• 제목/요약/키워드: Shear strength

검색결과 5,585건 처리시간 0.038초

비닐하우스 기초 토양의 다짐률 변화에 따른 전단강도 특성 (Experimental Evaluation of Shear Strength of Surface Soil Beneath Greenhouse Varying Compaction Rate)

  • 임성윤;허기석;곽동엽
    • 한국농공학회논문집
    • /
    • 제63권6호
    • /
    • pp.17-26
    • /
    • 2021
  • Greenhouses have been damaged due to the uplift pressure from strong wind, for which rebar piles are often installed near the greenhouse to resist the pressure. For the effective design of rebar piles, it is necessary to access the shear strength of soil on which the greenhouse is constructed. This study experimentally evaluates the shear strength of the soil beneath the greenhouse. Four soil samples were collected from four agricultural sites, and prepared for testing with 75, 80, 85, and 90% compaction rates. One-dimensional unconfined compression test (UC), consolidated-undrained triaxial test (CU), and resonant column test (RC) were performed for the evaluation of shear strength and shear modulus. Generally, the higher shear strength and modulus were observed with the higher compaction rates. In particular, the UC shear strength increases with the increase of #200 sieve passing rate. Resulting from the CU test, the sample with the most of coarse soil had the highest friction angle, but the variation is small among samples. Resulting from the CU and RC tests, the ratio of maximum shear modulus with the major principle stress at failure was the higher at the finer soil. The ratio was two to three times greater than the ratio from the standard sand. This indicates that the shear strength is lower for the fine soil than the coarse soil at the same shear modulus. The results of this study will be a useful resource for the estimation of the pull-out strength of the rebar pile against the uplift pressure.

Analytical model for flexural and shear strength of normal and high-strength concrete beams

  • Campione, Giuseppe
    • Structural Engineering and Mechanics
    • /
    • 제78권2호
    • /
    • pp.199-207
    • /
    • 2021
  • In the present paper, an analytical model is proposed to determine the flexural and shear strength of normal and high-strength reinforced concrete beams with longitudinal bars, in the presence of transverse stirrups. The model is based on evaluation of the resistance contribution due to beam and arch actions including interaction with stirrups. For the resistance contribution of the main bars in tension the residual bond adherence of steel bars, including the effect of stirrups and the crack spacing of R.C. beams, is considered. The compressive strength of the compressed arch is also verified by taking into account the biaxial state of stresses. The model was verified on the basis of experimental data available in the literature and it is able to include the following variables in the resistance provision: - geometrical percentage of steel bars; - depth-to-shear span ratio; - resistance of materials; - crack spacing; - tensile stress in main bars; - residual bond resistance including the presence of stirrups;- size effects. Finally, some of the more recent analytical expressions able to predict shear and flexural resistance of concrete beams are mentioned and a comparison is made with experimental data.

석탄회 인공경량골재를 사용한 고강도 콘크리트 보의 전단성능 (Shear Performance of High-Strength Reinforced Concrete Beams using Fly-Ash Artificial Lightweight Aggregate)

  • 정수영;윤현도;박완신
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.233-242
    • /
    • 2002
  • This study is to investigate experimentally the shear capacity of high-strength lightweight-aggregate reinforced concrete beams subjected to monotonic loading. Ten beams made of fly-ash artificial lightweight high-strength concrete were tested to determine their diagonal cracking and ultimate shear capacities. The variables in the test program were longitudinal reinforcement ratio; which variabled (between 0.83 and 1.66 percent), shear span-to-depth ratio (a/d=1.5, 2.5 and 3.5), and web reinforcement(0, 0.137, 0.275 and 0.554 percent). Six of the test beams had no web reinforcement and the other six had web reinforcement along the entire length of the beam. Most of beams failed brittly by distinct diagonal shear crack, and have reserved shear strength due to the lack of additional resisting effect by aggregate interlocking action after diagonal cracking. Test results indicate that the ACI Building Code predictions of Eq. (11-3) and (11-5) for lightweight concretes are unconservative for beams with tensile steel ratio of 1.66, a/d ratios greater than 2.5 without web reinforcement. Through a more rational approach to compute the contribution of concrete to the shear capacity, a postcracking shear strength in concrete is observed.

