• Title/Summary/Keyword: Setting Depth

Search Result 316, Processing Time 0.028 seconds

Development of Universal Graphic User Interface Design for MS Windows for Elderly Users (고령사용자를 위한 MS Windows유니버설 GUI디자인 개발)

  • Kim, Mi-Young;Kim, Hyun-Jeong
    • Archives of design research
    • /
    • v.19 no.1 s.63
    • /
    • pp.15-26
    • /
    • 2006
  • As the interest and use of computer have been increased among elderly users according to the entry to the aging society, the issue of universal design for computer usability was brought forward. Especially, it is widely recognized that universal UI(User Interlace) design on MS windows is important. The objective of this study is to conceptualize Universal GUI design on MS windows which can be used more easily and intuitively by novice users such as elderly and housewives. Especially, the solution for Universal GUI design on MS windows was developed by reflecting elderly users' needs because elderly users is the group with more difficulties than other user groups in learning and using MS windows. First, elderly user's needs was collected by participant observation as a teaching assistant in computer dass for elderly people for 4 weeks. Secondly, the experimental test and in-depth interview was implemented to find difficulties factors and needs in addition to participant observation. Based on the findings, the new GUI design solution was suggested. The design solution consists of ideas in several categories such as setting default, simplification of function for easy conceptual model making, customization of function and working environment, and intuitive GUI in interaction process. The new MS windows GUI design can be accessed by novice mode when user login in window XP. This study has the significance in finding elderly users detailed needs through in-depth and long term participant observation. However, the usability of the suggested prototype needs to be verified to various user groups besides elderly users in the future.

  • PDF

Shape of the model pound net affected by wave and fish behavior to the net - Shape and tension of the model pound net affected by wave - (파동에 의한 모형정치망의 형상변화와 어류대망행동 - 파동에 의한 모형정치망의 형상과 장력변화 -)

  • Lee, Ju-Hee;Kwon, Byeong-Guk;Yun, Il-Bu;Kim, Sam-Kon;Yoo, Je-Bum;Kim, Boo-Young;Kim, Byung-Soo;Lee, Hye-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.2
    • /
    • pp.101-115
    • /
    • 2007
  • The pound net fishery is very important one in Korean coastal fishery and it need to grasp the characteristics of the net affected by many factors. It is considered that the structure and the shape of the pound net can be changed by the direction and speed of current, wave height, depth and conditions of sea bed. However, most of all, the speed of current and wave height influence more upon the pound net than any other factors to deform and flutter. In this study, author carried out the experiments with a model of double one-side pound net made by the similarity law as 1:100 scales at a real experimental area, and additionally the model net experiments were conducted in the circulating water channel in Pukyong National University. The author analyzed the data of transformation of shape and tension of the model pound net to recognize the characteristics of the current and wave acting on it. Regardless of the direction of flow affecting on the fish court net or bag net, the deformed angle and depth to the side panel and bottom of box nets becomes bigger as the wave gets higher and the period of wave is faster. The tension in both upward or downward tends to be changed by the speed of wave. Those value of changes occurred similarly in either fish court net or bag net. Generally, when bag net is located at upward of flow, the value of tension was bigger 10% than any other location or nets. Regardless of the setting direction, the tension of the pound net is increased in proportion to flow speed, wave height and period of wave, and it becomes bigger about 15-30% at upward to flow than downward. Where the flow is upward in the court net, the tension in the wave increased to 37% compared to the one in the flow only in the condition of flow of 0.1-0.3m/s. Where the flow is upward in the bag net, the tension in the wave increased to 52% in the flow of 0.1m/s, and the tension increased to 48% in the flow of 0.2-0.3m/s.

