• Title/Summary/Keyword: Sewage Treatment Facility

Search Result 109, Processing Time 0.029 seconds

Relationship Between Environmental Infra Operating Cost and Polluter Pay Principles (환경기초시설 운영비 보조와 오염원인자부담원칙)

  • Kang, Heechan;Kang, Sung Won;Kim, Minjoon
    • Environmental and Resource Economics Review
    • /
    • v.24 no.1
    • /
    • pp.165-187
    • /
    • 2015
  • In this paper, we tested if the sewage subsidy from Korean Water Management Fund discourage sewage fee increase by Korean local governments, and consequently hinder water quality improvement. To examine this counter-incentive effect of Water manage Fund sewage subsidy, we estimated the effect of sewage subsidy on the ratio of sewage fee revenue to environmental treatment facilities' operation cost of local governments in 2009-12, using two-stage least square estimation. We found that the sewage subsidy has negative effect on the sewage fee revenue to sewage operation cost ratio. But, the statistical significance of this effect was sensitive to model specification. And the size was too small to conclude that the counter-incentive effect was economically significant.

Effects of Membrane Filtration Concentrate of Sewage Reuse Facility on Performance of Bioreactor in Sewage Treatment Facility (하수재이용시설 농축수가 하수처리장 생물반응조 운영에 미치는 영향)

  • Lim, Ji-Young;Kim, Hyun-Sik;Bae, Min-Su;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.3
    • /
    • pp.5-14
    • /
    • 2018
  • This study investigated the effect of concentrate of membrane filtration of sewage reuse facilities on bioreactor's microorganisms in sewage treatment facility, and concentrate was analyzed, oxygen uptake rate and continuous activated sludge experiment were performed. As a results, the concentration of organic matter and TP concentration in concentrate was closely related to the concentration of SS and the concentration of ionic substances in concentrate was higher in order of $Cl^-$ > $Na^+$ > $Ca^{2+}$ > $K^+$ > $Mg^{2+}$ > $F^-$. And the analysis value of analytical items was greatly fluctuated according to sampling time of concentrate. Result of OUR test according to the mixing ratio of concentrate to sewage, it was found that the concentrate acts as an organic matter in the activated sludge microorganism and it increases with the increase of the concentrate mixing ratio. As a result of continuous activated sludge experiment, MLSS concentration, organic removal efficiency and TN removal efficiency gradually decreased with increasing concentrate mixing ratio. Based on the experimental results, expected mixing ratio of concentrate to affect the treatment efficiency of activated sludge is 25%.

Bio-oil production using residual sewage sludge after lipid and carbohydrate extraction

  • Supaporn, Pansuwan;Ly, Hoang Vu;Kim, Seung-Soo;Yeom, Sung Ho
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.202-210
    • /
    • 2019
  • In order to maximize the utilization of sewage sludge, a waste from wastewater treatment facility, the residual sewage sludge generated after lipid and carbohydrate extraction for biodiesel and bioethanol production was used to produce bio-oil by pyrolysis. Thermogravimetric analysis showed that sludge pyrolysis mainly occurred between 200 and $550^{\circ}C$ (with peaks formed around 337.0 and $379.3^{\circ}C$) with the decomposition of the main components (carbohydrate, lipid, and protein). Bio-oil was produced using a micro-tubing reactor, and its yield (wt%, g-bio-oil/g-residual sewage sludge) increased with an increase in the reaction temperature and time. The maximum bio-oil yield of 33.3% was obtained after pyrolysis at $390^{\circ}C$ for 5 min, where the largest amount of energy was introduced into the reactor to break the bonds of organic compounds in the sludge. The main components of bio-oil were found to be trans-2-pentenoic acid and 2-methyl-2-pentenoic acid with the highest selectivity of 28.4% and 12.3%, respectively. The kinetic rate constants indicated that the predominant reaction pathway was sewage sludge to bio-oil ($0.1054min^{-1}$), and subsequently to gas ($0.0541min^{-1}$), rather than the direct conversion of sewage sludge to gas ($0.0318min^{-1}$).

