• 제목/요약/키워드: Shear bond strength (SBS)

검색결과 82건 처리시간 0.022초

Shear bond strength of zirconia to resin: The effects of specimen preparation and loading procedure

  • Chen, Bingzhuo;Yang, Lu;Lu, Zhicen;Meng, Hongliang;Wu, Xinyi;Chen, Chen;Xie, Haifeng
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.313-323
    • /
    • 2019
  • PURPOSE. Shear bond strength (SBS) test is the most commonly used method for evaluating resin bond strength of zirconia, but SBS results vary among different studies even when evaluating the same bonding strategy. The purpose of this study was to promote standardization of the SBS test in evaluating zirconia ceramic bonding and to investigate factors that may affect the SBS value of a zirconia/resin cement/composite resin bonding specimen. MATERIALS AND METHODS. The zirconia/resin cement/composite resin bonding specimens were used to simulate loading with a shear force by the three-dimensional finite element (3D FE) modeling, in which stress distribution under uniform/non-uniform load, and different resin cement thickness and different elastic modulus of resin composite were analyzed. In vitro SBS test was also performed to validate the results of 3D FE analysis. RESULTS. The loading flat width was an important affecting factor. 3D FE analysis also showed that differences in resin cement layer thickness and resin composite would lead to the variations of stress accumulation area. The SBS test result showed that the load for preparing a SBS specimen is negatively correlated with the resin cement thickness and positively correlated with SBS values. CONCLUSION. When preparing a SBS specimen for evaluating bond performance, the load flat width, the load applied during cementation, and the different composite resins used affect the SBS results and therefore should be standardized.

Effect of various bleaching treatments on shear bond strength of different universal adhesives and application modes

  • Oz, Fatma Dilsad;Kutuk, Zeynep Bilge
    • Restorative Dentistry and Endodontics
    • /
    • 제43권2호
    • /
    • pp.20.1-20.9
    • /
    • 2018
  • Objectives: The aim of this in vitro study was to evaluate the bond strength of 2 universal adhesives used in different application modes to bleached enamel. Materials and Methods: Extracted 160 sound human incisors were used for the study. Teeth were divided into 4 treatment groups: No treatment, 35% hydrogen peroxide, 16% carbamid peroxide, 7.5% carbamid peroxide. After bleaching treatments, groups were divided into subgroups according to the adhesive systems used and application modes (n = 10): 1) Single Bond Universal, etch and rinse mode; 2) Single Bond Universal, self-etch mode; 3) Gluma Universal, etch and rinse mode; 4) Gluma Universal, self-etch mode. After adhesive procedures nanohybrid composite resin cylinders were bonded to the enamel surfaces. All specimens were subjected to shear bond strength (SBS) test after thermocycling. Data were analyzed using a 3-way analysis of variance (ANOVA) and Tukey post hoc test. Results: No significant difference were found among bleaching groups (35% hydrogen peroxide, 16% carbamid peroxide, 7.5% carbamid peroxide, and no treatment groups) in the mean SBS values. There was also no difference in SBS values between Single Bond Universal and Gluma Universal at same application modes, whereas self-etch mode showed significantly lower SBS values than etch and rinse mode (p < 0.05). Conclusions: The bonding performance of the universal adhesives was enhanced with the etch and rinse mode application to bleached enamel and non-bleached enamel.

Effect of adhesive application method on repair bond strength of composite

  • Hee Kyeong Oh;Dong Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.32.1-32.10
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effect of the application method of universal adhesives on the shear bond strength (SBS) of repaired composites, applied with different thicknesses. Materials and Methods: The 84 specimens (Filtek Z350 XT) were prepared, stored in distilled water for a week and thermocycled (5,000 cycles, 5℃ to 55℃). They were roughened using 400-grit sandpapers and etched with phosphoric acid. Then, specimens were equally divided into 2 groups; Single Bond Universal (SU) and Prime&Bond Universal (PB). Each group was subdivided into 3 subgroups according to application methods (n = 14); UC: 1 coat + uncuring, 1C: 1 coat + curing, 3C: 3 coats + curing. After storage of the repaired composite for 24 hours, specimens were subjected to the SBS test and the data were statistically analyzed by 2-way analysis of variance and independent t-tests. Specimens were examined with a stereomicroscope to analyze fracture mode and a scanning electron microscope to observe the interface. Results: Adhesive material was a significant factor (p = 0.001). Bond strengths with SU were higher than PB. The highest strength was obtained from the 1C group with SU. Bonding in multiple layers increased adhesive thicknesses, but there was no significant difference in SBS values (p = 0.255). Failure mode was predominantly cohesive in old composites. Conclusions: The application of an adequate bonding system plays an important role in repairing composite resin. SU showed higher SBS than PB and the additional layers increased the adhesive thickness without affecting SBS.

