• Title/Summary/Keyword: Shaking-table test

Search Result 454, Processing Time 0.022 seconds

Noise Effects on Shaking Table Test of Structures (진동대를 이용한 구조물의 내진실험시 잡음의 영향에 관한 고찰)

  • 최인길
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.312-319
    • /
    • 1998
  • The effect of noise on the input motion for the seismic test of structures using shaking table was studied. Table motions usually contain high frequency contents which influence the PGA of input motions. It was shown that the noise influenced PGA much with minor changes in high frequency contents. The Butterworth bandpass filter can be effectively used. The adequacy of the table motion should be judged based on both the frequency contents and the PGA.

  • PDF

Shaking Table Test for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment (내진설계 되지 않은 공동주택의 진동대 실험에 의한 내진성능 평가)

  • Chung, Lan;Lee, Joung-Woo;Park, Tae-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.721-728
    • /
    • 2006
  • Earthquakes are reported thai building structures have been colossal damaged, but before 1988 designed structures which were not applicate seismic design code have no seismic performance. Especially, for the apartment structures were indicated that it have no resist wall element of earthquake before 1988 designed structures. We have to evaluate for seismic performance this structures, therefore it will be retrofitted for seismic index sufficient structures. We performed seismic performance evaluation for model structures by MIDAS which is general structure analysis software. In this study, it was performed shaking table test to evaluate model structure which is reinforcement concrete and 5 floors for seismic performance index. We made specimens by similar's law and tested shaking table test. In the shaking table test it is not performed prototype model test because of space and equipment condition. So we had made scale-down model for 1/5 by similar's law. That's why it needs for the evaluation of performance. However, it is not possible to do an experiment of prototype owing to the shortage of space and the limit of an experimental instrument in the shaking table test. Then, modeling and reducing the part of prototype do the experiment. In this experiment a shaking table test is done and seismic performance of model structures is evaluated by using similitude laws for scale down specimen. As a result it is proved that non-seismic design structures need to retrofit since seismic performance shows life safe grade in 0.12g of an earthquake.

Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof (기와집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Seismic Test of a Full Scale Model of Wood House with Tiled Roof (기와집 실물크기 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.368-373
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a full scale model of wood house with tiled roof was performed. Full scale model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof (초가집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Huh, Young-Chul;Jeon, Bong-Hee
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Shaking Table Test of 1/3-Scale 3-Story Sam-Hwan Camus Precast Concrete Model (1/3축소 3층 삼환까뮤 P.C 모델의 진동대 실험)

  • 이한선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.140-154
    • /
    • 1992
  • The objective of the research stated here was aimed at providing the information needed to establish the Korean Seismic Design Code Recommendations and Guides for precast concrete (P.C) large panel apartment buildings. This was accomplished by investigation and analysis of the response of P.C large panel structures subjected to shaking table excitation simulating earthquake ground motion. one of the test specimens used was 1/3-scaled 3-story box P.C model provided by Sam-Hwan Camus Corporation. The 4m $\times$4m shaking table was used to simulate the earthquake ground motion. the employed input accelerogram was the one recorded as Taft N21E component and the peak ground acceleration(PGA) was scaled depending on the desired level of seismic severity and the time according to dynamic similitude rule. Based on results obtained from shaking table test of this P.C model, the following conclusions were drawn . (1) As far as test specimen is concerned, the seismic safety factors turns out to be 7~8. (2)P.C model has damping ratio of about8% which is twice larger than in-situ R.C. structure. And (3)this model has global displacement ductility ratio of 2~3 through the energy dissipation by opening and sliding of joints.

  • PDF

Estimation of Aseismatic Performance of Laminated Rubber Bearing Through Shaking Table Tests (진동대 실험을 통한 적층고무받침의 내진성능 평가)

  • Park, Seong-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.440-446
    • /
    • 2010
  • This paper was investigated on the laminated rubber bearing, which mitigates damages of bridges from threat of earthquakes. Laminated rubber bearing can bear large loads for long periods of time and be capable of large deformations during an earthquake. To evaluate seismic isolation with laminated rubber bearing on several earthquake waves, we performed a shaking table test. In this test, deck acceleration was measured by accelerometers and shear force on piers was surveyed by load cells. Furthermore, seismic capacity of isolated systems with laminated rubber bearing was compared with non-isolated systems through shaking table test. The results show that deck acceleration and shear force were relatively reduced by laminated rubber bearing.

Simulation of the damping effect of a high-rise CRST frame structure

  • Lu, Xilin;Zhang, Hongmei;Meng, Chunguang
    • Computers and Concrete
    • /
    • v.9 no.4
    • /
    • pp.245-255
    • /
    • 2012
  • The damping effect of a Concrete-filled Rectangular Steel Tube (CRST) frame structure is studied in this paper. Viscous dampers are employed to insure the function of the building especially subjected to earthquakes, for some of the main vertical elements of the building are not continuous. The shaking table test of a 1:15 scale model was conducted under different earthquake excitations to recognize the seismic behavior of this building. And the vibration damping effect was also investigated by the shaking table test and the simulation analysis. The nonlinear time-history analysis of the shaking table test model was carried out by the finite element analysis program CANNY. The simulation model was constructed in accordance with the tested one and was analyzed under the same loading condition and the simulation effect was then validated by the tested results. Further more, the simulation analysis of the prototype structure was carried out by the same procedure. Both the simulated and tested results indicate that there are no obvious weak stories on the damping equipped structure, and the dampers can provide the probability of an irregular CRST frame structure to meet the requirements of the design code on energy dissipation and deformation limitation.

Evaluation of MCC seismic response according to the frequency contents through the shake table test

  • Chang, Sung-Jin;Jeong, Young-Soo;Eem, Seung-Hyun;Choi, In-Kil;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1345-1356
    • /
    • 2021
  • Damage to nuclear power plants causes human casualties and environmental disasters. There are electrical facilities that control safety-related devices in nuclear power plants, and seismic performance is required for them. The 2016 Gyeongju earthquake had many high-frequency components. Therefore, there is a high possibility that an earthquake involving many high frequency components will occur in South Korea. As such, it is necessary to examine the safety of nuclear power plants against an earthquake with many high-frequency components. In this study, the shaking table test of electrical facilities was conducted against the design earthquake for nuclear power plants with a large low-frequency components and an earthquake with a large high-frequency components. The response characteristics of the earthquake with a large high-frequency components were identified by deriving the amplification factors of the response through the shaking table test. In addition, safety of electrical facility against the two aforementioned types of earthquakes with different seismic characteristics was confirmed through limit-state seismic tests. The electrical facility that was performed to the shaking table test in this study was a motor control center (MCC).

Shaking Table Test of a Structure with Added Viscoelastic Dampers (점탄성 감쇠기가 설치된 구조물의 진동대 실험)

  • Kim., Jin-Koo;Kwon., Young-Jip
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.197-203
    • /
    • 2001
  • This study presents the results of shaking table test of scaled model structures with added viscoelastic dampers, which are considered to be one of the most efficient means of upgrading existing structures against seismic loads. The experimental results were compared with those from analysis based on the linear modeling of viscoelastic dampers. The parameters obtained from free vibration test were utilized in the analysis. According to the results the added viscoelastic dampers turned out to be effective in reducing the responses of the model structures. It was also found that the analysis with linear modeling of viscoelastic dampers could simulate the test results accurately.

  • PDF