Analysis of Storm Water Run-off Characteristics during Wet Weather (강우시 합류식 하수관거의 유출특성 분석)

  • Choi, Sung-Hyun;Choi, Seung-Chol;Park, Eun-Young;Rim, Jay-Myoung
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.95-101
    • /
    • 2002
  • Much of domestic city is served by combined sewer system rather than separate sanitary or storm sewers. During wet weather, when the volume of sanitary sewage and storm water entering the combined sewers exceeds the system capacity, the system is designed to overflow at several designated CSOs. The objective of this research is to have grasp of characteristics of combined sewer runoff and to evaluate efficiently the intercepted volume of CSOs. During the wet weather in first rainfall, SS load at each site H-1, H-2, and H-3 were 600kg/event, 370kg/event, and 289kg/event, SS load at each site in second rainfall were 216kg/event, 113kg/event, and 37.2kg/event. EMCs at each site were 702mg/L, 816mg/L, 861mg/L in first rainfall and 99.9mg/L, 161.9mg/L, 103.6mg/L in second rainfall, respectively. First flush coefficients b at each site were 0.237, 0.166, and 0.151.

  • PDF

Risk Evaluation of Tree Root Intrusion into Sewer Network (하수관망의 나무뿌리 침입 리스크 평가)

  • Han, Sangjong;Shin, Hyunjun;Hwang, Hwankook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.693-702
    • /
    • 2015
  • The objective of this study is to investigate and evaluate that a roadside tree root intrudes sewer network systems. Two approaches were performed to assess the characteristics of tree root intrusion. First, the characteristics of tree roots that had invaded sewers were directly observed by means of closed-circuit television inspection robot. Second, the intrusion proportions of tree root into rain gutters in the sampling area were investigated. As tree species of low intrusion proportions, the results indicated that Ginkgo biloba Linn. and Acer buergerianum Miq. were 1.7% and 4.3%. On the other hand, tree species of high intrusion proportions were Metasequoia glyptostroboides Hu et Cheng, Ulmus davidiana var. japonica Nakai and Zelkova serrata Makino as 22.2%, 20.4%, and 17.6% respectively. In particular, sewers and gutters around Zelkova species should be the focus of maintenance work because of the high proportion of these trees on roadsides.

Optimum Flow and Pollution Load Monitoring Time of Combined Sewers of Urban Watersheds during Dry Weather (비강우시 도시 합류식 하수도의 오염부하 산정을 위한 최적관측시간 산정연구)

  • Choi, Yong-Hun;Won, Chul-Hee;Park, Woon-Ji;Seo, Ji-Yeon;Shin, Min-Hwan;Lee, Chan-Ki;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.3
    • /
    • pp.9-14
    • /
    • 2009
  • Flow and pollution load were monitored at 2 combined sewer outlets (C-1 and C-2) of urban watersheds during dry weather from September, 2004 to April, 2006 for 20 months. The objectives were to investigate the diurnal variation of flow and pollutant load and to find the proper sampling time that could measure representative flow and pollutant load. Pollution load closed to the average daily load at C-1 could be measured at 00:00 hour and by the mean of 15:00 and 18:00 hour measures, and 15:00 and 21:00 hour measures, respectively. In addition at C-2, it was 21:00 hour and the mean of 15:00 and 18:00 hour measures. This study concluded that arbitrary sampling of flow and water quality could cause large errors in the estimation of urban pollution load and recommended that urban combined sewers should be monitored when flow and water quality showed daily average and concentration.

Cause Analysis for Reduced Effect of Sewer Pipe Improvement Project Based On Investigation of Interceptor Sewers (차집관로의 조사 및 분석을 통한 하수관로정비 사업의 효과 감소 원인 분석)

  • Chae, Myungbyung;Bae, Younghye;Kim, Hungsoo
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.219-226
    • /
    • 2018
  • Interceptor sewer is installed underground near to the river side mostly ofstate-owned land and the management efficiency of public sewage disposal facilities is decreasing as too much infiltration/inflow(I/I) and river flow to interceptor sewer are caused by broken or deteriorated sewer. This also affects the sewer pipeline project and decreases its efficiency. Therefore, the aim of this study is to investigate interceptor sewer which has influence on the reduction of the project effect. The investigation were performed for three study areas. The study includes the investigation of current condition of interceptor sewer(sewer extension, pipe diameter, pipe type, installed year, installed locations, etc), investigation of inside of sewer by CCTV accompanied by pumping and dredging works where required, investigation of inside of manholes by eyes, calculation of pollutant load using the results of investigation of flow quantity and quality. Multipoint investigations were simultaneously performed for flow quantity at confluence area and other investigations were also performed for flow quantity and BOD for interceptor sewer and comparison of pollutant load, investigation of infiltration/inflow(I/I) caused by deterioration of interceptor sewer. As the result of the study, a main reason for reduced effect of sewer pipe improvement project was analyzed as the low-density sewage and I/I in public seweage treatment Facility due to deteriorated and unmanaged interceptor sewers.