Effect of surface treatment and luting agent type on shear bond strength of titanium to ceramic materials

  • Karaokutan, Isil;Ozel, Gulsum Sayin
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.78-87
    • /
    • 2022
  • PURPOSE. This study aimed to compare the effect of different surface treatments and luting agent types on the shear bond strength of two ceramics to commercially pure titanium (Cp Ti). MATERIALS AND METHODS. A total of 160 Cp Ti specimens were divided into 4 subgroups (n = 40) according to surface treatments received (control, 50 ㎛ airborne-particle abrasion, 110 ㎛ airborne-particle abrasion, and tribochemical coating). The cementation surfaces of titanium and all-ceramic specimens were treated with a universal primer. Two cubic all-ceramic discs (lithium disilicate ceramic (LDC) and zirconia-reinforced lithium silicate ceramic (ZLC)) were cemented to titanium using two types of resin-based luting agents: self-cure and dual-cure (n = 10). After cementation, all specimens were subjected to 5000 cycles of thermal aging. A shear bond strength (SBS) test was conducted, and the failure mode was determined using a scanning electron microscope. Data were analyzed using three-way ANOVA, and the Tukey-HSD test was used for post hoc comparisons (P < .05). RESULTS. Significant differences were found among the groups based on surface treatment, resin-based luting agent, and ceramic type (P < .05). Among the surface treatments, 50 ㎛ air-abrasion showed the highest SBS, while the control group showed the lowest. SBS was higher for dual-cure resin-based luting agent than self-cure luting agent. ZLC showed better SBS values than LDC. CONCLUSION. The cementation of ZLC with dual-cure resin-based luting agent showed better bonding effectiveness to commercially pure titanium treated with 50 ㎛ airborne-particle abrasion.

Effect of an aluminum chloride hemostatic agent on the dentin shear bond strength of a universal adhesive

  • Sujin Kim;Yoorina Choi;Sujung Park
    • Restorative Dentistry and Endodontics
    • /
    • 제48권2호
    • /
    • pp.14.1-14.11
    • /
    • 2023
  • Objectives: This study investigated the effect of an aluminum chloride hemostatic agent on the shear bond strength (SBS) of a universal adhesive to dentin. Materials and Methods: Eighty extracted human molars were trimmed at the occlusal dentin surfaces and divided mesiodistally. According to hemostatic agent application, specimens were randomly allocated into control (C) and hemostatic agent (Traxodent; H) groups. Each group was divided into 4 subgroups according to the adhesive system (n = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond Universal etch-and-rinse mode (ALER), and All-Bond Universal self-etch mode (ALSE). SBS was measured for half of the specimens at 24 hours, and the other half were thermocycled in water baths (group T). Fracture surfaces were examined to determine the failure mode. The SBS was measured, and data were analyzed using 1-way analysis of variance, the Student's t-test, and the Tukey honestly significant difference test (p = 0.05). Results: No significant differences in SBS were found between groups C and H for any adhesive system at 24 hours. After thermocycling, a statistically significant difference was observed between CT+ALSE and HT+ALSE (p < 0.05). When All-Bond Universal was applied to hemostatic agent-contaminated dentin, the SBS of H+ALSE was significantly lower than that of H+ALER (p < 0.05). The SBER subgroups showed no significant differences in SBS regardless of treatment and thermocycling. Conclusions: When exposed dentin was contaminated by an aluminum chloride hemostatic agent before dentin adhesive treatment, application of All-Bond Universal in etch-and-rinse mode was superior to self-etch mode.

교정용 브라켓에 가해지는 힘의 방향에 따른 결합강도의 비교 (Comparison of bracket bond strength in various directions of force)

