• 제목/요약/키워드: Shaft Generator

검색결과 146건 처리시간 0.026초

회전축의 정밀 토그 발생용 직류 발전기 제어장치의 설계 및 성능평가에 관한 연구 (Design and Performance Evaluation of DC Generator Control System for Cortrolling Torque of Rotating Shaft)

  • 김갑순;강대임;안병덕
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.50-56
    • /
    • 1994
  • A DC generator control system was designed to control the torque of a rotating shaft precisely. The control system is composed of a strain gage type torque cell, a torque cell amplifier, a computer, a D/A converter, a error detector, a DC voltage amplifier and a resistor. The response test under unit step input and the dynamic stability test for the designed control system were carried out. It was confirmed that the settling time from the response test is about 4 s and the error from the dynamic stability test is less than 0.06% of rated output of torque cell. The designed control system may be used to control a DC generator which may be used to apply torque to a rotating shaft.

  • PDF

고효율 영구자석 여자기 구조의 발전기 설계와 전압제어 (A Design and Voltage Control of a High Efficiency Generator with PM Exciter)

  • 조영준;이동희
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1827-1834
    • /
    • 2016
  • This paper presents a high efficient generator with PM(Permanent Magnet) exciter. The proposed PM exciter for the generator can produce a linear output voltage according to the engine speed. This output voltage is directly used to control the field current of the generator to adjust the generator output voltage. In the proposed generator system, since the field winding current can be supplied by the PM exciter, the generator can self-start without any battery or an external power supply due to the low residential flux. Furthermore, the operating efficiency of the generator is higher than a conventional winding exciter. The main problem of the proposed generator system, the field winding current controller has to be embedded inside the generator, and it rotates according to the generator shaft. In this paper, the proper embedded current controller is designed for the proposed generator system. Due to the embedded controller cannot be connected to the outside the generator controller, the measured instantaneous output voltage of the generator is transferred by the photo isolated communication using shaft aligned infrared transmitter and receiver to keep the constant generator output voltage. In this paper, 10kW, 380V engine generator with PM exciter and the embedded DAVR(Digital Automatic Voltage Regulator) are described. The proposed high efficiency generator is simulated and tested to verify the effectiveness.

Control Design of the Brushless Doubly-Fed Machines for Stand-Alone VSCF Ship Shaft Generator Systems

  • Liu, Yi;Ai, Wu;Chen, Bing;Chen, Ke
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.259-267
    • /
    • 2016
  • This paper presents a stand-alone variable speed constant frequency (VSCF) ship shaft generator system based on a brushless doubly-fed machine (BDFM). In this system, the output voltage amplitude and frequency of the BDFM are kept constant under a variable rotor speed and load by utilizing a well-designed current vector controller to regulate the control winding (CW) current. The control scheme is proposed, and the hardware design for the control system is developed. The proposed generator system is tested on a 325 TEU container vessel, and the test results show the good dynamic performance of the CW current vector controller and the whole control system. A harmonic analysis of the output voltage and a fuel consumption analysis of the generator system are also implemented. Finally, the total efficiency of the generator system is presented under different rotor speeds and load conditions.

Simulink를 이용한 터그보트의 샤프트제너레이터 물리모델링 및 연료소모율 검증 시뮬레이션에 관한 연구 (A Study on the Physical Modeling of the Shaft Generator and the Fuel Consumption Verification Simulation of a Tugboat using Simulink)

  • 김성동;김남호
    • 융합신호처리학회논문지
    • /
    • 제22권1호
    • /
    • pp.7-13
    • /
    • 2021
  • 최근 해운산업에서는 환경규제에 대한 중요성이 높아지고 있으며, 이를 위한 산업의 요구가 급격히 높아지고 있다. 이에 샤프트제너레이터는 선박에 가장 빠르게 적용이 가능한 환경규제 대응기술로 선주의 요구가 증가하고 있다. 샤프트제너레이터는 메인추진엔진에 전동기를 설치하여, 부하환경에 따라 가변적으로 사용함으로 메인추진엔진의 연료소모율을 줄일 수 있는 장치이다. 저속에서는 모터의 힘으로 동작하고, 급격한 부하가 필요할 때에는 메인추진엔진과 모터가 함께 동작함으로 효율적인 운전이 가능하다. 본 논문에서는 MATLAB Simulink를 이용하여 터그보트의 디젤엔진과 샤프트제너레이터를 모델링하고, 시뮬레이션을 통해서 연료소모율을 검증하였다.

