• Title/Summary/Keyword: Shape Space

Search Result 2,094, Processing Time 0.033 seconds

Study on Modal Test Method for Vibration Characteristics of the Cylindrical Structure Filled with Liquid (액체가 채워진 원통형 구조물의 진동 특성 규명을 위한 모달 시험 방법 연구)

  • Kim, Gen-Sang;Kim, Mun-Guk;Kim, In-Gul;Park, Jae-Sang;Park, Soon-Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.8
    • /
    • pp.621-630
    • /
    • 2018
  • In the case of launch vehicles using liquid fuel, natural frequency changes due to fuel consumption after launch, and a modal test is essential to investigate its effect. However, when relying on modal test to characterize the free vibration characteristics, the testing time is excessively increased and accuracy is reduced. Therefore, this paper suggests a modal test method with finite element analysis to overcome these drawbacks. A cylindrical structure filled with liquid are considered as a study model, and modal tests and finite element analyses are performed. The modal tests are conducted by an impulsive method using an impact hammer and accelerometers. Through the comparison of the modal test and the finite element analysis results, the validity of the proposed modal test method is verified. In addition, the free vibration characteristics and the tendency for the cylindrical structure according to the liquid filled ratio were investigated.

Design of the Blade-Type Optical Bench for Earth Observation Satellite (지구관측위성의 블레이드형 광학탑재체 지지구조물 설계)

  • Kim, Kyung-Won;Kim, Jin-Hee;Rhee, Ju-Hun;Jin, Ik-Min;Kim, Jong-Wo;Park, Jong-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.11
    • /
    • pp.88-94
    • /
    • 2005
  • This paper is a study on the blade-type optical bench satisfying stiffness and thermal pointing error requirements for earth observation satellite. According to shape requirements, optical bench is designed. Because it does not satisfy the stiffness requirement, the stiffener is added on the outer/inner area of optical bench. But it does not meet the thermal pointing error requirement. So symmetrical structure is suggested with platform support structure attached on the upper/lower part of platform. Although it has better value than previous case, it still does not meet the thermal pointing error requirement. Based on the results of prior cases, optical bench finally designed, which satisfied both the stiffness and thermal pointing error requirements. Next conclusions follow from this design. It is efficient to increase thickness of platform facesheet, add stiffener and increase blade number to raise stiffness. It is effective to connect component consisting of same material and design optical bench having symmetrical structure to lower thermal pointing error.

Study on development of data base system and pattern analysis of tunnel portal slope in Korea (국내 터널 갱구사면 데이터베이스관리 시스템 개발 및 상태평가 기법에 관한 연구)

  • Baek, Yong;Kwon, O-Il;Koo, Ho-Bon;Bae, Gyu-Jin;Lee, Seoung-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.3
    • /
    • pp.213-225
    • /
    • 2004
  • The number of tunnels are in fact increasing as a part of linear improvement project of general national highway and road enlargement and pavement project. Recently, collapses of portal slope are also occurring considerably, due to local raining from severe rain storm and abnormal weather. Accordingly, it was risen a necessity to efficiently respond to tunnel portal slope damage and maintenance in Korea and oversea nations. This paper is a basic proposal to execute a survey on the current status and state of the tunnel portal slopes that were already installed and are now being operated along general national highways, and also to execute state evaluation for the purpose of managing those effectively. As a research method, domestic tunnels were analyzed in accordance with geometrical shape such as access type, portal form, and tunnel type, etc. via field survey to analyze the types of tunnel portal slopes along national highways. State evaluation classification sheet is presented to divide classes for the danger state of the surveyed portal slopes, and then the related grades are divided. It is mainly aimed at classifying the tunnel portal slope along national highways with using this state evaluation, to use it as basic data so that continuous maintenance can be executed in the future in accordance with danger classes.

