• 제목/요약/키워드: Shear capacity

검색결과 1,901건 처리시간 0.031초

Assessment of shear resistance of corroded beams repaired using SFRC in the tension zone

  • Jongvivatsakul, Pitcha;Laopaitoon, Phattarakan;Nguyen, Yen T.H.;Nguyen, Phuoc T.;Bui, Linh V.H.
    • Computers and Concrete
    • /
    • 제27권5호
    • /
    • pp.395-406
    • /
    • 2021
  • This study experimentally and analytically investigates the shear behavior of corroded reinforced concrete (RC) beams repaired using steel fiber-reinforced concrete (SFRC) in the flexural zone. The experimental parameters are the corrosion degree (0%, 12%, and 17%) and the steel fiber volume in the SFRC (1.0%, 1.5%, and 2.0%). The test results reveal that corrosion degree significantly affects the shear resistance of the beams. The shear capacity of the beam with the corrosion degree of 17% was higher than that of the uncorroded beam, whereas the shear capacity of the beam with the corrosion degree of 12% was lower than that of the uncorroded beam. The shear efficiency of damaged beams can be recovered by repairing them using SFRC that contains a reasonable amount of steel fibers. In addition, two methods to estimate the shear capacity of the repaired beams are developed using the modified truss analogy and strut-and-tie models. The estimated shear capacity of the beam using the modified truss analogy model agrees well with the experimental data.

Prediction of shear strength and drift capacity of corroded reinforced concrete structural shear walls

  • Yang, Zhihong;Li, Bing
    • Structural Engineering and Mechanics
    • /
    • 제83권2호
    • /
    • pp.245-257
    • /
    • 2022
  • As the main lateral load resisting system in high-rise reinforced concrete structures, the mechanical performance of shear wall has a significant impact on the structure, especially for high-rise buildings. Steel corrosion has been recognized as an important factor affecting the mechanical performance and durability of the reinforced concrete structures. To investigate the effect on the seismic behaviour of corroded reinforced concrete shear wall induced by corrosion, analytical investigations and simulations were done to observe the effect of corrosion on the ultimate seismic capacity and drift capacity of shear walls. To ensure the accuracy of the simulation software, several validations were made using both non-corroded and corroded reinforced concrete shear walls based on some test results in previous literature. Thereafter, a parametric study, including 200 FE models, was done to study the influence of some critical parameters on corroded structural shear walls with boundary element. These parameters include corrosion levels, axial force ratio, aspect ratio, and concrete compressive strength. The results obtained would then be used to propose equations to predict the seismic resistance and drift capacity of shear walls with various corrosion levels.

확공형 마이크로 파일의 강도 평가에 관한 연구 (A Study on the Strength Evaluation of Micropile with Expanded Drill Hole)

  • 이재민;김두환
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.74-81
    • /
    • 2014
  • This study proposes an advanced type of a micropile system. The proposed micropile system consists of perfobond ribs installed steel rod to improve shear capacity between the thread and the grout, and partially expanded drill holes to increase resistance capacity between the grout and the ground. This study contains experimental evaluations on the proposed micropile system to verify the shear capacity of perfobond rib installed on the steel rod and the load-carrying capacity of shear key created by the partially expanded drill hole. Push-out tests were conducted on a rolled screw thread and steel rods which perfobond ribs are installed instead of rolled screw, in order to compare their load-carrying capacity and behavioral characteristics. As a result, it was confirmed that the perfobond-rib steel rods show much superior structural behavior in terms of initial stiffness, ultimate load, and ductile behavior.

합성 지하벽의 전단내력 산정에 관한 실험적 연구 (Experimental Study on the Shear Capacity of Composite Basement Walls)

  • 김성만;이성호;서수연;이리형;홍원기;장재호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.379-384
    • /
    • 2001
  • This paper presents the experimental result of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector. Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, arrangement of shear connector, thickness of wall, shear span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

  • PDF

Shear-Strengthening of Reinforced & Prestressed Concrete Beams Using FRP: Part I - Review of Previous Research

  • Ary, Moustapha Ibrahim;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권1호
    • /
    • pp.41-47
    • /
    • 2012
  • Fiber-Reinforced Polymers (FRP) are used to enhance the behavior of structural components in either shear or flexure. The research conducted in this paper was mainly focused on the shear-strengthening of reinforced and prestressed concrete beams using FRP. The main objective of the research was to identify the parameters affecting the shear capacity provided by FRP and evaluate the accuracy of analytical models. A review of prior experimental data showed that the available analytical models used to estimate the added shear capacity of FRP struggle to provide a unified design equation that can predict accurately the shear contribution of externally applied FRP. In this study, the ACI 440.2R-$08^1$ model and the model developed by Triantafillou and Antonopoulos$^2$ were compared with the prior experimental data. Both analytical models failed to provide a satisfactory prediction of the FRP shear capacity. This study provides insights into potential reasons for the unsatisfactory prediction.

세장한 철근콘크리트 보의 병형기초 전단강도 모델 (Deformation-Based Shear Strength Model for Slender Reinforced Concrete Beams)

  • 최경규;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.391-394
    • /
    • 2005
  • A theoretical model was developed to predict the shear strength of slender reinforced concrete beams. The shear force applied to a cross-section of the beam was assumed to be resisted primarily by the compressive zone of intact concrete rather than by the tensile zone. The shear capacity of the cross section was defined based on the material failure criteria of concrete: failure controlled by compression and failure controlled by tension. In the evaluation of the shear capacity, interaction with the normal stresses developed by the flexural moment in the cross section was considered. In the proposed strength model, the shear strength of the beam and the location of the critical section were determined at the intersection between the shear capacity and shear demand curves. The proposed strength model was verified by the comparisons to prior experimental results.

