• 제목/요약/키워드: Sewage reuse

검색결과 72건 처리시간 0.023초

농촌오수 처리수의 농업용수로의 재이용 가능성에 관한 연구 (Feasibility Study on the Reuse of Treated Sewage Effluent for Agrcultural Water)

  • 권태영;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.663-669
    • /
    • 1999
  • The objective of this study are to examine the feasbility of reuse treated sewage effluent ofr agricultural water, and to obtain basic data for estabilishment of rational agricultural water quality standard. From this study, it appears that reuse of treated sewage as a supplemental irrigation water could be feasible and practical alternative for ultimate sewage disposal which often causes water quality problem to the receiving water body. For full scale applicatiion, further study is recommended on the secific guidelines of major water quality components and publc health.

  • PDF

비료 유도용액의 정삼투를 이용한 하수의 재이용 및 농축 (Reuse and Concentration of Sewage by Forward Osmosis Using Fertilizer as Draw Solution)

  • 김승건;이호원
    • 공업화학
    • /
    • 제30권1호
    • /
    • pp.122-131
    • /
    • 2019
  • 본 연구에서는 하수의 재이용과 농축에 비료를 유도용액으로 하는 정삼투 기술을 적용하였다. 1차 침전지 유입수를 30 min간 정치한 상등액(Sewage-1), 1차 침전지 유출수를 30 min간 정치한 상등액(Sewage-2), 1차 침전지 유출수를 $1{\mu}m$ 카트리지 필터에 의해 여과한 여과액(Sewage-3)의 3종류의 하수를 대상으로 하였다. 유도용액은 삼투압, 용해도 및 pH를 고려하여 $NH_4H_2PO_4$, KCl, $KNO_3$, $NH_4Cl$, $(NH_4)_2HPO_4$, $NH_4NO_3$, $NH_4HCO_3$$KHCO_3$의 8종류의 유도용액을 사용하였다. Sewage-3를 대상으로 한 경우의 수투과선속은 하수처리장 방류수의 수투과선속과 거의 유사하였으며, Sewage-1와 Sewage-2의 수투과선속에 비해 크게 나타났다. 비역용질선속은 $NH_4H_2PO_4$가 가장 작았으며, 반대로 $NH_4NO_3$가 가장 크게 나타났다. 본 연구에 사용된 유도용액 중에서 $NH_4H_2PO_4$는 비료의 주요 성분인 질소와 인을 포함하고 있을 뿐 아니라 낮은 비역용질선속을 갖고 있어서 하수의 재이용과 농축에서 가장 유용하게 사용될 수 있을 것으로 판단되었다. $NH_4H_2PO_4$를 유도용액으로 사용한 경우, Sewage-3에 대한 24 h 후의 농축인자는 1.72이었다.

정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구 (A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process)

  • 국영롱;주재영;배윤선;이혜인;정인호;박철휘
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

SWAT모델과 물수지분석을 이용한 물재이용에 의한 도시물순환 변화 분석 (Analysis for water cycle change using SWAT model and water balance analysis depending on water reuse in urban area)

  • 김영란;황성환;이성옥
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.447-457
    • /
    • 2015
  • Water cycle within the human civilization has become important with urbanization. To date, water cycle in the eco-system has been the focus in identifying the degree of water cycle in cities, but in practicality, water cycle within the human civilization system is taking on an increasing importance. While in recent years plans to reuse water have been implemented to restore water cycle in cities, the effect that such reuse has on the entire water cycle system has not been analyzed. The analysis on the effect that water reuse has on urban areas needs to be go beyond measuring the cost-savings and look at the changes brought about in the entire city's water cycle system. This study uses a SWAT model and water balance analysis to review the effects that water reuse has on changes occurring in the urban water cycle system by linking the water cycle within the eco-system with that within the human civilization system. The SWAT model to calculate the components of water cycle in the human civilization system showed that similar to measured data, the daily changes and accumulative data can be simulated. When the amount of water reuse increases in urban areas, the surface outflow, amount of sewer discharge and the discharged amount from sewage treatment plants decrease, leading to a change in water cycle within our human civilization system. The determinant coefficients for reduced surface outflow amount and reduced sewer discharge were 0.9164 and 0.9892, respectively, while the determinant coefficient for reduced discharge of sewage treatment plants was 0.9988. This indicates that with an increase in water reuse, surface flow, sewage and discharge from sewage treatment plants all saw a linear reduction.

