• 제목/요약/키워드: Sewage treatment water

검색결과 713건 처리시간 0.028초

개발도상국 중국의 하수처리장 운영.관리능 평가 (O&M Evaluating for Sewage Treatment Plants in China as a Developing Country)

  • 김연권;문용택;김홍석;김지연
    • 환경위생공학
    • /
    • 제21권3호
    • /
    • pp.27-36
    • /
    • 2006
  • For the last 20 years, China has transformed itself from a rural economy into an industrial giant, averaging over 8 % annual growth of GDP. Unfortunately, this rapid growth has taken a significant toll on its natural resource base as well, particularly water resources. These problems have been exacerbated by a low level of sewage treatment technology and by the operating and maintenance (O&M). In case of urban areas, most big cities in China have a well functioning sewage system comprised of sewers and sewage treatment plants (STPs). Nevertheless, the existing STPs are still not capable of properly treating the sewage, both quantitatively and qualitatively. The rural areas in China cover a large land, with two-third of the nation's population. The low educational and poor economic states make it hard to process self-protection and management. In the surveyed area in Henan, there was no STPs put into use as of 2004, and the sewer lines are not well organized. The big issue for the currently planned STPs is the collection system not included in the plans.

하수처리 공정시스템에서 유량제어기법의 활용에 관한 연구 (A Study on the applications of flow control methods in sewage treatment process system)

  • 정성윤;강선홍
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.597-604
    • /
    • 2016
  • This study was begun with the object of actively reflection the rapid technological advancements of the electronical control and mechanical control industries to sewage disposal methods. Or focuses on applying a flow control method that utilizes inverters and automatic valves to sewage treatment process systems. This study proposes that sewage treatment process systems architects must acquire a certain degree of technical skills in the areas of electrical and mechanical controls in order to raise the standard of completeness of sewage treatment process systems. And further emphasizes that there is required continuous research on automatics valves that are used in sewage treatment.

NIER-MASS 프로그램을 이용한 가축매립지 침출수 연계처리 방안 연구 (A Study on Treatment Measures of Carcass Disposal Site Leachate into the Livestock Manure and Sewage Treatment Facilities using NIER-MASS program)

  • 정동환;이철구;신진수;김현우;윤수향;김용석;유순주;김신조
    • 환경영향평가
    • /
    • 제21권5호
    • /
    • pp.725-734
    • /
    • 2012
  • The outbreak of foot and mouth disease in November 2010 raised many social, economic and environmental issues and water contaminations by leachate from carcass disposal sites particularly emerged as a serious concern. In oder to efficiently handle these problems, a critical method is required to transport leachate to livestock manure and sewage treatment plants and purify it. This study aims to present the best applicable method to transport leachate from carcass disposal sites into livestock manure and sewage treatment facilities. We investigated the biological and chemical characteristics such as BOD, COD, SS, TN, TP and Total coliforms. Current conjugated treatments in livestock manure and sewage treatment plants was studied by surveying the operations of those facilities. The NIER-MASS(National Institute of Environmental Research - Mass Balance Evaluation System of Sewage Treatment Facilities) program was applied to present the best conjugated treatment method through estimating the maximum daily load to meet the water quality standards in effluent.

상하수처리용 교반기의 설계 방법 연구 (A Study on the Design Method of Mixers for Water&Sewage water treatment)

  • 이혜영;주윤식;강문후
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.427-430
    • /
    • 2003
  • The Mixers is used for the Mixing which is the most important process in the Water&Sewage water treatment. To choose proper mixer required much career and knowledge, to check many elements which are purpose, time and condition of mixing. Thus, the design method of mixers is to be utilized for the structural design of the water & Sewage water treatment.

  • PDF

강원 영서지역 하수처리장이 수질에 미치는 영향 (Effect of Municipal Sewage Treatment Plant on Water Quality in Western Kangwon Area)

  • 허인량;최지용;김영진;정의호
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.235-240
    • /
    • 2005
  • The effects of municipal sewage treatment plants on the water quality and effluent loading were investigated. BOD removal rates from Wonju, Hoengseong, and Hongcheon municipal sewage treatment plants were $88.9\%,\;80.6\%,\;90.7\%$ and T-P removal rates were $47.3\%,\;56.5\%,\;71.6\%,$ respectively. Also, BOD effluent leading from WonJu, Hoengseong, and Hongcheon treatment plants were 1,520 kg/day, 75 kg/day, 55 kg/day and T-P effluent loading were 203.9 kg/day, 4.2 kg/day, 4.0 kg/day, respectively. In terms of water quality distribution by distance of flow, BOD of the Seom river rapidly rose from 1.6 mg/l to 4.0 mg/l and T-P rose from 0.034 mg/l to 0.321 mg/l. Also BOD of the Hongcheon river showed a slowly rise from 1.1 mg/l to 1.4 mg/l and T-P from 0.011 mg/l to 0.026 mg/l. In conclusion, the effects of municipal sewage treatment plants on the water quality proved that T-P was higher than BOD. Consequently, in order to improve water quality, it is necessary to adopt an advanced sewage treatment system like nutrient removal.

