• 제목/요약/키워드: Shear building

검색결과 1,094건 처리시간 0.031초

스티프너로 보강한 콘크리트 충전 원형 강관기둥의 부착응력에 관한 실험적 연구 (An Experimental Study on a Bond Stress in Concrete Filled Circular Steel Tubular Column Strengthened by the Stiffener)

  • 박성무;김성수;김원호;이형석
    • 한국공간구조학회논문집
    • /
    • 제2권2호
    • /
    • pp.51-58
    • /
    • 2002
  • This paper is presented an experimental studies on bond stress between steel and concrete in concrete filled steel tubes. In the actual building frames, vertical dead and live loads on beams are usually transferred to columns by beam-to-column connections. In case when concrete filled steel tubes are used as columns of an actual building frame which has a simple connection, shear forces in the beam ends are not directly transferred to the concrete core but directly to the steel tube. Provided that the bond effect between steel tube and concrete core should not be expected, none of the end shear in the beams would be transferred to the concrete core but only to the steel tube. Therefore, it is important to investigate the bond strength between steel tube and concrete core in the absence of shear connectors.

  • PDF

중심 축 하중을 받는 충전각형강관 합성기둥의 부착응력에 관한연구 (Experimental Study on Bond Stress of Concrete Filled Rectangular Steel Tubular Composite Column Subjected to Axial Load)

  • 이형석;박성무
    • 한국공간구조학회논문집
    • /
    • 제3권3호
    • /
    • pp.105-110
    • /
    • 2003
  • This paper is presented an experimental studies on bond stress between steel and concrete in concrete filled Rectangular steel tubes. In the actual building frames, vertical dead and live loads on beams are usually transferred to columns by beam-to-column connections. In case when concrete filled steel tubes are used as columns of an actual building frame which has a simple connection, shear forces in the beam ends are not directly transferred to the concrete core but directly to the steel tube. Provided that the bond effect between steel tube and concrete core should not be expected, none of the end shear in the beams would be transferred to the concrete core but only to the steel tube. Therefore, it is important to investigate the bond strength between steel tube and concrete core in the absence of shear connectors.

  • PDF

벽식 건물의 탄성해석에서 벽체의 모델화 방법 검토 (On Modeling of Shear Wall Element in Eastic Analysis of Building Structures with Shear Walls)

  • 전대한
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.180-187
    • /
    • 1998
  • In this paper the attention is focused on the modeling of reinforced concrete(R/C) wall structures to check effectiveness and reliability of elasto-plastic analysis. A relatively simple and reliable wall model is investigated, which is suitable to be efficiently incorporated in a practical pushover analysis of R/C wall structural systems. Two types of analogous frames have been examined to the stress analysis of shear walls. One analogous frame is similar to the widely used wide-column model, the second analogous frame also is called truss model which includes vertical edge column and braces. Further studies are needed to apply to nonlinear seismic analysis of building structure with R/C shear walls.

  • PDF

원전구조물의 Gr.80 전단철근 사용을 위한 ASME-CC 코드개정에 관한 연구 (ASME-CC Code Change to use the Gr.80 Shear Reinforcement in Nuclear Power Plant Structure)

  • 이병수;임상준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.9-10
    • /
    • 2015
  • Generally significant reinforcement is used in nuclear power plant structures and may cause potential problems when concrete is poured. In particular pouring concrete into structural member joint area is more difficult than other areas since the joint area is very congested due to the crossed bars and the embedded plates, The purpose of this study is to solve these problems by applying Gr.80(550MPa) shear bars to containment structures of nuclear power plant. In order to apply them to containment structures, it is necessary to change ASME-CC code (ASME Sec.III Div.2). The structural performance tests of wall & beam have been done to compare Gr.80(550Mpa) with Gr.60(420MPa) shear bars. The test results and code change proposal were presented to ASME-CC Committee last year and the discussion for code change will be expected to proceed in the near future.

  • PDF

Perfobond 크기에 따른 콘크리트와 철재 합성재의 거동 실험 (Experiments on behavior of concrete and steel composite based on perfobond size)

  • 김동연;임홍철;박성운;김도균;류승일;박대원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.85-86
    • /
    • 2014
  • Connection between concrete and steel in composite members are usually achieved through shear connectors. In this study, the shear strength of concrete througth the holes of perfobond is experimentally obtained. Based on the size of perfobond, different strengths have been obtained and analyzed.

  • PDF

High-rise Reinforced-concrete Building Incorporating an Oil Damper in an Outrigger Frame and Its Vibration Analysis

  • Omika, Yukihiro;Koshika, Norihide;Yamamoto, Yukimasa;Kawano, Kenichi;Shimizu, Kan
    • 국제초고층학회논문집
    • /
    • 제5권1호
    • /
    • pp.43-50
    • /
    • 2016
  • The reinforced-concrete multi-story shear-wall structure, which can free a building from beams and columns to allow the planning of a vast room, has increasingly been used in Japan as a high-rise reinforced-concrete structure. Since this structural system concentrates the seismic force onto multi-story shear walls inside, the bending deformation of the walls may cause excessive deformation on the upper floors during an earthquake. However, it is possible to control the bending deformation to within a certain level by setting high-strength and rigid beams (outriggers) at the top of the multi-story shear walls; these outriggers restrain the bending behavior of the walls. Moreover, it is possible to achieve high energy dissipation by placing vibration control devices on the outriggers and thus restrain the bending behavior. This paper outlines the earthquake response analysis of a high-rise residential tower to demonstrate the effectiveness of the outrigger frame incorporating vibration control devices.