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

Mechanical and Durability Properties of Partial-Depth Patch Materials using Polymer Materials for Concrete Pavement (단면보수용 콘크리트 패치재료의 역학적 특성 및 내구성 실험)

  • Yang, Sung-Chul;Hwang, In-Dong;Han, Seong-Hwan;Kim, Seong-Min
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.23-32
    • /
    • 2009
  • In this paper an experimental program was launched to determine the mechanical and durability properties of spall repair materials (RCC: 3 items, PCC: 2 items, PC: 3 items). Test items were mechanical property tests such as setting times, strengths, modulus of elasticity, plastic shrinkage, and durability tests such as dynamic modulus ratio, bond property with freeze-thaw, water absorption, chemical resistance, ultraviolet exposure. Modulus of the PC products exhibits ductile while the modulus is in the order of RCC > PCC > PC. At early ages the PC products experience higher plastic shrinkage than others, henceforth stable at 28 days. Other test results such as dynamic modulus ratio, absorption, and chemical resistance show that the PCs are superior to the PCCs and the RCCs. Except for PC-2, all patch materials had bond strength more than 1.3MPa after freeze-thaw cycles of 200~300 while the PCs and the PCCs seem to be better than the RCCs. With 500 hours of ultraviolet exposure, all patch materials showed to have no crack or deterioration at the surface.

  • PDF

STUDIES ON THE SHAPE OF FISH REEFS AND THE THRONGING OF FISH SCHOOLS (어초의 형태와 어군의 위집에 관한 연구)

  • SHON Tae Joon;BAE Jeong Sig;SOH Doo Ok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.10 no.3
    • /
    • pp.179-187
    • /
    • 1977
  • This study intended to investigate the shape of the artificial fish reefs settled in the waters of Seogwipo, and the thronging of fish schools into them. The results obtained are summarized as follows : 1. Two types of artifical fish reef, circularized vertical type which is composed of Cryptomeria branches and parachute type, were put off the coast of Seogwipo at $33^{\circ}14'05'$ N Lat., $126^{\circ}34'40'$ E Long. The setting place is located 0.4 sea-mile away from natural fish reefs, at 25 m in depth. And its sediment is consisted of f. S. and Sh. 2. Maximum velocity of wind drift current was 15.28 cm/sec at 15 m depth. The Current direction was $20.5\%$n in the WSW. 3. Maximum fluid resistance of the circularized vertical type to current and wind waves showed about 890 kg, and the weight of sand bags attached to the fish reef totaling 1,200 kg was enough to sustain fish reef. 4. As maximum fluid resistance of the parachute type to current and wind waves was 106.3 kg, the retaining force of sand bags was enough to sustain the fish reef, but vinyl canvas and expansion materials were so poor that the fish reef was lost by the sea current and wind waves. 5. Sixteen species of fish among 53 usually caught in this area were thronged into the artificial fish reef. The fish catches comprized Porgy (Pagrosomus major) $23\%$, black kook fish (Sebastes (Mebarus) intermis) $13\%$, sand borer (Sillago sihama) $11\%$, Sebastes (Pteropodus) hubbsi $7\%$, and file fish (Monacanthus cirrhifer) $6\%$. According to the submarine observations by fivers, it was confirmed that a lot of fish larvae thronged in the middle part of the fish reefs.