분류식 하수관거에서의 고도하수처리공법 적용성 해석 (Application analysis of advanced sewage treatment on the separated sewer pipe)

  • 박수진;고종섭;백경원;최한규
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.772-777
    • /
    • 2012
  • In order to examine the tailorability of advanced sewage treatment of a separated sewer pipe, we observed the quality of leaked water in a reactor. A2C affiliation and MBR affiliation decreased by over 78% in cases of BOD, COD, and SS. SBR affiliation decreased by 79.1% in a case of T-N. Overall, the efficiency of T-N on the above affiliations was low. SS had the high efficiency in MBR affiliation. In the end, examination of water quality improvement showed that the quality was improved from 20% to 90%; hence, it is expected that this treatment can protect the water resources of the Hongcheon River and makes it easier to use the water of the river.

  • PDF

하수처리 활성오니공정의 에너지 절감을 위한 퍼지 제어 방법에 관한 연구 (A Study on Fuzzy Control Method of Energy Saving for Activated Sludge Process in Sewage Treatment Plant)

  • 남의석
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1477-1485
    • /
    • 2018
  • There are two major issues for activated sludge process in sewage treatment plant. One is how to make sewage be more clean and the other is the energy saving in sewage treatment process. The major monitoring sewage qualities are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent. These are transmitted to the national TMS(Telemetry Monitoring System) at every hour. If these exceed the environmental standard, the environmental charges imposed. So, these water qualities are to be controlled below the environmental standard in operation of sewage treatment plant. And recently, the energy saving is also important in process operation. Over 50% energy is consumed in blowers and motors for injection oxygen into aeration tank. So, with the water qualities to be controlled below the environmental standard, the energy saving also is to be accomplished for efficient plant management. Almost researches are aimed to control water quality without considering energy saving. AI techniques have been used for control water quality. AI modeling simulator provided the optimal control inputs(blower speed, waste sludge, return sludge) for control water quality. Blower speed is the main control input for activated sludge process. To make sewage be more clean, the excessive blower speed is supplied, but water quality is not better than the previous. In results, non necessary energy is consumed. In this paper we propose a new method that the energy saving also is to be accomplished with the water qualities to be controlled below the environmental standard for efficient plant management. Water qualities in only aeration tank are used the inputs of fuzzy models. Outputs of these models are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent and have the environmental standards. In test, we found this method could save 10% energy than the previous methods.

생활배수처리시설의 정비와 금후의 방향 (Estabilishment of Community plant)

  • 김경호
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.27-30
    • /
    • 1991
  • Since the diffusion rate of sewage treatment plant is about 30% of the country. It is not enough to cope with entire sewage treatment of the community. Therefore, the septic tank is introduced which is connected with water flush toilet only. It is estimated that the large portion of water pollution has occured due to untreated sewage such as pollutants of kitchen, laundry and bathtub water, etc., which are not go through the existing septic tank. However, the construction of community plant which is could treat most of household run sewage should have flexibility in type, treatment method, effectiveness and economy which are adoption of the community. Without the treatment of combined household run sewage, the improvement of water pollution will be hardly expected.

  • PDF

Optimum Sewage Discharge Strategy for Coastal Waters

  • Kang, Yun-Ho;Lee, Moon-Ock
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제10권S_3호
    • /
    • pp.97-106
    • /
    • 2001
  • To improve the water quality, particularly for sea bathers, the behaviour of wastewater from sewage outfalls in water adjacent to Swansea, UK, was studied using a mathematical model. The water quality in the sewage receiving basin was determined using factors like the outfall diffuser location(distance from land boundary), sewage treatment scheme, discharge time, and bacteria decay rate, etc. With respect to these factors, an optimal strategy for sewage discharge was then investigated to minimize bacteria levels along the bathing beaches. As water quality criteria, predicted faecal coliform levels were monitored along the coast adjacent to the outfall locations. The resultant values were compared with EC Mandatory(<2000, 95 % of 20 samples) and Guideline Standards(< 100, 80 % of 20 samples). For the advective-diffusion equation, the non linear advective terms were represented using the ULTIMATE algorithm and the third-order accurate QUICKEST scheme to avoid numerical diffusion. Details of the simulation results are then presented as an optimal policy for sewage discharge in the region.

  • PDF

고도하수처리공법을 적용한 마을 하수도의 수질개선 평가 (Water Quality Improvement Evaluation of Community Sewerage by using Advanced Sewage Treatment)

  • 최한규;고종섭;박수진
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.57-64
    • /
    • 2012
  • In order to examine the tailorability of advanced sewage treatment of a separated sewer pipe, we observed the quality of leaked water in a reactor. A2C affiliation and MBR affiliation decreased by over 78% in cases of BOD, COD, and SS. SBR affiliation decreased by 79.1% in a case of T-N. Overall, the efficiency of T-N on the above affiliations was low. SS had the high efficiency in MBR affiliation. In the end, examination of water quality improvement showed that the quality was improved from 20% to 90%; hence, it is expected that this treatment can protect the water resources of the Hongcheon River and makes it easier to use the water of the river.

  • PDF