화강풍화잔적토의 불포화전단강도에 미치는 순연직응력의 영향 (The Influence of Net Normal Stresses on the Shear Strength of Unsaturated Residual Granite Soils)

  • 성상규;이인모
    • 한국지반공학회논문집
    • /
    • 제19권2호
    • /
    • pp.27-38
    • /
    • 2003
  • 본 연구에서는 불포화토의 전단강도 특성과 이를 예측하는 모델에 대해 다루었다. 특히, 순연직응력(net normal stress)이 흙수분 특성곡선에 미치는 영향과 불포화토의 전단강도 발현에 미치는 영향에 대해 중점적으로 연구하였다. 이를 위해서 국내에 산재해 있는 화강풍화잔적토를 시료로 하여 불포화삼축압축 시험과 SWCC 시험 등을 실시하였으며, 특히, 순연직응력을 일정하게 유지시킨 상태에서 SWCC를 구할 수 있게 끔 기존의 장비를 개량하였다. 불포화토의 전단강도 시험결과와 기존의 강도예측모델에 의해 예측된 강도포락선을 비교해 본 결과, 흙수분 특성곡선과 흡인력 (matric suction)을 한 축으로 하는 강도포락선의 기울기가 순연직응력에 따라 변화함을 발견할 수 있었다. 따라서, 보다 정확하게 불포화토의 전단강도 포락선을 묘사하기 위해서는 흡인력에 미치는 순연직응력의 영향이 고려되어야 하는 것으로 나타났다. 본 논문에서는 기 언급한 내용에 근거하여 수정된 불포화토 전단강도 예측모델을 제안하였다.

Experimental study for application of the punch shear test to estimate adfreezing strength of frozen soil-structure interface

  • Park, Sangyeong;Hwang, Chaemin;Choi, Hangseok;Son, Youngjin;Ko, Tae Young
    • Geomechanics and Engineering
    • /
    • 제29권3호
    • /
    • pp.281-290
    • /
    • 2022
  • The direct shear test is commonly used to evaluate the shear behavior of frozen soil-structure interfaces under normal stress. However, failure criteria, such as the Mohr-Coulomb failure criterion, are needed to obtain the unconfined shear strength. Hence, the punch shear test, which is usually used to estimate the shear strength of rocks without confinement, was examined in this study to directly determine the adfreezing strength. It is measured as the shear strength of the frozen soil-structure interface under unconfined conditions. Different soils of silica sand, field sand, and field clay were prepared inside the steel and concrete ring structures. Soil and ring structures were frozen at the target temperature for more than 24 h. A punch shear test was then conducted. The test results show that the adfreezing strength increased with a decrease in the target temperature and increase in the initial water content, owing to the increase in ice content. The adfreezing strength of field clay was the smallest when compared with the other soil specimens because of the large amount of unfrozen water content. The field sand with the larger normalized roughness showed greater adfreezing strength than the silica sand with a lower normalized roughness. From the experiment and analysis, the applicability of the punch shear test was examined to measure the adfreezing strength of the frozen soil-structure interface. To find a proper sample dimension, supplementary experiments or numerical analysis will be needed in further research.

