• 제목/요약/키워드: Shear Load

검색결과 2,635건 처리시간 0.029초

Headed Shear Bar를 사용한 콘크리트 보의 반복 하중 실험 (Repeated Loading Tests of Reinforced Concrete Beams Containing Headed Shear Reinforcement)

  • 김영훈;윤영수;데니스미첼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.512-517
    • /
    • 2003
  • The repeated loading responses of four shear-critical reinforced concrete beams, with two different shear span-to-depth ratios, were studied. One series of beams was reinforced using pairs of bundled stirrups with $90^{\circ}C$ standard hooks, having free end extensions of $6d_b$. The companion beams contained shear reinforcement made with larger diameter headed bars anchored with 50mm diameter circular heads. A single headed bar had the same area as a pair of bundled stirrups and hence the two series were comparable. The test results indicate that beams containing headed bar stirrups have a superior performance to companion beams containing bundled standard stirrups, with improved ductility, larger energy adsorption and enhanced post-peak load carrying capability. Due to splitting of the concrete cover and local crushing, the hooks of the standard stirrups opened, resulting in loss of anchorage. In contrast, the headed bar stirrups did not lose their anchorage and hence were able to develop strain hardening and also served to delay buckling of the flexural compression steel. Excellent load-deflection predictions were obtained by reducing the tension stiffening to account for repeated load effects.

  • PDF

플랫 플레이트 구조의 기둥.슬래브 접합부 연성에 관한 연구 (Ductility of Column-Slab eoint in R/C Flat Plate System)

  • 김형기;박복만
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.113-119
    • /
    • 2000
  • The R/C flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problems in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab joint. Recently, the flat plate system accompanied with shear walls to resist the lateral loads is applied to high-rise buidings. Although the flat plate system is not considered in design as part of the lateral load-resisting system, it is required that this system keeps the ductile behavior for the lateral displacement of the building. However, it is unclear whether the column-slab joint possesses ductility enough to survive the lateral deformation. The objective of this paper is to investigate the major parameters that influence the ductility of R/C flat plate system by examining the existing experiments on column-slab joint. The effects of gravity load and shear reinforcement on the ductility of the flat plate system are presented.

Experimental and numerical study of shear crack propagation in concrete specimens

  • Haeri, Hadi;Sarfarazi, Vahab;Shemirani, Alireza Bagher
    • Computers and Concrete
    • /
    • 제20권1호
    • /
    • pp.57-63
    • /
    • 2017
  • A coupled experimental-numerical study on shear fracture in concrete specimens with different geometries is carried out. The crack initiation, propagation and final breakage of concrete specimens are experimentally studied under compression loading. The load-strain and the strength of the specimens are experimentally measured, indicating decreasing effects of the shear behavior on the failure load of the specimen. The effects of specimen geometries on the shear fracturing path in the concrete specimens are also investigate. Numerical models using an indirect boundary element method are made to evaluate the crack propagation paths of concrete specimens. These numerical results are compared with the performed experiments and are validated experimentally.

Evaluation of Shear-Induced Phase Transformation of $\beta$-Cristobalite by Fiber Push-Out Technique

  • Sang Jin Lee;Dong Zhu;Jae Suk Sung
    • The Korean Journal of Ceramics
    • /
    • 제3권3호
    • /
    • pp.208-212
    • /
    • 1997
  • Shear-induced phase transformation behavior of chemically stabilized $\beta$-cristobalite was studied by the fiber push-out technique. To obtain the critical grain size for phase transformation, the hot-pressed polycrystalline $\beta$-cristobalite, which was used as the interphase between fiber and matrix, was annealed at $1300^{\circ}C$ for 10h. Two types of fibers, mullite and sapphire fiber, were used in this study. Debonding between mullite fiber and cristobalite interphase occurred at a critical load of 230 MPa. Static friction and fiber sliding were continuously followed by debonding. Shear-induced transformation induced cracks in the cristobalite interphase at the debonding stage. In the case of the sapphire fiber, the debonding occurred at a lower load of 180 MPa due to the residual stress in the interface caused by the difference in thermal expansion coefficients between the fiber and the cristobalite interphase. The load was insufficient for shear-induced phase transformation.

  • PDF

강섬유를 혼입한 고강도 콘크리트 보의 전단강도 (Shear Strength of High Strength Concrete Beams with Steel Fibrous)

  • 곽계환;박종건;정태영
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.23-30
    • /
    • 2000
  • The purpose of this paper is to study on the shear strength of high strength concrete beams with steel fibrous. In general, the shear strength of reinforced concrete beams is affected by the compressive strengths of concrete( c), the shear span-depth ratio(a/d), the longitudinal steel ratio($\rho$ $\omega$), and shear reinforcement. An experimental investigation of the shear strength of high strength concrete beams with steel fibrous was conducted. In each series the shear span-depth ratio(a/d) was held constant at 1.5, 2.8, or 3.6, while concrete strengths were varied from 320 to 520, to 800kgf/$\textrm{cm}^2$. To verify the proposed equations the experimental results were compared with those from other researches such as equation of ACI code 318-95 or equation of Zsutty. To deduce equation for shear strength from experimental data carried out MINITAP program. According to the experimental results, the addition of steel fibrous has increased the deflection and strain at failure load, improving the brittleness of the high strength concrete.

