• Title/Summary/Keyword: Shear span ratio

Search Result 362, Processing Time 0.024 seconds

Free Vibration Characteristics of Columns Immersed in Fluid with a Concentrated Mass at the Top (상단에 집중질량을 갖는 유체에 잠긴 기둥의 자유진동 특성)

  • 오상진
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.1
    • /
    • pp.105-112
    • /
    • 2000
  • This paper deals with the free vibrations of columns immersed in fluid. The column model is based on the classical Bernoulli-euler theory which neblects the effects of rotatory inerital and shear deformation. The eccentricity and rotatory inertial of the concentrated mass at the top are taken into accuont. In the governing equation for the free vibration of column, thedensity of immersed part was midified to account for theadded fluid mass. The govering differential equations are solved numerically using the corresponding boundary conditions. The lowest four natural frequencies and corresponding mode shapes are calculated over a range of non-dimensional system parameters ; the mas density ration of fluid to column, the ratio of fluid depth to span length, the ratio of tip mass to total column mass, the dimensionless mass moment of inertia, and the eccentricity.

  • PDF

Experimental study on flexural strength of modular composite profile beams

  • Ahn, Hyung-Joon;Ryu, Soo-Hyun
    • Steel and Composite Structures
    • /
    • v.7 no.1
    • /
    • pp.71-85
    • /
    • 2007
  • This study suggests modular composite profile beams, where the prefab concept is applied to existing composite profile beams. The prefab concept produces a beam of desired size having two types of profile: side module and bottom module. Module section will improve construction efforts because it offers several benefits : reduction of deflections due to creep and shrinkage, which might be found in existing composite profile beams; increase in span/depth ratio; and free prefabrication of any required beams. Based on the established analysis theory of composite profile beams, an analysis theory of modular composite profile beams was suggested, and analysis values were compared with experimental ones. The behavior of individual modules with increase of load was measured with a strain gauge, and the shear connection ratio between modules was analyzed by using the measured values. As a result of experiment, it was found that theoretical flexural strength on condition of full connection was 57%-80% by connection of modules for each specimen, and it is expected that flexural strength will approximate the theoretical levels through further module improvement.

Free Vibrations of Columns Immersed in Fluid (유체에 담긴 기둥의 자유진동)

  • 오상진;이병구;모정만
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.225-230
    • /
    • 1999
  • The purpose of this paper is to investigate the natural frequencies and mode shape of columns immersed in fluid. The beam model is based on the classical Bernoulli-Euler beam theory which neglects the effects of rotatory inertial and shear deformation. The eccentricity and rotatory inerital of the tip mass are taken into account . The governing differential equations forr the free vibrations of immersed columns are solved numerically using the corresponding boundary conditoins. The lowest four natural frequencies and corresponding mode shapes are calculated over a range of non-dimensional system parameters : the ratio of fluid depth to span length, the mass ratio, the dimensionless mass moment of inertial, and the eccentricity.

  • PDF

Experimental and analytical research on geopolymer concrete beams reinforced with GFRP bars

  • Suleyman Anil Adakli;Serkan Tokgoz;Sedat Karaahmetli;Cengiz Dundar
    • Structural Engineering and Mechanics
    • /
    • v.91 no.4
    • /
    • pp.335-347
    • /
    • 2024
  • This paper presents the behavior of geopolymer concrete beams reinforced with glass fiber reinforced polymer (GFRP) bars. In the study, ordinary Portland cement concrete and geopolymer concrete beams having GFRP bars were prepared and tested under four-point loading. The load-deflection diagrams and load capacities of the tested beams were obtained. It was observed that the tested beams exhibited good ductility and significant deflection capacity. The results showed that increasing the tension GFRP reinforcement ratio caused enhancement in the strength capacity of geopolymer concrete beams. In addition, the tested beams were analyzed to obtain the load capacity and the load-deflection responses. The theoretical load-deflection curves and load bearing capacities have been predicted well with the test results. Parametric study has been performed to determine the influences of concrete strength, shear span to depth ratio (a/d) and reinforcement ratio on the behavior of geopolymer concrete beams longitudinally reinforced with GFRP bars. It was concluded that increasing concrete strength led to an increase in load capacity. Besides, the ultimate load increased as the reinforcement ratio increased. On the other hand, increasing a/d ratio reduced the ultimate load value of GFRP reinforced geopolymer concrete beams.