  • 이현정;이형순;전영미;김정기
    • 대한치과교정학회지
    • /
    • 제33권5호
    • /
    • pp.359-370
    • /
    • 2003
  • 본 연구는 교정용 금속 브라켓에 다양한 방향에서의 복합적인 응력을 가하여 힘의 방향과 적용점에 따른 교정용 브라켓의 결합강도를 비교하고, 브라켓의 유지력을 평가하는데 기준이 되는 최소결합강도의 특성에 대해 알아보고자 시행되었다. 일정 한 표면특성을 갖는 금속봉에 Micro-Loc base, Chessboard base, Non-etched Foil-Mesh base 등 서로 다른 기저 면 형태를 가지는 3가지 종류의 금속 브라켓을 부착시키고, $0^{\circ},\;15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ},\;75^{\circ},\;90^{\circ}$의 Peel 결합강도$(_0PBS, \;_{15}PBS,\;_{30}PBS,\;_{45}PBS,\;_{60}PBS,\;_{75}PBS,\;_{90}PBS)$ 및 전단결합강도(SBS)와 인장결합강도(TBS)에 대한 브라켓의 결합강도를 측정하고, 각 브라켓의 기저면 면적을 고려하여 단위면적당 결합강도를 산출하여 비교한 결과 다음과 같은 결론을 얻었다. 1. Micro-Loc base와 Chessboard base 및 Non-etched Foil-Mesh base 브라켓 모두에서 전단결합강도(SBS)가 가장 컸다(P<0.01). 2. Peel 응력의 방향 변화에 따른 peel 결합강도(PBS)의 변화양상은 Micro-Loc base와 Chessboard base, Non-etched Foil-Mesh base 브라켓 모두에서 유사하였으며 (p>0.05), peel 응력의 적용 각이 증가할수록 peel 결합강도(PBS)는 감소하였고 $60^{\circ}$에서 최저값을 보였다(p<0.05). 3. Micro-Loc base에서 최저 peel 결합강도$(_{60}PBS)$는 전단결합강도(SBS)의 $29\%$ 수준이었으며, 인장결합강토(TBS)에 대해서는 $52\%$ 수준이었고, Chessboard base에서 최저 Peel bond strength$(_{60}PBS)$는 전단결합강도(SBS)의 $34\%$ 수준이었으며, 인장결합강도(TBS)에 대해서는 $61\%$ 수준이었으며, Non-etched Foil-Mesh base에서 최저 Peel 결합 강도$(_{60}PBS)$는 전단결합강도(SBS)의 $34\%$ 수준이었으며, 인장결합강도(TBS)에 대해서는 $55\%$ 수준이었다. 4. 단위 면적 당 결합강도에 있어서 전단결합강도(SBS)와 인장결합강도(TBS) 및 $75^{\circ}\;와\;90^{\circ}$ peel 결합강도는 Micro-Loc base와 Chessboard base에서 차이 가 없었으며 Non-etched Foil-Mesh base에서 가장 작았고(p<0.05), $0^{\circ},\;15^{\circ},\;30^{\circ},\;60^{\circ}$ peel응력을 적용한 결과 Chessboard base에서 가장 큰 Peel결합강도를, Non-etched Foil-Mesh base에서 가장 작은 결합강도를 보였다(p<0.05).

브라켓 기저부 형태에 따른 전단, 인장, 전단/인장복합결합강도의 비교 (Comparison of shear, tensile and shear/tensile combined bonding strengths in bracket base configurations)

  • 이춘봉;이승호;김정기
    • 대한치과교정학회지
    • /
    • 제29권5호
    • /
    • pp.599-611
    • /
    • 1999
  • 금속 브라켓의 결합강도에 영향을 미치는 요소인 브라켓 기저부의 형태와 결합 부위에 적용되는 힘의 특성에 대해 알아보고자 연구를 시행하였다. 형태가 다른 5종의 금속브라켓의 기저부와 결합강도 측정후 접착파절양상을 stereoscope and scanning electron microscope를 통해 관찰하고 결합 부위에 적용되는 힘은 전단결합강도, 인장결합강도, 전단/인장복합결합강도로 구분하고 결합강도를 비교하여 다음과 같은 결론을 얻었다. 1. 브라켓 기저부 형태에 따른 모든 군에서 전단결합강토(SBS)가 제일 컸으며, 인장결합강도(TBS)는 SBS의 50%정도 수준이었고 전단/인장복합결합강도(S/TBS)는 전단결합강도(SBS)의 30%정도이었다. 2. 브라켓의 결합강도는 Micro-Loc base가 가장 크고($SBS:22.86{\pm}1.37kgf,\;TBS:11.37{\pm}1.43kgf,\;S/TBS:6.69{\pm}0.34kgf$), Integral base가 가장 작았다($SBS:10.52{\pm}1.27kgf,\;TBS:4.27{\pm}1.08kgf,\;S/TBS:2.94{\pm}0.58kgf). 3. 단위면적당 결합강도 비교시, Integral base가 가장 작았고(p<0.05), 전단결합강도와 인장결합강도에서는 Micro-Loc과 Chessboard base간의 차이가 없었으며 (p>0.05), Non-Etched Foil Mesh와 Micro-Etched Foil Mesh base간의 전단결합강도와 인장결합강도는 차이가 없었으나, 전단/인장복합결합강도에서는 Micro-Etched Foil Mesh base가 Non-Etched Foil Mesh base보다 더 크게 나타났다. 4. 전단, 인장, 전단/인장복합결합강도 측정후 접착파절은 브라켓/레진 계면에서 일어나 ARI score가 작게 나타났다.