Analysis of reinforced concrete corbel beams using Strut and Tie models

  • Parol, Jafarali;Al-Qazweeni, Jamal;Salam, Safaa Abdul
    • Computers and Concrete
    • /
    • 제21권1호
    • /
    • pp.95-102
    • /
    • 2018
  • Reinforced concrete corbel beams (span to depth ratio of a corbel is less than one) are designed with primary reinforcement bars to account for bending moment and with the secondary reinforcement placed parallel to the primary reinforcement (shear stirrups) to resist shear force. It is interesting to note that most of the available analytical procedures employ empirical formulas for the analysis of reinforced concrete corbels. In the present work, a generalized and a simple strut and tie models were employed for the analysis of reinforced corbel beams. The models were benchmarked against experimental results available in the literature. It was shown here that increase of shear stirrups increases the load carrying capacity of reinforced concrete corbel beams. The effect of horizontal load on the load carrying capacity of the corbel beams has also been examined in the present paper. It is observed from the strut and tie models that the resistance of the corbel beam subjected to combined horizontal and vertical load did not change with increase in shear stirrups if the failure of the corbel is limited by concrete crushing. In other words, the load carrying capacity was independent of the horizontal load when failure of the beam occurred due to concrete crushing.

철근 콘크리트 기둥의 휨-전단 파괴거동에 관한 연구 (Flexural-Shear Behavior for RC Columns)

  • 이수곤;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.393-396
    • /
    • 1999
  • This paper presents a truss model for RC columns subjected to axial load and lateral load. The presented model is based on a stress field for the flexural-shear failure of short columns, which represent shear failure and bond splitting failure. Using this model, failure strength and related deformation of RC columns are investigated. Particular emphasis is placed on models capable of representing the interaction between deformation and shear strength.

  • PDF

전단변형을 고려한 이방성 적층판의 좌굴해석 (Buckling Analysis of Anisotropic Laminated Plates with Shear Deformation)

  • 최용희;권택진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.361-368
    • /
    • 2001
  • This paper deals with the buckling load of antisymmetric angle-ply and cross-ply laminated rectangular plates. Buckling analysis is preformed for a simply supported, shear deformable laminated plate subjected to uniaxial compression and biaxial compression combined with uniform lateral pression. The shear deformation theory is considered to figure out a more exact behavior of laminated plates exactly. The purposes of this study are to formulate anisotropic laminated plates with shear deformation and to investigate the buckling load according to the various variables of laminated plates by using the exact solutions for anisotropic laminated plates having simply supported boundary.

  • PDF

샌드위치식 복합구조체의 셀(Cell)형상비가 거동과 성능에 미치는 영향 (Effect of Span-to-Depth Ratio on Behavior and Capacity in Composite Structure of Sandwich System)

  • 정연주;정광회;김병석;박성수;황일선
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.73-78
    • /
    • 2000
  • This paper describes the effect of span-to-depth ratio, which describes aspect of cell formed with top diaphragm steel plate, on capacity in composite steel-concrete structure of sandwich system. The span-to-depth ratio \ulcorner load-carrying mechanism and load-distribution capacity of structure. Therefore, stress levels of members and load-resis\ulcorner of system vary according to span-depth ratio. In this study, numerical nonlinear analysis was performed to various ratio for two types(MA, MB) composite structure of sandwich system to analyze the influence of span-to-depth ratio or, behavior. The difference of load-carrying mechanism and stress of members results from analysis results, then bas\ulcorner differences, the effects of span-to-depth ratio on shear capacity, flexural capacity and load-resistance capacity were analyze effects on failure mode and ductility were briefly. As a results of this study, as span-to-depth ratio increases, \ulcorner bottom steel plate and concrete lower. This implies an increase in effective flexural and shear capacity. Therefore lo\ulcorner capacity of structure improves as span-to-depth ratio increases, Especially, the effect is greate in shear than flexural span-to-depth ratio increases, this difference between flexural and shear capacity may change failure mode and ductility. span-to-depth ratio increases capacity increases more than flexural capacity, we should expect that structural behavior mode gradually change from shear to flexural and ductility of structure gradually improves.

  • PDF

Hollow core 슬래브 간 접합부의 전단저항성능 평가 (Shear Performance Evaluation of the Joint between Hollow Core Slabs)

  • 홍건호;백종삼;박홍근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.94-101
    • /
    • 2010
  • 최근 건설공사의 공기단축을 위하여 프리캐스트 콘크리트(Precast Concrete)에 대한 관심이 점차 증가하는 추세이다. 본 연구에서는 프리캐스트 콘크리트 중 내부에 중공을 설치하여 중량을 감소시킨 할로우코어 슬래브 간의 접합부 전단성능 평가에 대한 실험적 연구를 수행하였다. 실험의 주요 변수는 할로우코어 슬래브 상부의 토핑콘크리트의 두께와 와이어메쉬의 배근유무이며, 총 8개의 슬래브간 접합부 실험체 중 4개의 면내전단실험과 4개의 면외방향 전단실험을 수행하였다. 실험의 결과는 균열하중, 파괴하중, 파괴양상, 강성 및 연성도의 측면에서 분석하였으며, 실험결과를 설계하중과 비교 검토함으로써 최적의 디테일을 개발할 수 있는 실험적 근거를 제공하도록 하였다. 실험결과, 슬래브 간 접합부에 무수축 모르타르를 타설한 경우에는 토핑두께 30mm의 보통 콘크리트를 사용한 것과 유사한 구조성능을 발현할 수 있는 것으로 평가되었으며, 와이어메쉬의 보강효과는 내력 및 강성보다는 연성의 증가에 크게 기여하는 것으로 나타났다. 또한, 토핑콘크리트의 두께에 따른 설계하중과의 비교를 통하여 적절한 디테일 설계를 할 수 있는 기초적 자료를 제공하였다.