  • PDF

Efficacy Evaluation of Anti-wrinkle Products in Japan

  • Masaki Hitoshi
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.29 no.2 s.43
    • /
    • pp.67-77
    • /
    • 2003
  • Two categories of cosmetic products, cosmetics and quasi-drugs, have been established by the Ministry of Health, Labor and Welfare (MHLW) in Japan. Japanese pharmaceutical law has defined that products categorized as cosmetics do not exhibit any effects on human skin. In fact, cosmetic products are not permitted to claim any efficacy. On the other hand, products in the quasi-drug category can claim several efficacies such as anti-inflammatory effects, whitening/lightning effects, hair growth effects and so on. Unfortunately, the Japanese MHLW has not yet approved the efficacy of anti-aging/anti-wrinkle effects as a claim point. However, the population is aging, and the demand for anti-aging/anti-wrinkle products is increasing year by year. Japanese cosmetic companies have proposed to the MHLW that anti-aging/anti-wrinkle agents be approved as a claim concept of a quasi-drug. However, unified evaluation methods for anti-aging/anti-wrinkle effects have not been established. Currently, each company evaluates the efficacy of products/materials using their own original methods. Thus, to request approval of the MHLW, the establishment of a unified evaluation method is needed. Consequently, the Japan Cosmetic Industry Association (JCIA) has established a task force to develop guidelines for evaluating anti-wrinkle effects in 1998. In conclusion, the JCIA would like to adopt visual and image analysis scales to evaluate the anti-wrinkle effects objectively. Generally, wrinkles are roughly classified into three groups as fine wrinkles, linear deep wrinkles and crow's feet. However, academic societies of dermatology or cosmetics have not yet established a definition of wrinkles in Japan. Thus, in advance of setting up an evaluation method, the definition of wrinkles f3r evaluation must be decided. Wrinkles are defined by the task force of the JCIA as follows; furrows that people can recognize visually and that appear on the forehead, the corners of the eyes and the backs of the neck with aging. In addition, furrows are emphasized by exposure to solar light and by dry conditions. Visual evaluation is the most sensitive method and can be applied to most types of wrinkles. However, visual evaluation is hard to express digitally as results. Besides, in the case of image analysis, comparisons of data obtained from distinct examinations can not be done, because data from image analysis are relative values. Thus, to enhance the reliability of the evaluations, the adoption of an objective scale was required. The principle of the evaluation method is to analyze images taken from silicone replicas of wrinkle areas using several parameters, such as the proportion of the wrinkle $area({\%})$, the mean depth of the wrinkles (mm), the mean depth of the deepest wrinkle (m) and the deepest point on the deepest wrinkle. Lights are shown on the skin replica from an orthogonal direction of the main orientation of the wrinkle, and the resulting shadow images are quantified by the image analysis method. To increase the precision of the data or to allow comparisons of independent examinations, a scale with furrows of several depths, 200, 400, 600, 800, and $1000{\mu}m$, is adapted in the evaluation system. I will explain the guidelines established by the JCIA in the presentation.

Evaluation of Tidal Stream Resources Near Uido Using an ADCIRC Model (ADCIRC 모델을 이용한 우이도 주변해역의 조류자원 평가)

  • Jeong, Haechang;Nguyen, Manh Hung;Kim, Bu-Gi;Kim, Jun-Ho;Yang, Changjo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.2
    • /
    • pp.187-193
    • /
    • 2017
  • This study evaluated tidal stream energy resources according to tidal flow properties around Uido off the west coast of, Jeollanam-do, South Korea. A feasibility study was first carried out through the collection of bathymetry data and tidal phase information. For this simulation, a depth-averaged 2D ADCIRC (Advanced Circulation) model for real sea situations was applied to a Finite Element Method (FEM) approach for tides given the variation of tidal current speed. Hydrodynamics were simulated with 4 major tidal constituents (M2, S2, K1, and O1) after setting up 4 observation points. From the real depth-averaged model simulation results, it was found that the spring tide Higher High Water (HHW) and tidal current speed values at the 4 observation points were about 2.2 m and 1.33 m/s, respectively. The ADCIRC model results were analyzed with reference to the Korea Hydrographic and Oceanographic Agency's (KHOA) observed data for verification. Furthermore, using topographical characteristics via the Tidal Flux Method (TFM), tidal energy density distribution was calculated, indicating a maximum tidal energy density of about $1.75kW/m^2$ for the 5 assessment areas around Uido. The tidal energy density was evaluated with consideration given to topographical characteristics as well as tidal elevation and tidal current speed to determine an optimum tidal farm candidate.

Performance assessment of Magnesium Bipolar Plates for Light Weight PEM Fuel Cell (PEM 연료전지 경량화를 위한 마그네슘 분리판의 성능평가)

  • Park, To-Soon;Lee, Dong-Woo;Kim, Kyung-Hwan;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1063-1069
    • /
    • 2012
  • In present paper, we used magnesium alloy having a lower density and higher electrical conductivity for bipolar plate to reduce the weight of PEM fuel cell. The silver was coated to prevent corrosion and form passivation film on the metal surface with sputtering. In acid proof evaluation for setting optimal coating conditions, the homogeneity of coating thickness was improved by coating with the thickness of 3 ${\mu}m$ which not indicated any micro cracks and the temperature $180^{\circ}C$. The performance test and evaluation based on the clamping pressure and channel depth to determine the configuration of bipolar plate for assembling single cell was implemented. And then we assembled single cell with this bipolar plate and implemented the performance test to ensure and compare the current-voltage performance followed as several factors such as coating or non-coating, the change of clamping pressure, the change of channel depth, etc. As these results, the maximum power density of single cell with the coated bipolar plate was 192 $mW/cm^2$ and it was confirmed that the power density per unit mass was better than existing metal bipolar plate.