Nutrient removal from secondary effluent using filamentous algae in raceway ponds

  • Min, Kyung-Jin;Lee, Jongkeun;Cha, Ho-Young;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • v.10 no.3
    • /
    • pp.191-199
    • /
    • 2019
  • In this study, we investigated the cultivation possibility using Hydrodictyon reticulatum in a continuous raceway pond as a tertiary sewage treatment plant. The cultivation possibility was evaluated by varying the light quantity, wavelength, and hydraulic retention time (HRT). Experimental results showed that the growth rates of algae and the removal efficiencies of nutrients increased as the light quantity increased, and the maximum photosynthetic rate was maintained at $100{\mu}mol/m^2{\cdot}s$ or higher. When wavelength was varied, nutrient removal efficiency and growth rate increased in the following order: green light, red light, white light, and blue light. The nutrient removal efficiencies and algae productivity in HRT 4 d were better than in HRT 8 d. We conclude that if Hydrodictyon reticulatum is cultivated in a raceway pond and used as a tertiary treatment facility in a sewage treatment plant, nutrients can be effectively removed, and production costs can be reduced.

Determination of Interception Flow by Pollution Load Budget Analysis in Combined Sewer Watershed (II) - Establishment of Intercepting Capacity and Reduction Goal of Overflow Pollution Load - (오염부하 물질수지 분석을 통한 합류식 하수관거 적정 차집용량 결정(II) - 차집용량과 월류오염부하 삭감목표 설정 -)

  • Lee, Doojin;Shin, EungBai
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.557-564
    • /
    • 2005
  • The objective of this study is to evaluate a criteria of intercepting capacity and a reduction goal of overflow pollution load in combined sewer system. In the current criteria of intercepting capacity in the domestic sewage facility standard, it is known that three times of peak sewage (Q) in dry period or runoff flow by 2mm/hr is not appropriate since the intercepted flow is estimated by runoff and show different result even in the same watershed. Though a reduction goal of overflow pollution load can be determined from 1) same level of storm-water runoff pollution load in separated storm sewer, 2) less than 5% sewage load in dry weather period, by the domestic sewage facility standard, the simulated results from storm-water model show large differences between two criteria. While it is predicted that sewage pollution load standard three time larger than separated storm sewer standard in high population density and urbanized area, it is shown that separate storm sewer standard larger than sewage pollution load standard in middle population density and developing area. Accordingly, it is proposed that more reasonable intercepting flow and reduction goal of overflows pollution load should be established to minimize discharging pollution load in combined sewer systems. For the purpose, a resonable standard has to be amended by pollution load balance considering the characteristics of a watershed for generation, collection, treatment, and discharging flow.

Optimal Management Scheme for Phosphorus Discharged from Public Sewage Treatment Plant Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 공공 하수종말처리시설의 총인 배출 최적관리)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Jeong, Myungsuk;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.200-209
    • /
    • 2011
  • The purpose of the study is to optimally manage sewage treatment plant with analysis of phosphorus contribution and improvement of water quality contributing rate in the effect of inflowing point of effluent and Pal-Dang lake after reducing T-P discharge from large scale public sewage treatment plant at upstream of Pal-Dang lake. Also, this study, for enforcement of T-P in effluent, plans optimal management of effluent T-P through examining propriety of environmental, technological, and economical aspect such as water quality standard of domestic and foreign T-P and related policy. In regarding optimal management of T-P discharged from public sewage treatment plant located in upstream of Pal-Dang lake, the study drew following conclusions. With the optimal management of public sewage treatment plant, it showed that a pollution level became higher in the order of Sumgang E in South-Han river, C in Dalcheon, B1 B2, A in North-Han river, and J in Kyungancheon, and it is required reduction of T-P first. The highest value in analysis of benefit-costs from sewage treatment plant in the selected research area was Kyungan B, and the others are with the order of Jojong A, Bokha A, Kyungan A, and Yanghwa A. With result of this study, all 14 areas are required more enforced phosphorus treatment. The study resulted that the most top priority areas were Hangang F, Sumgang B, and Gyungan A, top priority areas were Bokha A, Dalcheon B, and Cheongmi A, priority areas were Hangang E, Heukcheon A, Gyungan B, and Jojong A, and potential areas were Sumgang A, Yanghwa A, Dalcheon A, and Hangang D. It seems to be appropriate to apply 0.2 mg/L of T-P treatment for water supply source reservation, 0.5 mg/L for the other areas by locally, and 0.2~0.5 mg/L for biological nitrogen phosphorus treatment method and 0.5~1 mg/L for Conventional Activated Sludge by technologically. Also, it may be appropriate to apply 0.2 mg/L for the most top priority area(I), 0.3 mg/L for the top priority area(II), 0.4 mg/L for priority area(III), and 0.5 mg/L for potential area(IV) by the separation of priority area.

