• 제목/요약/키워드: Shear bond strength (SBS)

검색결과 81건 처리시간 0.022초

Shear bond strength of luting cements to fixed superstructure metal surfaces under various seating forces

  • Ozer, Fusun;Pak-Tunc, Elif;Dagli, Nesrin Esen;Ramachandran, Deepika;Sen, Deniz;Blatz, Markus Bernhard
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.340-346
    • /
    • 2018
  • PURPOSE. In this study, the shear bond strengths (SBS) of luting cements to fixed superstructure metal surfaces under various seating forces were investigated. MATERIALS AND METHODS. Seven different cements [Polycarboxylate (PCC), Glass-Ionomer (GIC), Zinc phospahate (ZPC), Self-adhesive resin (RXU), Resin (C&B), and Temporary cements ((RXT) and (TCS))] were bonded to a total number of 224 square blocks ($5{\times}5{\times}3mm$) made of one pure metal [Titanium (CP Ti) and two metal alloys [Gold-Platinum (Au-Pt) and Cobalt-Chrome (Co-Cr)] under 10 N and 50 N seating forces. SBS values were determined and data were analyzed with 3-way ANOVA. Pairwise comparisons and interactions among groups were analyzed with Tukey's simultaneous confidence intervals. RESULTS. Overall mean scores indicated that Co-Cr showed the highest SBS values ($1.96{\pm}0.4$) (P<.00), while Au-Pt showed the lowest among all metals tested ($1.57{\pm}0.4$) (P<.00). Except for PCC/CP Ti, RXU/CP Ti, and GIC/Au-Pt factor level combinations (P<.00), the cements tested under 10 N seating force showed no significantly higher SBS values when compared to the values of those tested under 50 N seating force (P>.05). The PCC cement showed the highest mean SBS score ($3.59{\pm}0.07$) among all cements tested (P<.00), while the resin-based temporary luting cement RXT showed the lowest ($0.39{\pm}0.07$) (P<.00). CONCLUSION. Polycarboxylate cement provides reliable bonding performance to metal surfaces. Resin-based temporary luting cements can be used when retrievability is needed. GIC is not suitable for permanent cementation of fixed dental prostheses consisting of CP Ti or Au-Pt substructures.

Influence of nonthermal argon plasma on the shear bond strength between zirconia and different adhesives and luting composites after artificial aging

  • Pott, Philipp-Cornelius;Syvari, Timo-Sebastian;Stiesch, Meike;Eisenburger, Michael
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.308-314
    • /
    • 2018
  • PURPOSE. Plasma activation of hydrophobic zirconia surfaces might be suitable to improve the bond strength of luting materials. The aim of this study was to analyze the influence of nonthermal argon-plasma on the shear bond strength (SBS) between zirconia and different combinations of 10-MDP adhesive systems and luting composites after artificial aging. MATERIALS AND METHODS. Two hundred forty Y-TZP specimens were ground automatically with $165{\mu}m$ grit and water cooling. Half of the specimens received surface activation with nonthermal argon-plasma. The specimens were evenly distributed into three groups according to the adhesive systems ([Futurabond U, Futurabond M, Futurabond M + DCA], VOCO GmbH, Germany, Cuxhaven) and into further two subgroups according to the luting materials ([Bifix SE, Bifix QM], VOCO GmbH). Each specimen underwent artificial aging by thermocycling and water storage. SBS was measured in a universal testing machine. Statistical analysis was performed using ANOVA and $Scheff{\grave{e}}$ procedure with the level of significance set to 0.05. RESULTS. Surface activation with nonthermal plasma did not improve the bond strength between zirconia and the tested combinations of adhesive systems and luting materials. The plasma-activation trended to reveal higher bond strength if the self-etch luting material (Bifix SE) was used, irrespective of the adhesive system. CONCLUSION. Plasma-activation seems to be suitable to improve bond strength between zirconia and self-etch resin materials. However, further research is necessary to identify the influence of varying plasma-parameters.

Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons

  • Gungor, Ahmet Yalcin;Alkis, Huseyin;Turkkahraman, Hakan
    • 대한치과교정학회지
    • /
    • 제43권2호
    • /
    • pp.96-100
    • /
    • 2013
  • Objective: To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods: We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results: ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III ($10.73{\pm}0.96$ MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth ($4.17{\pm}1.11$ MPa) (p < 0.001). Conclusions: Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth.