The Renewal Methods for Rehabilitation of Deteriorated Severs(V) - The Construction Manual of Reconstruction Methods for Sewers (내약품성이 강화된 경질염화비닐재와 고점성 모르타르 및 특수제관장치를 사용한 상하수시설의 리뉴얼공법(V) -리플래시재구축공법의 시공매뉴얼의 작성-)

The System of Sewage and Domestic Wastewater Treatment Plants in Tan-Sui River Basin

  • Ko, Chun-Han
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.26.2-39
    • /
    • 2002
  • Tan-Sui River Basin covers Taipei metropolitan area of 2,726 square kilometers with more than six million residents. Since 1988, Taiwan government started to plan and construct an integrated sewerage system, consisted by both separated and concentrated trunk sewers, wastewater treatment plants and ocean outfalls. This presentation will introduce the master plan and major facilities of Tan-Sui River Basin sewerage system. Other measures to protect general water quality and the environment of adjacent river basin area of Tan-Sui River and her tributaries by Taiwan EPA will be presented as well.

  • PDF

Development and Verification of Inundation Modeling with Urban Flooding Caused by the Surcharge of Storm Sewers (도시배수체계와 연계한 내수침수모형의 개발 및 검증)

  • Kim, Ji-Sung;Han, Kun-Yeun;Lee, Chang-Hee
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.12 s.173
    • /
    • pp.1013-1022
    • /
    • 2006
  • Urban flooding is usually caused by the surcharge of storm sewers. For this reason, previous studies on urban flooding are mainly concentrated on the simulation of urban drainage systems. However these approaches that find the pipes which have insufficient drainage capacity are very approximate and unreasonable ways in establishing both flood prevention and flood-loss reduction planning. In this study, a two-dimensional model linked the existing ILLUDAS model is developed to calculate the accurate and resonable solution about urban flood inundation and it is verified by using the simulation of July 2001 flood in Seoul. In the urban area with a small difference of ground elevations, the two-dimensional flood propagation phases must be considered to make a accurate analysis for inundated area and depth. The result of this study can be used to construct fundamental data for a flood control plan and establish a urban flood forecasting/warning system.

The application of reliability analysis for the design of storm sewer (우수관의 설계를 위한 신뢰성해석기법의 적용)

  • Kwon, Hyuk Jaea;Lee, Kyung Je
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.10
    • /
    • pp.887-893
    • /
    • 2018
  • In this study, the optimum design technology is suggested by using reliability analysis method. Nowadays, urban flood inundation is easily occurred because of local heavy rain. Traditional deterministic design method for storm sewer may underestimate the size of pipe. Therefore, stochastic method for the storm sewer design is necessary to solve this problem. In the present study, reliability model using FORM (First Order Reliability Method) was developed for the storm sewer. Developed model was applied to the real storm sewers of 5 different areas. Probability of exceeding capacity has been calculated and construction costs according to diameter have been compared. Probability of exceeding capacity of storm sewers of 5 areas have been calculated after estimating the return period of rainfall intensity.

Optimal Sizing of Intercepting Flow for Reducing Pollution Loads Caused by CSOs (CSOs 저감을 위한 차집관거 최적화 시스템)

  • Kong, Min-Keun;Bae, Ki-Hyun;Kang, Woo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.418-424
    • /
    • 2004
  • An abrupt high pollution loads in combined sewer systems is believed to be caused by first flushing actions and the resuspension of sediments deposited in sewers. Therefore, pollution loads in each flow regulator have a different tendency. This systems control intercepting flow in each flow regulator using water quality and water level. A desired quantity of intercepting flow was adjusted and the necessary slide position for a constant intercepting is calculated by Optimization programming. This systems make it possible to reduce pollution loads caused by CSOs to water body, may be alternative for the stable operation of STP through improving water quality to STP.