Estimation of the Fundamental Period for Residential Buildings with Shear-Wall System

  • Chun, Young-Soo;Chang, Kug-Kwan;Lee, Li-Hyung
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.121-130
    • /
    • 2000
  • This study focused on evaluating the reliability of code formulas such as those of the current Korean Building Code(KBC 1988). UBC 1997, NBCC 1995. and BSLJ 1994 for estimating the fundamental period of RC apartment buildings with shear-wall dominant systems, representative of typical residential buildings in Korea. For this purpose, full-scale measurements were carried out on fifty RC apartment buildings, and these results were compared to those obtained by code formulas and also by dynamic analysis. Although these code formulas are based on the measured periods of buildings during various earthquakes and building period varies with the amplitude of structural deflection or strain level, ambient surveys should provide an effective tool for experimentally verifying the design period to the completed building. This comparison shows that comparatively large errors are likely to occure when the code formula of KBC 1988 is used, and all the other code formulas are not sufficient to estimate the fundamental period of apartment buildings with shear-wall dominant systems. An improved formula is proposed by regression analysis on the basis of the measured period data. The proposal is for the servicebility stress level, but it can also be applied for seismic code in the regions of low seismicity similar to Korea.

  • PDF

콜드조인트 지연시간에 따른 초고성능 콘크리트의 부착성능평가에 관한 실험적 연구 (An Experimental Study on Bonding Performance Evaluation of UHPC in Accordance with Delay Time of Cold Joints)

  • 장현오;김보석;장종민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.22-23
    • /
    • 2016
  • This study aims to derive the optimal condition that ensures the monolithicity of ultra-high performance concrete (UHPC), through the evaluation of bonding shear performance with respect to the time of cold joint occurrence during the placement. From the direct shear test, while the normalized bonding shear strength reduction of UHPC with the delay time of 15 minutes was the lowest at around 8%, a dramatic degradation of bonding shear performance was observed after 15 minutes. XRD analysis of the middle and surface sections was performed in order to analyze the composition of the thin film formed at the surface of UHPC, and as a result, the main ingredient appeared to be SiO2 from the XRD pattern of middle and surface sections, which is believed to be the result of the rising of SiO2-based filler, used as anadmixture in this study, toward the surface, due to its low specific gravity.

  • PDF

구조적 손상을 입은 철근콘크리트 보의 전단보강 효과에 관한 연구 (A Study on the Shear Strengthening Effect of Reinforced Concrete Beams with Structural Damage)

  • 신용석;김정훈;김정섭;김광석;조철희
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.43-51
    • /
    • 2008
  • This study examines shear capacity performance and structural characteristics of reinforced concrete beam using carbon fiber sheet(CFS), g)ass fiber sheet(GFS), glass fiber steel plate(GSP) and carbon fiber bar CB) which are reinforcing materials for reinforced concrete beam in order to produce similar condition to repair and reinforce actual structure and aims to provide data available In designing and constructing reinforced concrete structures under the structural damage. This study obtains the following conclusions. After considering the shear experiment results. it was indicated that the CB reinforced test object was the best in the shear capacity improvement and ductility capacity as it was contained in the concrete and was all operated, Also, GFS reinforced test object indicated the reduced flexural capacity but good shear capacity. GSP reinforced test object had bigger reinforcing strength than other reinforcing test objects. On the other hand, it showed the lowest reinforcement effect as compared section thickness of reinforced material because it showed the bigger relativity a section thickness of reinforced material. If the adherence to the concrete is improved, it will seem to show bigger reinforcement effect.

개구부가 있는 고층 벽식 구조물의 효율적인 3차원 해석 (Efficient Three Dimensional Analysis of High-Rise Shear Wall Building with Openings)

  • 김현수;남궁계홍;이동근
    • 한국전산구조공학회논문집
    • /
    • 제15권2호
    • /
    • pp.351-365
    • /
    • 2002
  • 현재 국내에서는 벽체와 바닥판으로만 구성된 벽식 구조형식의 아파트 건물이 많이 사용되고 있다. 또한 청력에 대한 저항이 뛰어나기 때문에 전단벽 코어를 갖는 입체골조구조물이 고층 빌딩의 구조시스템으로 자주 이용된다. 기능적인 이유로 인해 이러한 구조물들의 전단벽에는 하나 또는 여러 개의 개구부가 발생하게 된다. 개구부가 있는 전단벽을 정확하게 해석하기 위해서는 여러 개의 유한요소를 사용하여 구조물을 세분모형화하는 것이 필요하다. 그러나, 전체 구조물을 유한요소로 세분하여 모형화하는 것은 막대한 해석시간과 컴퓨터 메모리를 소요하게 된다. 개구부의 수, 크기, 위치에 상관없이 적용할 수 있는 효율적인 해석기법이 본 논문에서 제안되었다. 제안된 해석기법에서는 슈퍼요소와 부분구조, 행렬응축, 가상보 등을 이용하였고 제안된 해석기법의 효율성을 검증하기 위해 벽식구조물과 전단벽 코어를 갖는 입체골조구조물의 3차원 해석이 수행되었다. 예제구조물의 해석을 통해 제안된 해석기법이 해석시간과 컴퓨터메모리를 크게 감소시키고, 정확한 해석결과를 얻을 수 있음이 확인되었다.