• Title/Summary/Keyword: Set-point Temperature

Search Result 205, Processing Time 0.028 seconds

Highly filled AIN/epoxy composites for microelectronic encapsulation (반도체 봉지용 고충진 AIN/Epoxy 복합재료)

  • 배종우;김원호;황영훈
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.131-134
    • /
    • 2000
  • Increased temperature adversely affects the reliability of a device. So, package material should have high thermal diffusion, i.e., high thermal conductivity. And, there are several other physical properties of polymeric materials that are important to microelectronics packaging, some of which are a low dielectric constant, a low coefficient of thermal expansion (CTE), and a high flexural strength. In this study, to get practical maximum packing fraction of AIN (granular type) filled EMC, the properties such as the spiral flow, thermal conductivity, CTE, and water resistance of AIN-filled EMC (65-vol%) were evaluated according to the size of AIN and the filler-size distribution. Also, physical properties of AIN filled EMC above 65-vol% were evaluated according to increasing AIN content at the point of maximum packing fraction (highly loading condition). The high loading conditions of EMC were set $D_L/D_S$=12 and $X_S$=0.25 like as filler of sphere shape and the AIN filled EMC in this conditions can be obtained satisfactory fluidity up to 70-vol%. As a result, the AIN filled EMC (70-vol%) at high loading condition showed improved thermal conductivity (about 6 W/m-K), dielectric constant (2.0~3.0), CTE(less than 14 ppm/$^{\circ}C$) and water resistance. So, the AIN filled EMC (70-vol%) at high loading condition meets the requirement fur advanced microelectronic packaging materials.

  • PDF

Development of a Salt Taste Sensor for Improvement on Meal HabitDirection Method (식습관 개선을 위한 음식 짠맛센서 개발)

  • Yang, Gil-Mo;Seo, In-Ho;Kim, Gi-Young;Lee, Kang-Jin;Son, Jae-Yong;Mo, Chang-Yeon;Kim, Yong-Hoon;Park, Saet-Byoul
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.310-315
    • /
    • 2010
  • The amount of salt intake of Korean people is 11.4 grams per a day, which is 2.3 times of the recommended daily salt intake by WHO - 5 grams of salt a day. The relationship between high salt consumption and increased risk of high blood pressure, observed not only in hypertensive but also in normotensive patients. High salt intake is also associated with an increased risk of heart attack, cerebral ischemia and osteoporosis. Therefore, this research is for developing a salt taste sensor to reduce sodium consumption and improve meal habits for the perception of a more bland taste of most foods. When the sensor was put into food sample, current intensity achieved with distribution cables. Current intensity was correlate with a simple equivalent of salt taste stimulus intensity. The salt taste sensor consists of salinity & temperature measuring probe, signal processing circuit and LCD display & LED warning light. When salinity is going over a set point, LCD displayer indicate salt taste on LCD panel by percent value (%), and at the same time, blue LED light change to red LED light. So we could know the grade of salt taste in soup before meals conveniently and objectively. The results show that operating range of 10 to $80^{\circ}C$ and accuracy of ${\pm}0.1%$ were achieved with an analysis time of about 2 or 3 sec. Moderate reductions in salt intake can help to avert adult diseases and lead a healthy life.

Development of Control Method for Air-Conditioner as the Resources of DLC (직접부하제어자원으로서 에어컨 주기제어 방법론 개발)

  • Doo, Seog-Bae;Kim, Jeoung-Uk;Kim, Hyeong-Jung;Kim, Hoi-Cheol;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.145-147
    • /
    • 2005
  • This paper presents a methodology for satisfying the thermal comfort of Indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. KEPCO(Korea Electric Power Corporation) use the fixed duty cycle control method regardless of the indoor thermal environment. This method has disadvantages that energy saying depends on the set-point value of the Air-Conditioner and DLC has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. A variable duty cycle estimates the PMV(Predict Mean Vote) at the next step with a predicted temperature and humidity coming from the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. The proposed methodology uses the historical real data of Sep. 7th, 2001 from a classroom in seoul to verify the effectiveness of the variable duty cycle method comparing with fixed duty cycle. The result shows that the variable duty cycle reduces the peak demand to 2.6times more than fixed duty cycle and increases the load control ratio by 8% more. Based on the variable duty cycle control algorithm, the effectiveness of DLC is much more improved as compared with the fixed duty cycle.

  • PDF

Pointing Accuracy Establishment and Efficiency Measurement of 13.7m Antenna for Observing Cosmic Radio Wave (13.7m 우주전파 관측용 안테나의 지향정도 확립과 효율 측정)

  • Cho, Se-Hyung;Jung, Jae-Hoon;Lee, Young-Ung;Kim, Hyun-Goo;Roh, Duk-Gyoo;Park, Yong-Sun;Kim, Bong-Gyu;Auh, Byung-Ryul;Lee, Chang-Hoon;Yim, In-Sung
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.18-28
    • /
    • 1989
  • In this paper, we describe a pointing accuracy establishment and efficiency measurement of 13.7 m antenna for observing cosmic radio wave which is in the first stage just after finishing its installation. The initial stage of pointing model, 1 and 2 were set up with the observational data of Sun and Moon which are large in visual diameter and also strong in radio intensity. Based on this model, model 3 and 4 were established within the available operational range, i.e., 3.8" in azimuth deviation, 10.5" in elevation deviation, with the observational data of SiO maser source which is a point source and distributed in overall sky. Both apeture efficiency anhd beam efficiency were measured by observing Venus whose brightness temperature is well-known. The resulting corrected efficiencies were 35% and 50% respectively.

