using NSM GFRP bars

  • Ramezanpour, M.;Morshed, R.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • 제67권1호
    • /
    • pp.45-52
    • /
    • 2018
  • Several techniques have been developed for shear strengthening of reinforced concrete (RC) members by using fiber reinforced polymer (FRP) composites. However, debonding of FRP retrofits from concrete substrate still deemed as a challenging concern in their application which needs to be scrutinized in details. As a result, this paper reports on the results of an experimental investigation on shear strengthening of RC beams using near surface mounted (NSM) FRP reinforcing bars. The main objective of the experimentation was increasing the efficiency of shear retrofits by precluding/postponing the premature debonding failure. The experimental program was comprised of six shear deficient RC beams. The test parameters include the FRP rebar spacing, inclination angle, and groove shape. Also, an innovative modification was introduced to the conventional NSM technique and its efficiency was evaluated by experimental observation and measurement. The results testified the efficiency of glass FRP (GFRP) rebars in increasing the shear strength of the test specimens retrofitted using conventional NSM technique. However, debonding of FRP bars impeded exploiting all retrofitting advantages and induced a premature shear failure. On the contrary, application of the proposed modified NSM (MNSM) technique was not only capable of preventing the premature debonding of FRP bars, but also could replace the failure mode of specimen from the brittle shear to a ductile flexural failure which is more desirable.

유리섬유보강재를 이용한 Deep Beam의 전단보강에 관한 실험적 연구 (An Experimental Study on Shear Strengthening of Concrete Deep Beams with Glass Fiber Sheets)

  • 조병완;김영진;김도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.609-614
    • /
    • 1997
  • Recently, many researchers have performed R&D about strengthening of R/C with steel plates, carbon fiber sheets. aramid fiber sheets and glass fiber sheets, and so on. However most of research were limited in study of flexural strengthening of R/C beams. This paper shows the results of an experimental study on shear reinforcement of deep beams using Glass Fiber Sheet in relation to shear-span ratio. strengthening orientation and anchorage. The results prove that shear failure is governed by reinforced orientation. adherence and anchorage. Additional anchorage of fibers does not only cause the improvement in the internal resistance, but also control the brittle shear failure of specimen after reaching the maximum load.

  • PDF

Parametric study of shear strength of CFRP strengthened end-web panels

  • Shalaby, Haitham A.;Hassan, Maha M.;Safar, Sherif S.
    • Steel and Composite Structures
    • /
    • 제31권2호
    • /
    • pp.159-172
    • /
    • 2019
  • Strengthening of civil infrastructure with advanced composites have recently become one of the most popular methods. The use of Fiber Reinforced Polymer (FRP) strips plates and fabric for strengthening of reinforced concrete structures has well established design guidelines and standards. Research on the application of FRP composites to steel structures compared to concrete structures is limited, especially for shear strengthening applications. Whereas, there is a need for cost-effective system that could be used to strengthen steel high-way bridge girders to cope with losses due to corrosion in addition to continuous demands for increasing traffic loads. In this study, a parametric finite element study is performed to investigate the effect of applying thick CFRP strips diagonally on webs of plate girders on the shear strength of end-web panels. The study focuses on illustrating the effect of several geometric parameters on nominal shear strength. Hence, a formula is developed to determine the enhancement of shear strength gained upon the application of CFRP strips.

Strengthening of isolated square footings using passive wrapping systems

  • Lu, Xingji;Aboutaha, Riyad S.
    • Computers and Concrete
    • /
    • 제27권1호
    • /
    • pp.41-54
    • /
    • 2021
  • This paper introduced three new strengthening systems for isolated footings: BFRP wrapping system, CFRP wrapping system, and steel jacketing system. The proposed systems are more practical than the current traditional methods, which involves installing many dowel bars and splicing reinforcing steels to join new and old concrete segments. In the proposed three new systems, BFRP wraps, CFRP wraps, or steel jackets are installed on the exterior surface of the enlarged footing, with construction adhesive or a few steel dowels being applied to the contact surfaces. To investigate the effectiveness of three systems, forty-four models were constructed in ABAQUS, with different parameters being considered. All footings investigated failed in punching shear, including original and retrofitted footings. According to FEA results and parametric studies, the three strengthening systems were capable of improving the punching shear resistance of footings. By introducing a new factor η, the punching shear equation in Eurocode 2 was modified to predict the punching shear resistances of the strengthened footings. A linear formula was developed to present the relationship between the new factor η and the investigated parameters.