Strength Evaluation for Doubly Reinforced Composite Beams with Steel Fiber Concretes and Steel Angles (강섬유 콘크리트와 형강을 사용한 합성 복근보의 강도 특성)

  • Oh, Young-Hun;Nam, Young-Gil;Lee, Jae-Yeon
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.755-763
    • /
    • 2008
  • The purpose of this study is to investigate the structural performance of doubly reinforced composite beams with steel fiber concretes and steel angles. For this purpose, total 6 specimens whose variables are shear span-to-depth ratio, existence of shear reinforcement, and shear reinforcement details, are made and tested. All specimens are constructed of steel fiber concretes with specified compressive strength of 30 MPa and steel fiber volumn content of 1%. From the experimental results, structural performance of doubly reinforced composite beams are evaluated in terms of strength, stiffness, ductility, and energy absorbing capacity. For the better structural performance, it is recommended that the composite beam is designed with diagonal shear reinforcement.

Accurate theoretical modeling and code prediction of the punching shear failure capacity of reinforced concrete slabs

  • Rajai Z. Al-Rousan;Bara'a R. Alnemrawi
    • Steel and Composite Structures
    • /
    • v.52 no.4
    • /
    • pp.419-434
    • /
    • 2024
  • A flat slab is a structural system where columns directly support it without the presence of beam elements. However, despite its wide advantages, this structural system undergoes a major deficiency where stresses are concentrated around the column perimeter, resulting in the progressive collapse of the entire structure as a result of losing the shear transfer mechanisms at the cracked interface. Predicting the punching shear capacity of RC flat slabs is a challenging problem where the factors contributing to the overall slab strength vary broadly in their significance and effect extent. This study proposed a new expression for predicting the slab's capacity in punching shear using a nonuniform concrete tensile stress distribution assumption to capture, as well as possible, the induced strain effect within a thick RC flat slab. Therefore, the overall punching shear capacity is composed of three parts: concrete, aggregate interlock, and dowel action contributions. The factor of the shear span-to-depth ratio (a_v/d) was introduced in the concrete contribution in addition to the aggregate interlock part using the maximum aggregate size. Other significant factors were considered, including the concrete type, concrete grade, size factor, and the flexural reinforcement dowel action. The efficiency of the proposed model was examined using 86 points of published experimental data from 19 studies and compared with five code standards (ACI318, EC2, MC2010, CSA A23.3, and JSCE). The obtained results revealed the efficiency and accuracy of the model prediction, where a covariance value of 4.95% was found, compared to (13.67, 14.05, 15.83, 19.67, and 20.45) % for the (ACI318, CSA A23.3, MC2010, EC2, and JSCE), respectively.

Simplified analytical Moment-Curvature relationship for hollow circular RC cross-sections

  • Gentile, Roberto;Raffaele, Domenico
    • Earthquakes and Structures
    • /
    • v.15 no.4
    • /
    • pp.419-429
    • /
    • 2018
  • The seismic vulnerability analysis of multi-span bridges can be based on the response of the piers, provided that deck, bearings and foundations remain elastic. The lateral response of an RC bridge pier can be affected by different mechanisms (i.e., flexure, shear, lap-splice or buckling of the longitudinal reinforcement bars, second order effects). In the literature, simplified formulations are available for mechanisms different from the flexure. On the other hand, the flexural response is usually calculated with a numerically-based Moment-Curvature diagram of the base section and equivalent plastic hinge length. The goal of this paper is to propose a simplified analytical solution to obtain the Moment-Curvature relationship for hollow circular RC sections. This based on calibrated polynomials, fitted against a database comprising 720 numerical Moment-Curvature analyses. The section capacity curve is defined through the position of 6 characteristic points and they are based on four input parameters: void ratio of the hollow section, axial force ratio, longitudinal reinforcement ratio, transversal reinforcement ratio. A case study RC bridge pier is assessed with the proposed solution and the results are compared to a refined numerical FEM analysis, showing good match.