  • PDF

지진하중을 받는 철근콘크리트 원형교각의 전단성능곡선 모델 (Shear Capacity Curve Model for Circular RC Bridge Columns under Seismic Loads)

  • 이재훈;고성현;정영수
    • 한국지진공학회논문집
    • /
    • 제10권2호
    • /
    • pp.1-10
    • /
    • 2006
  • 형상비가 상대적으로 작은 철근콘크리트 교각에 지진작용으로 인한 반복 횡하중이 작용하면 초기단계와 중간단계의 변위에서는 휨 거동을 보이다가 최종변위단계에서는 전단에 의해 파괴되는 휨-전단 거동을 보인다. 휨-전단 파괴거동을 보이는 교각은 휨 파괴거동을 보이는 교각에 비하여 연성능력이 저하되므로, 내진설계 또는 내진성능평가에서 극한변위를 해석적으로 결정하기 위해서는 휨성능곡선과 함께 전단성능곡선 모델을 적용하여야 한다. 본 논문에서는 원형교각에 대한 기존 모델을 수정한 전단성능곡선 모델을 제안하였고, CALTRANS 모델, Aschheim등의 모델, Priestley 등의 모델, 제안모델의 특징을 비교하였다. 또 국내에서 수행된 실물크기 기둥 실험체를 대상으로 전단성능곡선 모델을 평가하였다. 제한된 범위의 소수 실험결과에 대한 적용으로서 일반화하기는 어려울 것이지만, 실험결과와 비교 검토한 결과 제안모델이 파괴형태의 예측과 변위성능 예측의 정확도에서 매우 우수한 것으로 평가되었다.

Experimental Study on Low Cyclic Loading Tests of Steel Plate Shear Walls with Multilayer Slits

  • Lu, Jinyu;Yu, Shunji;Qiao, Xudong;Li, Na
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1210-1218
    • /
    • 2018
  • A new type of earthquake-resisting element that consists of a steel plate shear wall with slits is introduced. The infill steel plate is divided into a series of vertical flexural links with vertical links. The steel plate shear walls absorb energy by means of in-plane bending deformation of the flexural links and the energy dissipation capacity of the plastic hinges formed at both ends of the flexural links when under lateral loads. In this paper, finite element analysis and experimental studies at low cyclic loadings were conducted on specimens with steel plate shear walls with multilayer slits. The effects caused by varied slit pattern in terms of slit design parameters on lateral stiffness, ultimate bearing capacity and hysteretic behavior of the shear walls were analyzed. Results showed that the failure mode of steel plate shear walls with a single-layer slit was more likely to be out-of-plane buckling of the flexural links. As a result, the lateral stiffness and the ultimate bearing capacity were relatively lower when the precondition of the total height of the vertical slits remained the same. Differently, the failure mode of steel plate shear walls with multilayer slits was prone to global buckling of the infill steel plates; more obvious tensile fields provided evidence to the fact of higher lateral stiffness and excellent ultimate bearing capacity. It was also concluded that multilayer specimens exhibited better energy dissipation capacity compared with single-layer plate shear walls.

단속배치된 캡 형상의 전단연결재의 전단내력에 관한 실험 연구 (Experimental Study on the Shear Capacity of Cap-Type Shear Connectors With Constant Intervals)

  • 오명호;이민석;김영호;김명한
    • 한국공간구조학회논문집
    • /
    • 제18권2호
    • /
    • pp.121-128
    • /
    • 2018
  • The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the cap-type shear connectors with constant intervals. Existing equations for the evaluation of shear connector strength have been investigated on the basis of test results. The reinforcing bars for longitudinal reinforcement and the penetrative bars for transverse reinforcement didn't have much effect on the shear capacity of the cap-type shear connector. The larger the width of cap-type shear connector was profiled, the greater the shear strength turned. The shear capacities of cap-type shear connectors with constant intervals were evaluated on the basis of push-out test results, and those were possible to be determined with proper safety margin using the Eurocode 4. The slip capacity of cap-type shear connector was shown to exceed the limit value of 6mm for sufficiently ductile behavior.

고강도 전단보강 철근을 사용한 철근콘크리트 보의 거동평가 (Structural Behavior of Reinforced Concrete Beams using High Strength Shear Reinforcement)

  • 최임준;박종욱;황현복;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.3-4
    • /
    • 2009
  • 본 연구에서는 전단보강 철근 및 콘크리트 강도에 따른 철근콘크리트 보의 구조적 거동 파악과 현재 사용되고 있는 전단보강 철근의 강도 제한을 평가하였다. 현행 설계기준에서, 실제 설계되는 콘크리트구조물에 적용되는 전단보강 철근은 항복강도가 400 MPa 이하이어야 한다고 규정하고 있는데 이것은 항복강도가 너무 큰 철근을 사용하는 경우, 구조물에 과도한 균열이나 처짐이 발생할 수 있고, 연성능력, 피로 저항성능, 전단 및 비틀림 저항성능, 정착 성능, 내진 저항성능 등에 대하여 검증 되지 않았기 때문이다. 따라서 본 연구를 통해 고강도의 전단보강 철근이 콘크리트 구조물에 적용되었을 때 나타나는 철근콘크리트 보의 거동 및 구조적 성능을 평가하였다.

  • PDF