하프 PC판과 후타설콘크리트 접합면의 면내전단강도에 관한 실험적 연구 (An Experimental Study on In-Plane Shear Strength of the Interface between Half PC Plate and Cast-in-Place Concrete Plate)

  • 신동원;고만영;이동우;김용부
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.513-518
    • /
    • 1998
  • In Half Precast Concrete Method, such as composite slab and composite wall, Interface between half PC plate and cast-in-place concrete is occurred. And this interface endure lastly in-plane shear which is occurred by external force. Therefore, test was executed to study in-plane shear strength of interface between half PC plate and cast-in-place concrete. In this test, Experimental parameters are finishing condition of the interface, cohesion of concrete, existence and nonexistence of re-bar truss, and angle and direction of lattice of re-bar truss. Comparing and analyzing experimental results, conclusions are obtained as follows. (1) In-plane shear strength of wide interface in composite plate is more affected by the roughness of interface than re-bar truss. And cohesion of concrete contribute to increasing in-plane shear strength. Therefore it seems that the interface should be roughen and kept clean to improve in-plane shear strength. (2) It seems that shear friction equation in ACI code can be sagely available for design of in-plane shear of composite plate.

  • PDF

폴콘을 이용한 유류 오염 점토지반의 전단강도 예측 (Prediction of the Shear Strength of Oil Contaminated Clay using Fall Cone)

  • 송영우;이한석;박준범
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.107-113
    • /
    • 2010
  • This paper presents the prediction of shear strength of oil contaminated clay using fall cone test used to determine the liquid limit of soil. The penetration depth of fall cone is related to water content of soil. Laboratory vane shear can also be related to water content. To explore the relative correlation between penetration depth of fall cone and laboratory vane shear, both fall cone tests and laboratory vane shear test were carried out with water contents of soil. The developed empirical relationships in this studys showed that the shear strength is reduced to 3.9% with 1% increase of oil content. And, the lesser initial water content of contaminated clay, the more shear strength of contaminated clay is affected by oil content.

세장한 철근콘크리트 보의 병형기초 전단강도 모델 (Deformation-Based Shear Strength Model for Slender Reinforced Concrete Beams)

  • 최경규;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.391-394
    • /
    • 2005
  • A theoretical model was developed to predict the shear strength of slender reinforced concrete beams. The shear force applied to a cross-section of the beam was assumed to be resisted primarily by the compressive zone of intact concrete rather than by the tensile zone. The shear capacity of the cross section was defined based on the material failure criteria of concrete: failure controlled by compression and failure controlled by tension. In the evaluation of the shear capacity, interaction with the normal stresses developed by the flexural moment in the cross section was considered. In the proposed strength model, the shear strength of the beam and the location of the critical section were determined at the intersection between the shear capacity and shear demand curves. The proposed strength model was verified by the comparisons to prior experimental results.

  • PDF

콜드조인트 계면 처리방법에 따른 초고성능 콘크리트의 전단접착성능에 관한 실험적 연구 (An Experimental study on the bonding shear performance evaluation of UHPC accordance with adhesion surface treatment)

  • 김민성;이승엽;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.86-87
    • /
    • 2015
  • An active study on UHPC, which has been recently used in high-rise building and bridges, is in progress. However, research on bonding shear strength of UHPC is required to be studied due to the lack of information. In this study, experimental research progress for bonding shear strength (shear strength of adhesive surface) evaluation of UHPC (Ultra High Performance Concrete) is proceeded. First, specimens that surface treatment methods of concrete bonded section and retardation time of placement are considered are produced. Second, Direct Shear test is applied on concrete bonded section of UHPC. As a result of this study, the highest bonding shear strength specimen in which compared to the non-retardation time specimen is compaction turbulence treatment. From later study, it is judged that strength of UHPC in accordance with direction of steel fiber when steel fiber of UHPC is mixed.

  • PDF

FRP Bar를 사용한 고강도 콘크리트 보의 콘크리트 전단강도 (Concrete Shear Strength of High Strength Concrete Beams Reinforced with FRP Bars)

  • 윤형수;장희석;김희성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.287-290
    • /
    • 2005
  • This study evaluates the concrete shear strength for normal and high strength concrete beams reinforced with 3 type FRP bars (CFRP, GFRP, HFRP). Experimental results obtained from twenty-four simply supported concrete beams are compared with values predicted by FRP shear strength expressions proposed in the various literatures, including the ACI Committee 318 and ACI Committee440. The shear strength correction factors are proposed through the regression analysis.

  • PDF