A study on the analysis of performance differences according to the operation method of public sewage treatment facility (공공하수처리시설 운영방식에 따른 성과 차이 분석에 관한 연구)

  • Ko, Hyunsoo;Ha, Donggyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.5
    • /
    • pp.357-370
    • /
    • 2022
  • This study aims to analyze the differences in performance according to various operation methods (direct management, public consignment, and private agency) of public sewage treatment facilities and derive the most efficient and high level of sewage treatment services to the public based on the research results. To this end, economic performance indicators (sewage treatment cost, sewerage rate) and social performance indicators (water quality, number of civil complaints) were selected, and cross-sectional analysis and longitudinal analysis were used to verify the difference between the averages of three or more groups through one-way ANOVA. As a result of the analysis, cross-sectional analysis, there was no difference in economic performance dimension according to the operating method, but in terms of social performance dimension, it was found that there was a difference according to the operating method. In the case of water quality indicators, the results were superior to those directly managed by public consignment and private agencies in the number of civil complaints. In the longitudinal analysis examining the improvement of performance indicators, there was no significant difference by operation method in most performance indicators. In order to improve the efficiency of public services and improve the service level, various approaches suitable for the characteristics of each service are required in addition to the logic of public consignment or introduction of private agency. In the future, when local governments promote public consignment or private agency, it is necessary to understand and promote the nature of the service, the specificity of each local government, and the needs of service users.

Cycling of Matters in the Constructed Wetland (인공습지에서의 물질순환에 관한 연구)

  • Kim, Dong-Oug;Park, Je-Chul
    • Journal of Environmental Science International
    • /
    • v.29 no.3
    • /
    • pp.299-306
    • /
    • 2020
  • This study analyzed the changes in the concentrations of the pollutants of constructed treatment wetlands which come from the discharge water of a sewage treatment plant. According to the results of budgets in constructed wetlands, the net production of the organic carbon, nitrogen and phosphorus were 368 kgC/month, 306 kgN/month and -49 kgP/month, respectively. The high particle form of pollutants are mostly removed due to settlement and absorption when passing through wetlands, but because a low processing efficiency for pollutants was shown when sewage treatment plant wastewater flows in, there is a need for a water management system that can reduce the organic matter load through monitoring. The low removal efficiency of constructed wetlands were caused by both structural and operational problems. Therefore, to enable to play a role as a reduction facility of pollutants, an appropriate design and operation manuals for constructed wetlands is urgently needed.

Feasibility Study on the Construction of Small Hydro-Power Plants in Gumi Sewage Treatment Plant Discharge Point (구미하수처리장 방류구에서의 소수력발전 설치 및 운영에 관한 연구)

  • Nah, Dong-Hun;Lee, Seung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.173-181
    • /
    • 2010
  • This study was conducted to investigate the possible installation of small hydro-power plant at the discharge point of Gumi sewage treatment plant (STP) using treated wastewater. Sufficient amount of water to transfer to electric power and the selection of proper location are two essential elements for the construction of small hydro-power facility. Preliminary analysis based on site visit and existing data in Gumi STP were made. Capacity of the small hydro-power plants and exact location were determined by geomorphological condition and flow duration characteristics. Flow duration characteristics and its duration curve were identified using monthly rainfall data in Gumi STP. Relevant facts of small hydro-power system in other STP were referred to adopt to Gumi STP situation. Flowrate of treated effluents and effective head between flow chamber and the location of hydraulic turbine in Gumi STP are found to be $3.70m^3$/sec and 3.5m respectively. Electric generation rate based on this feasibility study was estimated to be 86.3kW/h. Yearly electric generation rate was expected to be 932.4MMh. Proposed small hydro-power plant construction in Gumi STP is to be reasonable.

Assessment of GHG Reduction Strategy - A Case of Environmental Facilities of Incheon City - (온실가스 감축 전략의 성과평가 - 지자체 환경기초시설 사례 -)

  • Jang, Jong-Ok;Lee, Sung Wook;Kim, Jong Dae
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.509-519
    • /
    • 2017
  • The study focuses on 32 environmental facilities in Incheon Metropolitan City, South Korea, categorizes them by sector: sewage treatment, wastewater treatment, incineration, landfill, water purification, and water supply. Their GHG reduction results are analyzed through quantitative and qualitative measures for 2012 to 2015. The study surveys and examines GHG reductions of the environmental facilities for two categories - facility operation and management. The findings are as follows: First, the GHG reduction rate, an emission-to-allocation ratio, from 2012 to 2015 is 89.67%. Second, GHG reductions coming from qualitative measures of facility management are even greater than those from quantitative measures of facility operation. Third, GHG reductions through facility operation are mostly attributable to overhauls, less use of facilities, resources recycling, process improvement rather than the betterment of fuels, facilities and energy efficiency. Fourth, higher reduction can be achieved by effective facility management, qualitative measures.