The Fundamental Properties of Foamed Concrete as the Eco-friendly Ground Repair System for Cast in Site Using the CSA (CSA를 사용한 친환경 지반보수용 현장 기포콘크리트의 기초 특성 검토)

  • Woo, Yang-Yi;Park, Keun-Bae;Ma, Young;Song, Hun-Young
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.53-61
    • /
    • 2020
  • This study aimed to develop a foam concrete material for a ground repair system that has low strength and low fluidity by using an eco-friendly binder, which substitutes industrial by-products for more than 90% of cement. Basic properties were evaluated after substituting a small amount of calcium sulfo aluminate (CSA) for the binder to improve the sinking depth rate and volume change, commonly found when it had a large amount of industrial by-products. The substitution rates of CSA for the eco-friendly binder used for the foam concrete were 2.5, 5, and 10%. Fresh properties, hardened properties, pore structure, and hydrates were analyzed. Experimental results showed that using only 2.5% of CSA could improve the deep sinking depth which occurred when using an eco-friendly binder. As a result, the weight difference between the upper, middle, and lower parts of cast specimens was improved even after being hardened. The addition of CSA also contributed to the formation of small, uniformly sized closed pores and improved initial strength. However, when the proportion of CSA increased, the long-term strength decreased. However, it satisfied the target strength when 5% or less of CSA was used. The results of this study revealed that it was possible to manufacture foam concrete with low strength and high fluidity for repairing ground satisfying target qualities by adding 2.5% of CSA to the eco-friendly binder containing a large amount of industrial by-products.

An Experimental Study on the Development and Possible Solution of Thermal Runaway Model of Electronic Moxibustion with System Error (전자뜸의 시스템 오류에 의한 열폭주 모델 구현 및 해결 방법에 관한 실험적 연구)

  • Lee, Byung Wook;Oh, Yong Taek;Jang, Hansol;Choi, Seong-Kyeong;Jo, Hyo Rim;Sung, Won-Suk;Kim, Eun-Jung
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.282-289
    • /
    • 2021
  • Objectives : The purpose of this study is to construct a model of the possible thermal runaway of electronic moxibustion and to implement an appropriate risk management method. Methods : To reproduce the system error situation of the electronic moxibustion circuit equipped with microcontroller unit, temperature sensor and heater, a code was set to disable the signal input to temperature sensor and maintain "high" heating signal to heater. The temperature change of electronic moxibustion was compared between 3 types of heater module; module 1 consisting of a combination of heater+0 ohm+0 ohm resistance, module 2 consisting of a combination of heater+Polymeric Positive Temperature Coefficient (PPTC)+0 ohm resistance, and module 3 consisting of a combination of heater+PPTC+10 ohm resistance. The temperature change was measured using a polydimethylsiloxane (PDMS) silicone phantom. After maintaining surface temperature of the phantom at 31~32℃ for 20 seconds, electronic moxibustion was applied. After operating electronic moxibustion, the temperature change was measured for 660 seconds on the surface and 900 seconds at 2 mm depth. Results : Regardless of the module type, the time-dependent change in temperature showed a rapid rise followed by a gentle curve, and a sharp drop in temperature after reaching the maximum temperature about 10 minutes after the switching the moxibustion on. Temperature measured at the depth of 2 mm below the surface increased slower and to a lesser extent. Module 1 reached highest peak temperature with largest change of temperature at both depths followed by module 2, and 3. Conclusions : Through the combination of PPTC+resistance with the heater of electronic moxibustion, it is possible to limit the rise in temperature even with the software error. Thus, this setting can be used as an independent safety measure for the electronic moxibustion control unit.