The effect of silane and universal adhesives on the micro-shear bond strength of current resin-matrix ceramics

  • Sarahneh, Omar;Gunal-Abduljalil, Burcu
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권5호
    • /
    • pp.292-303
    • /
    • 2021
  • PURPOSE. The aim of this in vitro study was to evaluate the effect of silane and universal adhesive applications on the micro-shear bond strength (µSBS) of different resin-matrix ceramics (RMCs). MATERIALS AND METHODS. A total of 120 slides (14 × 12 × 1 mm) were produced from 5 different RMC materials (GC Cerasmart [GC]; Brilliant Crios [BC]; Grandio blocs [GB]; Katana Avencia [KA]; and KZR-CAD HR 2 [KZR]) and sandblasted using 50 ㎛ Al2O3 particles. Each RMC material was divided into six groups according to the surface conditioning (SC) method as follows: control (G1), silane primer (G2), silane-free universal adhesive (G3), silane-containing universal adhesive (G4), silane primer and silane-free universal adhesive (G5), and silane primer and silane-containing universal adhesive (G6). Three cylindric specimens made from resin cement (Bifix QM) were polymerized over the treated surface of each slide (n = 12). After thermal cycling (10000 cycles, 5 - 55℃), µSBS test was performed and failure types were evaluated using a stereomicroscope. Data were analyzed using 2-way ANOVA and Tukey tests (α = .05). RESULTS. µSBS values of specimens were significantly affected by the RMC type and SC protocols (P < .001) except the interaction (P = .119). Except for G2, all SC protocols showed a significant increase in µSBS values (P < .05). For all RMCs, the highest µSBS values were obtained in G4 and G6 groups. CONCLUSION. Only silane application did not affect the µSBS values regardless of the RMC type. Moreover, the application of a separate silane in addition to the universal adhesives did not improve the µSBS values. Silane-containing universal adhesive was found to be the best conditioning method for RMCs.

Comparative evaluation of the bond strength of self-adhering and bulk-fill flowable composites to MTA Plus, Dycal, Biodentine, and TheraCal: an in vitro study

  • Raina, Aakrati;Sawhny, Asheesh;Paul, Saurav;Nandamuri, Sridevi
    • Restorative Dentistry and Endodontics
    • /
    • 제45권1호
    • /
    • pp.10.1-10.8
    • /
    • 2020
  • Objectives: This study aimed to compare the shear bond strength (SBS) of a self-adhering flowable composite (Dyad Flow) and a bulk-fill flowable composite (Smart Dentin Replacement [SDR]) to several pulp-capping materials, including MTA Plus, Dycal, Biodentine, and TheraCal. Materials and Methods: Eighty acrylic blocks with 2-mm-deep central holes that were 4 mm in diameter were prepared and divided into 2 groups (n = 40 each) according to the composite used (Dyad Flow or SDR). They were further divided into 4 sub-groups (n = 10 each) according to the pulp-capping agent used. SBS was tested using a universal testing machine at a crosshead speed of 1 mm/min. Data were analyzed using 2-way analysis of variance. A p value of < 0.05 was considered to indicate statistical significance. Results: A statistically significant difference (p = 0.040) was found between Dyad Flow and SDR in terms of bond strength to MTA Plus, Dycal, Biodentine, and TheraCal. Conclusions: Among the 8 sub-groups, the combination of TheraCal and SDR exhibited the highest SBS.

Effect of storage time on chemical structure of a single-bottle and a two-bottle experimental ceramic primer and micro-shear bond strength of composite to ceramic