Sewage Treatment Using Natural Systems and Effluent Reuse for Crop Irrigation in Small Communities

  • Ham, Jong-Hwa;Yoon, Chun-G.;Jeon, Ji-Hong;Hwang, Ha-Sun
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.70-82
    • /
    • 2003
  • A pilot study was performed from July 1998 to December 2002, including winter performance, to examine seasonal performance of a constructed wetland and subsequent pond system for treatment of sewage in small communities of Korea. Pond was operated as a intermittent-discharge pond during winter period, and continuous flow system during growing season; its effects was evaluated from December 2001 to April 2003. The subsurface flow (SSF) wetland was satisfactory for treating sewage with good removal efficiency even during the winter period. The wetland effluent concentrations of $BOD_5$ and TSS were often higher in winter than in the growing season, but this was explained by the higher loading rates, rather than lower removal efficiency. The relatively poor-quality wetland effluent was further polished during winter in the pond. The upper layer of the pond water column became remarkably clear immediately after ice melt. In the growing season, ponds could be operated as a continuous flow system to remove nutrients and pathogens, and the effluent of pond could be reused as a supplemental irrigation water without risk of infection by sewage-borne pathogens as well as causing adverse effect on growth and yield. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the intermittent-discharge pond was found to be effective for further polishing if necessary. Therefore, the combination of a wetland and subsequent pond system and reuse of effluent as crop irrigation water is recommended as a practical alternative to treat sewage in Korean small communities, and partial discharge of pond water in March is suggested.

하수를 공업용수로 재이용하기 위한 정밀여과 및 역삼투 시스템 적용에 관한 연구 (Application of Microfiltration and Reverse Osmosis System to Sewage Reuse for Industrial Water)

  • 강신경;이해군;김지원
    • 멤브레인
    • /
    • 제12권3호
    • /
    • pp.151-157
    • /
    • 2002
  • 본 연구는 하수를 공업용수로 재이용하기 위한 분리막 시스템 적용에 관한 연구이다. 정밀여과와 역삼투시스템으로 구성된 bench scale 실험장치를 이용하여 하수처리장 현장에서 실험을 수행한 결과, 정밀여과 시스템은 이온성분은 제거할 수 없었으나 SS를 70% 이상 처리할 수 있어 처리수는 직접냉각수로 재이용이 가능하였다. 그리고 역삼투 시스템은 SS는 물론 이온성분도 95% 이상 제거할 수 있어 처리수는 간접냉각수 및 제품세척수로 사용이 가능하였다. $100 m^3$/일 용량의 pilot Plant를 제작하기 위해서는 정밀여과 모듈은 20개, 역삼투 모듈은 12개가 필요하였다.

회전매체를 가진 완전혼합활성슬러지 공법을 이용한 온천지구 하수의 재이용 (Reuse of the sewage from sea area using the Submerged Moving Media Complete Mixing Activated Sludge (SMMCMAS))

  • 김홍태;김학석
    • 한국환경과학회지
    • /
    • 제11권1호
    • /
    • pp.69-74
    • /
    • 2002
  • This study was performed to evaluate an applicability of the SMMCMAS system for reuse of the sewage from spa area and was operated to HLR(Hydraulic loading rate) of 211.3 to 126.8 $\ell$/㎥/d. The operating HRT(Hydraulic retention time) ranges were 2.5 to 1.5 hours. Conclusions are as follows; At the optimum HLR of 158.5 $\ell/\m^2$/d (HRT of 2.0 hours), the maximum BOD removal efficiency was 94% and the effluent BOD concentration was 1.1mg/$\ell$ in result. As the HLR was increased to 211.3 $\ell/\m^2$/d, BOD removal efficiency was decreased to 75% and BOD removal efficiency was also reduced to 74% at lower HLR of 126.8 $\ell/\m^2$/d. It shows that the maximum BOD removal efficiency occurs at an optimum HLR value and that the removal efficiency decreases when the HLR is either higher or lower than the optimum value. Sludge production rates were ranged 0.01 to 0.24gVSS/gBODrem/d and accomplished to 0.01gVSS/gBODrem/d at the optimum HLR of 158.5 $\ell/\m^2$/d.

하수처리수 재이용을 위한 막분리 공정시 응집조건에 따른 투과효율 변화에 관한 연구 (A Study on Flux Efficiency on Membrane for Water Reclamination according to Coagulations)

  • 정진희;장성호;최영익
    • 한국환경과학회지
    • /
    • 제20권6호
    • /
    • pp.767-773
    • /
    • 2011
  • The objectives of this research are to investigate the proper coagulation conditions which are a type and doses of coagulants, mixing conditions (velocity gradients and mixing times), pH and so on through Jar-test, to evaluate the flux variations, permeate, backwashing according to characteristics of pretreatment of the wastewater by means of MF membranes for river maintenance water reuse. The effluent water from B-city K-sewage treatment plant are used for this research. Turbidity and suspended solids(SS) are 14.2 NTU and 10.4 mg/L respectively. This condition causes fouling for membrane process. The flux decline could be reduced when coagulation pretreatment was carried out. Optimal coagulations PAC which are commonly used in the sewage treatment plant was observed in this research. The results indicate that an optimal coagulation dose and pH are 80 ppm and pH of 7 respectively, but coagulation efficiency was lower at strong acid or strong base. Results showed that continuous and steady operations in membrane separation process by means of the effective removal of organic matter and turbidity with coagulation pretreatment of sewage secondary effluent were achieved.