  • PDF

A numerical study on pull-out behaviour of cavern-type rock anchorages (수치해석에 의한 암반상의 지중정착식 앵커리지 인발 거동 연구)

  • Hong, Eun-Soo;Cho, Gye-Chun;Baak, Seng Hyoung;Park, Jae-Hyun;Chung, Moonkyung;Lee, Seong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.521-531
    • /
    • 2014
  • This paper is a study for behaviour of cavern type anchorage tunnels for suspension bridges with cable tension. Anchorage behaviour, design method for anchorage, and failure surface angle, ${\delta}$ are analyzed by comparing numerical analysis results and ultimate pullout capacities($P_u$) using bilinear corelation equation. Results show that design depths for cavern type anchorage tunnels are easily checked with linear relationships for $P/{\gamma}/H$ vs. displacement and $P_u/{\gamma}/H$ vs. H/b. The analysis results of maximum shear strain distribution and plastic status show that failure shapes are closer to circular arc model than soil cone model which frequently used. To an easy calculation of the ultimate pullout capacity, we propose a simple bilinear failure model in this study. The calculated ultimate pullout capacities from the proposed bilinear corelation equation using two failure angles results are similar to the ultimate pullout capacities from numerical analysis.

A study on the characteristics for aerodynamics at high speed in railway tunnels - focused on the micro pressure wave (고속주행시 철도터널내 공기압 특성에 관한 기초연구 - 미기압(MPW)을 중심으로)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.249-260
    • /
    • 2014
  • When a train enters the tunnel at high speed, the pressure wave occurs. When this pressure wave reaches at the exit of tunnel, some are either emitted to the outside or reflected in tunnel by the form of expansion wave. The wave emitted to the outside forms the impulsive pressure wave. This wave is called 'Micro Pressure Wave'. The micro pressure wave generates noise and vibration around a exit portal of tunnel. When it becomes worse, it causes anxiety for residents and damage to windows. Thus, it requires a counterplan and prediction about the micro pressure wave for high speed railway construction. In this paper, the effects of train head nose and tunnel portal shape were investigated by model test, measurement for the micro pressure wave at the operating tunnel as well as numerical analysis for the gradient of pressure wave in the tunnel. As results, a method for predicting the intensity of the micro pressure wave is suggested and then the intensity of the micro pressure wave is analyzed by the tunnel length and the cross-sectional area.

The Effects of Tunnel Geometrical Characteristics and Canopy Installation on the Ventilation and Fire Propagation (터널의 기하학적 형태 및 캐노피 설치가 터널 환기 및 화재 확산에 미치는 영향 분석)

  • Lee, Chang-Woo;Suh, Ki-Yoon;Kim, Jung-Wook
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.4
    • /
    • pp.325-334
    • /
    • 2006
  • Understanding the airflow characteristics within the canopy structure installed between closely adjacent tunnels either for light adaptation or for protection from snow hazards is required for the normal ventilation as well as safety system design. Grade, horizontal alignment, cross-sectional area and shape are known to substantially influence the fire smoke behavior and their influences raise great concern for the safety design. This paper aims at studying the effects of tunnel geometrical characteristics and canopy installation on the ventilation and fire propagation through CFD analysis. In the case of 145m long canopy, 50% opening ratio is preferred with respect to the airflow pattern and ventilation efficiency. When a 20MW fire occurs in a 1.8km-long tunnel and four 1250mm reversible jet fans are instantly turned on, smoke concentration at 40m downstream of the fire decrease 13% for the upgrade tunnel with 2% gradient and increases 20% for -2% gradient, compared to the standard horizontal tunnel. Backlayering is observed within 45m-long segment toward the entrance in 2% down-graded tunnel. In a rectangular tunnel, there is no significant difference of smoke concentration as well as velocity profile from the standard crown tunnel. Three-laned tunnel shows lower level of both profiles and backlayering is detected up to 50m upstream of the fire, while the risky situation rapidly disappears thereafter.

Effect of widening excavation in divergence section of a double-deck tunnel on its stability (복층터널 분기구 확폭구간 굴착에 따른 안정성 영향)

  • La, You-Sung;Kim, Yunhee;Lee, Kangil;Kim, Yongseong;Kim, Bumjoo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.4
    • /
    • pp.435-450
    • /
    • 2020
  • The divergence section of a double-deck tunnel can be divided into a 'widening pre-divergence section', a large cross-section with a cap shape and a 'post-divergence section' where the separation between the main and the branch tunnel is made. Since the cross-section of the widening pre-divergence section is considerably larger than that of the post-divergence section, the influence of excavation due to the different sizes and shapes in the cross-section should be considered in the examination of the tunnel stability. In this study, the effect of the preceding excavation, that is the excavation of the widening pre-divergence section, on excavation stability of the post-divergence section was examined by varying the excavation methods and bench lengths through 3D finite element analysis. The results showed that although the effects of the excavation methods and the bench lengths are not significant on the variation of principal stresses, the preceding excavation causes a relatively large variation on the stresses which may have an impact on the stability of the post-divergence section from the comparison of Stress-Strength Ratio (SSR) between the cases with and without the consideration of the preceding excavation effect by 2D finite element analysis.