Mechatronic Control Model of the Wind Turbine with Transmission to Split Power

  • Zhang Tong;Li Wenyong;Du Yu
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권4호
    • /
    • pp.533-541
    • /
    • 2005
  • In this paper, a wind turbine with power splitting transmission, which is realized through a novel three-shaft planetary, is presented. The input shaft of the transmission is driven by the rotor of the wind turbine, the output shaft is connected to the grid via the main generator (asynchronous generator), and the third shaft is driven by a control motor with variable speed. The dynamic models of the sub systems of this wind turbine, e.g. the rotor aerodynamics, the drive train dynamics and the power generation unit dynamics, were given and linearized at an operating point. These sub models were integrated in a multidisciplinary dynamic model, which is suitable for control syntheses to optimize the utilization of wind energy and to reduce the excessive dynamic loads. The important dynamic behaviours were investigated and a wind turbine with a soft main shaft was recommend.

Resonance and Instability of Blade-Shaft Coupled Bending Vibrations with In-plane Blade Vibration

  • Anegawa, Norihisa;Fujiwara, Hiroyuki;Okabe, Akira;Matsushita, Osami
    • International Journal of Fluid Machinery and Systems
    • /
    • 제1권1호
    • /
    • pp.169-180
    • /
    • 2008
  • As a major component of a power plant, a turbine generator must have sufficient reliability. Longer blades have lower natural frequency, thereby requiring that the design of the shaft and blade takes into account the coupling of the blade vibration mode, nodal diameter k=0 and k=1 with vibration of the shaft. The present work analyzes the coupling of the translation motion of the shaft with in-plane vibration of the blades with k=1 modes. At a rotational speed ${\Omega}_1=|{\omega}_s-{\omega}_b|$, the resonance of the blades has a relatively large amplitude. A violent coupled resonance was observed at a rotational speed ${\Omega}_2=|{\omega}_s+{\omega}_b|$. Resonance in blade vibration at ${\Omega}_1=|{\omega}_s-{\omega}_b|$ was experimentally confirmed.

원전 터빈 발전기 비틀림 진동기준 국제표준규격(ISO 22266-1) 적용 사례 (Application Case of ISO 22266-1 for Establishing the Torsional Vibration Criteria of a Nuclear Turbine Generator)

  • 정혁진;송우석;이혁순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.225-226
    • /
    • 2010
  • ISO 22266-1 issued in May 2009 provides guidelines for applying shaft torsional vibration criteria, under normal operating conditions, for the coupled shaft system and long blades of a turbine generator set. In case that a turbine generator vendor do not meet the separation margin of torsional natural frequencies in the technical specifications of the purchaser, this standard can present the reasonable and objective criteria about torsional vibration which both purchaser and supplier can agree on, while ensuring the integrity of turbine generator. This paper describes the application case of ISO 22266-1 for the establishment of torsinal vibration criteria under retrofitting the turbine generator of 'U' nuclear power plant.

  • PDF

6 MW급 해상풍력발전기용 고속축커플링 개발 (Development of High-speed Shaft Coupling for 6 MW Class Offshore Wind Turbine)

  • 박수근;이형우
    • 풍력에너지저널
    • /
    • 제10권4호
    • /
    • pp.20-27
    • /
    • 2019
  • High-speed shaft coupling in a wind power system transmits power and absorbs variations in length and spindle dislocation between the gearbox and generator. Furthermore, the coupling has an insulation function that prevents electrical corrosion caused by the flow of the generator's current into the gearbox and prevents overload resulting from sudden power failure from being transferred to the gearbox. Its design, functions, and part verification are described in the IEC61400 and GL Guidelines, which specify that the part must have a durability life of 20 years or longer under distance variation and axial misalignment between the gearbox and the generator. This study presents the design of a high-speed coupling through composite stiffness calculation, structural analysis, and comparative analysis of test and theory to identify the characteristics of high-speed coupling for a large-capacity 6 MW wind power generator. A prototype was fabricated by optimizing the manufacturing process for each part based on the design, and the reliability of the fabricated prototype was verified by evaluating the performance of the target quantitative evaluation items.

선박용 발전기 동기화시의 과도현상 해석에 관한 연구 (A Study on the Transient Phenomenon Analysis of Ship Generator Synchronization)

  • 오세진;김종수;김성환;이성근;조성갑
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.998-1004
    • /
    • 2007
  • Connecting a synchronous generator to a power system is a dynamic process, requiring the coordinated operation of many components and systems. The goal is to connect the oncoming generator to the system smoothly i.e without causing any significant bumps, surges, or power swings, by closing the ACB when the oncoming generator matches the power system in voltage magnitude, phase angle, and frequency. If oncoming generator voltage is not matched to the power system voltage, reactive power will flow either into or out of the system at the instant of ACB closure. If this voltage difference is too great, the reactive power flow may result in high transient stresses that could damage the windings of the generator. Also, if oncoming generator frequency is not matched to the power system frequency, transient power will flow between generator and power system. If the frequency difference is too great, the transient power flow is reflected into the prime mover shaft, and this may result in excessive shaft or coupling stress. This paper tries to prove the necessity of correct synchronization for ship generators through a transient phenomenon analysis.