  • PDF

Effect of surface treatments on shear bond strength of resin composite bonded to CAD/CAM resin-ceramic hybrid materials

  • Gungor, Merve Bankoglu;Nemli, Secil Karakoca;Bal, Bilge Turhan;Unver, Senem;Dogan, Aylin
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.259-266
    • /
    • 2016
  • PURPOSE. The purpose of this study was to assess the effect of surface treatments on shear bond strength of resin composite bonded to thermocycled and non-thermocycled CAD/CAM resin-ceramic hybrid materials. MATERIALS AND METHODS. 120 specimens ($10{\times}10{\times}2mm$) from each material were divided into 12 groups according to different surface treatments in combination with thermal aging procedures. Surface treatment methods were airborne-particle abrasion (abraded with 50 micron alumina particles), dry grinding (grinded with $125{\mu}m$ grain size bur), and hydrofluoric acid (9%) and silane application. According to the thermocycling procedure, the groups were assigned as non-thermocycled, thermocycled after packing composites, and thermocycled before packing composites. The average surface roughness of the non-thermocycled specimens were measured after surface treatments. After packing composites and thermocycling procedures, shear bond strength (SBS) of the specimens were tested. The results of surface roughness were statistically analyzed by 2-way Analysis of Variance (ANOVA), and SBS results were statistically analyzed by 3-way ANOVA. RESULTS. Surface roughness of GC were significantly lower than that of LU and VE (P<.05). The highest surface roughness was observed for dry grinding group, followed by airborne particle abraded group (P<.05). Comparing the materials within the same surface treatment method revealed that untreated surfaces generally showed lower SBS values. The values of untreated LU specimens showed significantly different SBS values compared to those of other surface treatment groups (P<.05). CONCLUSION. SBS was affected by surface treatments. Thermocycling did not have any effect on the SBS of the materials except acid and silane applied GC specimens, which were subjected to thermocycling before packing of the composite resin.

Effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength and bond failure mode of metallic orthodontic brackets

  • Bonetti, Giulio Alessandri;Parenti, Serena Incerti;Ippolito, Daniela Rita;Gatto, Maria Rosaria;Checchi, Luigi
    • 대한치과교정학회지
    • /
    • 제44권1호
    • /
    • pp.44-49
    • /
    • 2014
  • Objective: To evaluate the effects of ultrasonic instrumentation with different scaler-tip angulations on the shear bond strength (SBS) and bond failure mode of metallic orthodontic brackets. Methods: Adhesive pre-coated metallic brackets were bonded to 72 extracted human premolars embedded in autopolymerizing acrylic resin. The teeth were randomly divided into 3 groups (n = 24 each) to undergo no treatment (control group) or ultrasonic instrumentation with a scaler-tip angulation of $45^{\circ}$ ($45^{\circ}$-angulation group) or $0^{\circ}$ ($0^{\circ}$-angulation group). SBS was tested in a universal testing machine, and adhesive remnant index (ARI) scores were recorded. The Kruskal-Wallis test and Mann-Whitney U-test were used for statistical analysis. Results: The control group had a significantly higher mean SBS value than the treated groups, which showed no significant differences in their mean SBS values. The ARI scores were not significantly different among the groups. Conclusions: Ultrasonic instrumentation around the bracket base reduces the SBS of metallic orthodontic brackets, emphasizing the need for caution during professional oral hygiene procedures in orthodontic patients. The scaler-tip angulation does not influence the SBS reduction and bond failure mode of such brackets.

Effect of non-thermal plasma on the shear bond strength of resin cements to Polyetherketoneketone (PEKK)

  • Labriaga, Wilmart;Song, So-Yeon;Park, Jin-Hong;Ryu, Jae-Jun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권6호
    • /
    • pp.408-414
    • /
    • 2018
  • PURPOSE. This study aimed to assess the effect of non-thermal plasma on the shear bond strength of resin cements to polyetherketoneketone (PEKK) in comparison to other surface treatment methods. MATERIALS AND METHODS. Eighty PEKK discs were subjected to different surface treatments: (1) Untreated (UT); (2) Non-thermal plasma (NTP); (3) Sandblasting with $50{\mu}m$ $Al_2O_3$ particles (SB); and (4) Sandblasting + Non-thermal plasma (SB+NTP). After each surface treatment, the contact angle was measured. Surface conditioning with Visio.Link was applied in all groups after pre-treatment. RelyX Unicem resin cement was bonded onto the PEKK specimens. After fabrication of the specimens, half of each group (n=10) was initially tested, while the other half was subjected to thermocycling ($5^{\circ}C$ to $55^{\circ}C$ at 10,000 cycles). Shear bond strength (SBS) testing was performed using a universal testing machine, and failure modes were assessed using stereomicroscopy. The SBS results were analyzed statistically using one-way ANOVA followed by Tukey's post hoc test. Independent t-test was used to examine the effect of thermocycling (P<.05). RESULTS. The highest SBS values with or without thermocycling were observed with PEKK specimens that were treated with SB+NTP followed by the SB group. The lowest SBS results were observed in the UT groups. CONCLUSION. The shear bond strength between PEKK and resin cements was improved using non-thermal plasma treatment in combination with sandblasting.