A Study on Visual Comfort for Light Control Method of Applied Daylighting (자연채광방식의 응용에 따른 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Han, Sang-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.140-145
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The model claims that lighting in a room with a side-window are perceived as harmonious when the overall light distribution in the room is well approximated by a compound of lights from the window and the entire ceiling. The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, thetwo variables were used in this study. One was the ratio of thelight from the window and ceiling in the standard and evaluation box. The standard box was provided by the ratio of 20% to 40% from the window and 80% to 60% from the ceiling as two lighting ratio patterns [Wu20(=Cu80) and Wu40(=Cu60)]. And the evaluation box was provided by the light ratio of 0% to 40 from the window and 100% to 60% from the ceiling [Wcp0(=Ccp100), Wcp20(=Ccp80) and Wcp40(=Ccp60)]. The other variable was themean illuminance level in both boxes. Two level of mean illuminance (700lx and 300lx) were used in this experiment. Each lighting condition was established at equal horizontal mean illuminance level, held constant near 700lx or 300lx in both boxes. Both of them were similar in the shape of distribution when there were same ratios of lights from the window and the ceiling. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

  • PDF

FEM Electrical Resistivity Modeling in Cylindrical Coordinates (원통 좌표계에서의 전기비저항 유한요소 모델링)

  • Choi Wonseok;Kim Jung-Ho;Park KwonGyu;Kim Hak-Soo;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.206-216
    • /
    • 2002
  • The finite element method (FEM), a powerful numerical modeling tool for solving various engineering problems, is frequently applied to three-dimensional (3-D) modeling thanks to its capability of discretizing and simulating the shape of model with finite number of elements. Considering the accuracy of the solution and computing time in modeling of engineering problems, it is preferable to construct physical continuity and simplify mesh system. Although there exist systematic mesh generation systems for arbitrary shaped model, it is hard to model a simple cylinder in terms of 3-D coordinate system especially in the vicinity of the central axis. In this study I adopt cylindrical coordinate system for modeling the 3-D model space and define the origin of the coordinates with mathematically clear coordinate transformation. Since we can simulate the whole space with hexahedral elements, the cylindrical coordinate system is effective in handling the 3-D model structure. The 3-D do resistivity modeling scheme developed in this study provides basie principle for borehole-to-surface resistivity survey, which can be a useful tool for the application to environmental problem.

A Feasibility Study on Application of a Deep Convolutional Neural Network for Automatic Rock Type Classification (자동 암종 분류를 위한 딥러닝 영상처리 기법의 적용성 검토 연구)

  • Pham, Chuyen;Shin, Hyu-Soung
    • Tunnel and Underground Space
    • /
    • v.30 no.5
    • /
    • pp.462-472
    • /
    • 2020
  • Rock classification is fundamental discipline of exploring geological and geotechnical features in a site, which, however, may not be easy works because of high diversity of rock shape and color according to its origin, geological history and so on. With the great success of convolutional neural networks (CNN) in many different image-based classification tasks, there has been increasing interest in taking advantage of CNN to classify geological material. In this study, a feasibility of the deep CNN is investigated for automatically and accurately identifying rock types, focusing on the condition of various shapes and colors even in the same rock type. It can be further developed to a mobile application for assisting geologist in classifying rocks in fieldwork. The structure of CNN model used in this study is based on a deep residual neural network (ResNet), which is an ultra-deep CNN using in object detection and classification. The proposed CNN was trained on 10 typical rock types with an overall accuracy of 84% on the test set. The result demonstrates that the proposed approach is not only able to classify rock type using images, but also represents an improvement as taking highly diverse rock image dataset as input.