  • Armaghan Naghili;Amirparsa Ghasemi;Amir Ghasemi;Narges Panahandeh
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권3호
    • /
    • pp.163-173
    • /
    • 2024
  • PURPOSE. This study assessed the effect of storage time on chemical structure of a single-bottle and a two-bottle experimental ceramic primer and micro-shear bond strength (µSBS) of composite to ceramic. MATERIALS AND METHODS. This study was conducted on 60 sintered zirconia and 60 feldspathic porcelain blocks. Half of the specimens (n = 30) were subjected to surface treatment with the single-bottle Clearfil ceramic primer (n = 15) and two-bottle experimental primer (n = 15) after 24 hours. The remaining half received the same surface treatments after 6 months storage in distilled water. Composite cylinders were bonded to the ceramics, and they were then subjected to µSBS test. Also, the primers underwent Fourier-transform infrared spectroscopy (FTIR) after 24 hours and 6 months to assess their chemical structure. Data were analyzed with 3-way ANOVA and adjusted Bonferroni test (alpha = 0.05). RESULTS. The µSBS of both ceramics significantly decreased at 6 months in one-bottle ceramic primer group (P = .001), but it was not significantly different from the two-bottle experimental primer group (P = .635). FTIR showed hydrolysis of single-bottle primer, cleavage of silane and 10-MDP bonds, and formation of siloxane bonds after 6 months. CONCLUSION. Six months of storage caused significant degradation of single-bottle ceramic primer, and consequently had an adverse effect on µSBS.

Shear bond strengths of aged and non-aged CAD/CAM materials after different surface treatments

  • Kilinc, Hamiyet;Sanal, Fatma Ayse;Turgut, Sedanur
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.273-282
    • /
    • 2020
  • PURPOSE. To assess shear bond strengths (SBS) of resin composites on aged and non-aged prosthetic materials with various surface treatments. MATERIALS AND METHODS. Cerasmart (CE), Vita Enamic (VE), Vita Mark II (VM), and IPS e.max CAD (EC) blocks were sliced, and rectangular-shaped specimens (14 × 12 × 1.5 mm; N = 352) were obtained. Half of the specimens were aged (5000 thermal cycles) for each material. Non-aged and aged specimens were divided into 4 groups according to the surface treatments (control, air abrasion, etching, and laser irradiation; n = 11) and processed for scanning electron microscopy (SEM). The repair procedure was performed after the surface treatments. SBS values and failure types were determined. Obtained data were statistically analyzed (P≤.05). RESULTS. The material type, surface treatment type, and their interactions were found significant with regard to SBS (P<.001). Aging also had a significant effect on prosthetic material-resin composite bonding (P<.001). SBS values of non-aged specimens ranged from 12.16 to 17.91 MPa, while SBS values of aged specimens ranged from 9.46 to 15.61 MPa. Non-aged VM in combination with acid etching presented the highest score while the control group of aged CE showed the lowest. CONCLUSION. Etching was more effective in achieving durable SBS for VM and EC. Laser irradiation could be considered as an alternative surface treatment method to air abrasion for all tested materials. Aging had significant effect on SBS values generated between tested materials and resin composite.

Effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin

  • Singh, Payal;Nagpal, Rajni;Singh, Udai Pratap
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.188-199
    • /
    • 2017
  • Objectives: This in vitro study evaluated the effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin. Materials and Methods: Flat coronal dentin surfaces were prepared in 120 extracted human molars. Teeth were randomly divided into 5 groups (n = 24) according to 5 different surface pre-treatments: No pre-treatment (control); 1M carbodiimide (EDC); 0.1% epigallocatechin-3-gallate (EGCG); 2% minocycline (MI); 10% sodium ascorbate (SA). After surface pre-treatment, adhesive (Adper Single Bond 2 [SB], 3M ESPE) was applied. Composite was applied into transparent plastic tubes (2.5 mm in diameter), which was placed over the bonded dentin surface. From each group, 10 samples were subjected to shear bond strength (SBS) evaluation at 24 hours (immediate) and remaining 10 samples were tested after 6 months (delayed). Additionally, 4 samples per group were subjected to scanning electron microscopic analysis for observation of resin-dentin interface. The data were statistically analysed with Shaperio-Wilk W test, 2-way analysis of variance (ANOVA), and post hoc Tukey's test. Results: At 24 hours, SBS of all surface pre-treatment groups were comparable with the control group, with significant differences found between EDC and SA groups only (p = 0.009). After 6 months storage, EDC, EGCG, and MI pre-treatments preserved the resindentin bond strength with no significant fall. Conclusions: Dentin pre-treatment with all the dentin biomodifiers except SA resulted in significant preservation of resin-dentin bond over 6 months storage period, without negatively affecting the immediate bond strength of the etch and rinse adhesive tested.