Seismic performance of the concrete-encased CFST column to RC beam joints: Analytical study

  • Ma, Dan-Yang;Han, Lin-Hai;Zhao, Xiao-Ling;Yang, Wei-Biao
    • Steel and Composite Structures
    • /
    • v.36 no.5
    • /
    • pp.533-551
    • /
    • 2020
  • A finite element analysis (FEA) model is established to investigate the concrete-encased concrete-filled steel tubular (CFST) column to reinforced concrete (RC) beam joints under cyclic loading. The feasibility of the FEA model is verified by a set of test results, consisting of the failure modes, the exposed view of connections, the crack distributions and development, and the hysteretic relationships. The full-range analysis is conducted to investigate the stress and strain development process in the composite joint by using this FEA model. The internal force distributions of different components, as well as the deformation distributions, are analyzed under different failure modes. The proposed connections are investigated under dimensional and material parameters, and the proper constructional details of the connections are recommended. Parameters of the beam-column joints, including material strength, confinement factor, reinforcement ratio, diameter of steel tube to sectional width ratio, beam to column linear bending stiffness ratio and beam shear span ratio are evaluated. Furthermore, the key parameters affecting the failure modes and the corresponding parameters ranges are proposed in this paper.

Research on damage of solid-web steel reinforced concrete T-shaped columns subjected to various loadings

  • Xue, Jianyang;Zhou, Chaofeng;Liu, Zuqiang
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.409-423
    • /
    • 2017
  • This paper presents an experimental study on damage evolution laws of solid-web steel reinforced concrete (SRC) T-shaped columns along the direction of the web under various loadings. Ten specimens with a scale ratio of 1/2 and a shear span ratio of 2.5 were designed and fabricated. The influences of various parameters, including the axial compression ratio, steel ratio, and loading mode, were examined. The mechanical performances including load-displacement curve and energy dissipation capacity under the monotonic and low cyclic loadings were analyzed. Compared with the monotonic loading, bearing capacity, ultimate deformation capacity, and energy dissipation capacity of the specimens decrease to some extent with the increase of the displacement amplitude and the number of loading cycle. The results show that the damage process of the SRC T-shaped column can be divided into five stages, namely non-damage, slight-damage, steadily-developing-damage, severe-damage and complete-damage. Finally, based on the Park-Ang model, a modified nonlinear damage model which combines the maximum deformation with hysteretic energy dissipation is proposed by taking into account the dynamic influence of the aforementioned parameters. The results show that the modified model in this paper is more accurate than Park-Ang model and can better describe the damage evolution of SRC T-shaped columns.

3-D finite element modelling of prestressed hollow-core slabs strengthened with near surface mounted CFRP strips

  • Mahmoud, Karam;Anand, Puneet;El-Salakawy, Ehab
    • Computers and Concrete
    • /
    • v.21 no.6
    • /
    • pp.607-622
    • /
    • 2018
  • A non-linear finite element model (FEM) was constructed using a three-dimensional software (ATENA-3D) to investigate the effect of strengthening on the behavior of prestressed hollow-core (PHC) slabs with or without openings. The slabs were strengthened using near surface mounted (NSM)-carbon fiber reinforced polymer (CFRP) strips. The constructed model was validated against experimental results that were previously reported by the authors. The validated FEM was then used to conduct an extensive parametric study to examine the influence of prestressing reinforcement ratio, compressive strength of concrete and strengthening reinforcement ratio on the behavior of such slabs. The FEM results showed good agreement with the experimental results where it captured the cracking, yielding, and ultimate loads as well as the mid-span deflection with a reasonable accuracy. Also, an overall enhancement in the structural performance of these slabs was achieved with an increase in prestressing reinforcement ratio, compressive strength of concrete, external reinforcement ratio. The presence of openings with different dimensions along the flexural or shear spans reduced significantly the capacity of the PHC slabs. However, strengthening these slabs with 2 and 4 (64 and $128mm^2$ that represent reinforcement ratios of 0.046 and 0.092%) CFRP strips was successful in restoring the original strength of the slab and enhancing post-cracking stiffness and load carrying capacity.