전단보강비에 따른 FRP 쉬트의 전단보강성능 (Shear Strengthening Effect of RC Beams with FRP Sheets with respect to Shear Reinforcement Ration)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.68-71
    • /
    • 2004
  • In the shear strengthening with FRP sheets, beams are wrapped around the webs and tension face of critical shear span by fiber sheets. The shear strength of RC beam strengthened with FRP sheets must be calculated based on the effective strain that can be developed in the FRP sheets at ultimate stage because the final failure modes of beams are governed by premature debonding of FRP sheet due to the limitation of bonded length by beam depth. An experimental study is carried out to evaluate the shear strengthening effect of AFRP or GFRP sheets with respect to shear reinforcement ratio of rebar. From the test results, it was found that the additional shear strength provided by GFRP or AFRP can be estimated by $p_w{\cdot}f_w$ based on the maximum effective strain of FRP sheet $4,000m{\mu}$ proposed by ACI 440 committee.

  • PDF

Shear-Strengthening of Reinforced & Prestressed Concrete Beams Using FRP: Part I - Review of Previous Research

  • Ary, Moustapha Ibrahim;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권1호
    • /
    • pp.41-47
    • /
    • 2012
  • Fiber-Reinforced Polymers (FRP) are used to enhance the behavior of structural components in either shear or flexure. The research conducted in this paper was mainly focused on the shear-strengthening of reinforced and prestressed concrete beams using FRP. The main objective of the research was to identify the parameters affecting the shear capacity provided by FRP and evaluate the accuracy of analytical models. A review of prior experimental data showed that the available analytical models used to estimate the added shear capacity of FRP struggle to provide a unified design equation that can predict accurately the shear contribution of externally applied FRP. In this study, the ACI 440.2R-$08^1$ model and the model developed by Triantafillou and Antonopoulos$^2$ were compared with the prior experimental data. Both analytical models failed to provide a satisfactory prediction of the FRP shear capacity. This study provides insights into potential reasons for the unsatisfactory prediction.

Carbon FRP Grid로 휨 보강한 철근콘크리트 슬래브의 파괴형태와 설계기준 (Failure Mode and Design Guideline for Reinforced Concrete Slab Strengthened Using Carbon FRP Grid)

  • 박상렬;최현
    • 콘크리트학회논문집
    • /
    • 제16권5호
    • /
    • pp.667-675
    • /
    • 2004
  • 본 논문은 CFRP 격자 보강재로 보강한 콘크리트 슬래브의 파괴형태와 보강설계기준에 대한 연구이다. 실험 연구에서 채택한 시험변수로는 CFRP 격자 보강재의 양, 보강 모르타르의 깊이, 앵커핀의 유무, 압축부 보강 등이다. 연구에 의하면 CFRP 격자 섬유 보강량에 따라 파괴형태가 다르게 나타났는데 낮은 보강수준에서는 FRP 격자의 인장 파단파괴를 보였고 보통의 보강정도에서는 격자층 계면전단파괴가 발생하였다. 높은 보강량을 가진 슬래브에서는 사인장전단파괴 형태를 나타냈다. 보강 효과는 FRP 격자 보강재의 양이 증가할수록 증대하였으나 취성 전단파괴에 의해 연성은 감소되었다. 따라서 FRP 격자 보강량을 제한함으로써 갑자기 하중 지지력을 상실하는 전단파괴를 피할 수 있다. 파괴형태 중 CFRP 파단파괴가 바람직한데 그 이유는 섬유파단 후에도 극한상태에서 보강 전 슬래브의 하중지지력과 연성을 가지고 있기 때문이다. 마지막으로 본 논문은 CFRP 격자섬유보강설계기준과 과정을 제시하고 있다.

강섬유 보강 기둥의 강도 및 변형 특성 (Strength and Deformation Characteristics of Steel Fiber Reinforced Columns)

  • 장극관;이현호;양승호
    • 콘크리트학회논문집
    • /
    • 제14권1호
    • /
    • pp.49-57
    • /
    • 2002
  • 합성재료중 강섬유(Steel fiber)로 보강된 콘크리트는 보강되지 않은 콘크리트에 비하여 전단, 휨, 피로강도 증진 및 균열제어 효과가 우수한 것으로 평가되고 있다. 특히 전단에 대한 강섬유 보강효과는 취성적인 전단파괴에서의 안정적인 휨 파괴로의 파괴 양상 변화를 보이는 것으로 보고되고 있다. 따라서, 본 연구에서는 기존연구결과 및 총 10개의 실험체를 대상으로 철근콘크리트 기둥에 대한 강섬유의 전단보강 효과를 평가하였다. 실험결과, 강섬유 혼입율 1.5 %에서 전단강도 증진효과가 가장 우수한 것으로 평가되었으며, 연성능력의 증진도 우수한 것으로 평가되었다. 그러나, 강도 및 연성능력 증진에 비하여 강성 및 에너지 소산 능력에 대한 강섬유 보강효과는 다소 미흡한 것으로 평가되었다.