Tricalcium Silicate-Based 치수복조재에 대한 수 종 수복재의 전단결합강도 비교 (Comparison of Shear Bond Strength of Different Restorative Materials to Tricalcium Silicate-Based Pulp Capping Materials)

  • 정화경;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제44권2호
    • /
    • pp.200-209
    • /
    • 2017
  • 본 연구의 목적은 Tricalcium silicate를 기반으로 한 3종의 치수복조재(Theracal $LC^{TM}$, $Biodentine^{TM}$, $ProRoot^{TM}$ white MTA)와 임상에서 통상적으로 사용되는 수복재인 복합레진, 레진강화형 글래스아이오노머 시멘트, 그리고 전통적인 글래스아이오노머 시멘트 간의 전단결합강도를 비교 평가하는 것이다. 이를 위해 중심구를 가진 아크릴 레진 블록 90개를 제작하고 각각 30개씩 3종의 치수복조재로 중심구 안에 채운 다음, 다시 무작위로 10개씩 하위 군을 나누어 치수복조재 상방에 복합레진, 레진강화형 글래스아이오노머 시멘트, 전통적인 글래스아이오노머 시멘트를 적용하여 총 9개 군으로 이루어진 시편을 제작하였다. Universal testing machine을 이용해 전단결합강도를 측정한 뒤, 입체현미경을 사용해 파절양상을 분석하였다. 연구 결과, Theracal $LC^{TM}$-복합레진 군이 가장 높은 전단결합강도를, Theracal $LC^{TM}$-전통적인 글래스아이오노머 시멘트 군이 가장 낮은 전단결합강도를 나타냈다. 복합레진이 수복재로 선택된 군들이 다른 수복재 군에 비해 높은 전단결합강도를 보였다. 전통적인 글래스아이오노머 시멘트가 수복재인 경우 $Biodentine^{TM}$이 다른 치수복 조재 군들에 비해 높은 전단결합강도를 나타냈다.

단결정형 세라믹 브라켓의 재접착 시 tribochemical silica coating이 전단접착강도에 미치는 영향 (Effect of tribochemical silica coating on the shear bond strength of rebonded monocrystalline ceramic brackets)

  • 전영미;손우성;강상욱
    • 대한치과교정학회지
    • /
    • 제40권3호
    • /
    • pp.184-194
    • /
    • 2010
  • 본 연구는 탈락된 세라믹 브라켓을 tribochemical silica coating하고 nano-filled flowable composite resin (Transbond Supreme LV, 3M Unitek, Monrovia, Calif, USA)을 이용하여 재접착하였을 때 교정치료에 충분한 접착강도를 얻을 수 있는지 평가하기 위해 시행하였다. 총 60개의 소구치를 준비하여 다음의 4개 군으로 나누었다: Tribochemical silica coating (TC) + Transbond Supreme LV (LV), TC + Transbond XT (XT), Sandblast treatment(SA) + LV, SA + XT. 재처리된 세라믹 브라켓은 각각의 접착제를 이용하여 치아에 부착하였다. 시편들을 상온의 생리식염수에 1주일간 보관한 뒤 열순환을 시켰다. 만능시험기로 전단접착강도를 측정한 뒤 파절양상을 평가하였다. TC군은 임상적으로 충분한 강도를 보였다(TCLV: 10.82 $\pm$ 1.82 MPa, TCXT: 11.50 $\pm$ 1.72 MPa). 하지만 SA군은TC군에 비하여 유의하게 낮은 전단접착강도를 보였다(SALV: 1.23 $\pm$ 1.16 MPa, SAXT: 1.76 $\pm$ 1.39 MPa, p < 0.05). LV군과 XT군의 전단접착강도는 유의한 차이가 없었다. TCLV, TCXT군 모두 시편의 77%가 접착제에서의 파절을 보였고, 각 군당 1개씩의 시편에서 법랑질 파절이 관찰되었다. SA군은 모든 파절이 브라켓과 접착제 계면에서 발생하였다. LV군과 XT군의 탈락양상에는 유의한 차이가 없었다. 이상의 연구 결과에서 보면 nano-filled flowable composite resin과 tribochemical silica coating 처리를 이용하여 세라믹 브라켓을 재접착하면 충분한 전단접착강도를 얻을 수 있다. 단 법랑질 파절의 가능성이 있으므로 탈접착 시 적절한 기구와 기술을 이용해 주의깊게 브라켓을 제거해야 한다.