  • PDF

The Case Analysis through Fire Simulation FDS and Evacuation Simulation Pathfinder (화재 시뮬레이션 FDS와 피난시뮬레이션 Pathfinder 사례분석)

  • Kim, Jong Yoon;Jeon, Yong Han
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.6
    • /
    • pp.253-260
    • /
    • 2015
  • In this study, using the FDS as the fire simulation and evacuation simulations of the Pathfinder, set the main control room of the building to the fire point fire safety assessment studies were carried out. At first the quantitative result such as distribution of visibility as time passing, distribution of temperature, distribution of CO density produced results using fire-simulation and evacuation-simulation was carried out based on the result that produced the final safety evaluation result as being calculated of evacuation time. As the risk increased with the distribution of visibility at the result of fire-simulation, evacuation-simulation was carried out using the result. Finally the result was made 127.9 sec that everyone could evacuate. The numerical results are analyzed in case of the places in the building required safe egress time for safety a as the analysis to be no more than available safe egress time was analyzed to be secured. The results of this safety evaluation represent that more smooth evacuation safety performance can be secured by linking the event of fire firefighting equipment as a result of simulating the worst conditions.

  • PDF

DNA Extraction from Protozoan Oocysts/Cysts in Feces for Diagnostic PCR

  • Hawash, Yousry
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.3
    • /
    • pp.263-271
    • /
    • 2014
  • PCR detection of intestinal protozoa is often restrained by a poor DNA recovery or by inhibitors present in feces. The need for an extraction protocol that can overcome these obstacles is therefore clear. $QIAamp^{(R)}$ DNA Stool Mini Kit (Qiagen) was evaluated for its ability to recover DNA from oocysts/cysts directly from feces. Twenty-five Giardia-positive, 15 Cryptosporidium-positive, 15 Entamoeba histolytica-positive, and 45 protozoa-free samples were processed as control by microscopy and immunoassay tests. DNA extracts were amplified using 3 sets of published primers. Following the manufacturer's protocol, the kit showed sensitivity and specificity of 100% towards Giardia and Entamoeba. However, for Cryptosporidium, the sensitivity and specificity were 60% (9/15) and 100%, respectively. A series of optimization experiments involving various steps of the kit's protocol were conducted using Cryptosporidium-positive samples. The best DNA recoveries were gained by raising the lysis temperature to the boiling point for 10 min and the incubation time of the InhibitEX tablet to 5 min. Also, using a pre-cooled ethanol for nucleic acid precipitation and small elution volume ($50-100{\mu}l$) were valuable. The sensitivity of the amended protocol to Cryptosporidium was raised to 100%. Cryptosporidium DNA was successfully amplified by either the first or the second primer set. When applied on parasite-free feces spiked with variable oocysts/cysts counts, ${\approx}2$ oocysts/cysts were theoretically enough for detection by PCR. To conclude, the Qiagen kit with the amended protocol was proved to be suitable for protozoan DNA extraction directly from feces and support PCR diagnosis.

Design Study of A Spent Fuel Shipping Cask for Korea Nuclear Unit-1 (고리 1호기의 기사용 핵연료 집합체 수송용기 설계에 관한 연구)

  • Moo Han Kim;Chang Sun Kang
    • Nuclear Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.196-203
    • /
    • 1982
  • To transport the spent fuel assemblies of Korea Nuclear Unit 1, which is a Westinghouse type two loop pressurized water reactor, it has been found that steel is the most appropriate material for the design of a shipping cask in comparison with lead and depleted uranium. The proposed shipping cask will transport nine fuel assemblies at the same time and is well within the weight limit of transportation by unrestricted rail car. The cask requires 33cm thick steel shield and 27cm thick water region to satisfy the 3 feet apart dose rate limit set forth in 10 CFR 71, and 1.27cm thick steel boron fuel basket to hold the fuel elements inside the cask and control the effective multiplication factor. As a safety analysis, the fuel cladding and centerline temperatures were calculated under the accident condition of complete loss of water coolant, and it was found that the temperature was much lower than the limit of the melting point. k$_{eff}$ was calculated with fresh fuel assemblies, which was found to be well lower than 0.95. For shielding computation, the multipurpose Monte Carlo code MORSE-CG and one dimensional discrete ordinates transport code ANISN were used, and the Monte Carlo codes KENO and MORSE-CG were used for criticality calculation. The radiation source terms were calculated using ORIGEN-79.9.

  • PDF

Instability and Transition of Nonparallel Bouyancy-Induced Flows Adjacent to an Ice Surface Melting in Water (얼음 벽면의 융해율을 고려한 비평행 자연대류에서 유동의 불안정성과 천이에 관한 연구)

  • Hwang, Y.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.437-450
    • /
    • 1996
  • A set of stability equations is formulated for natural convection flows adjacent to a vertical isothermal surface melting in cold pure water. It takes account of the nonparallelism of the base flows. The melting rate is regarded as a blowing velocity at the ice surface. The numerical solutions of the linear stability equations which constitute a two-point boundary value problem are accurately obtained for various values of the density extremum parameter $R=(T_m-T_{\infty})/(T_0-T_{\infty})$ in the range $0.3{\leq}R{\leq}0.6$, by using a computer code COLNEW. The blowing effects on the base flow becomes more significant as ambient temperature ($T_{\infty}$) increases to $T_{\infty}=10^{\circ}C$. The maximum decrease of heat transfer rate is about 6.4 percent. The stability results show that the melting at surface causes the critical Grashof number $G^*$ and the maximum frequency of disturbances to decrease. In comparision with the results for the conventional parallel flow model, the nonparallel flow model has a higher critical Grashof number but has lower amplification rates of disturbances than does the parallel flow model. The spatial amplification contours exhibit that the selective frequency $B_0$ of the nonparallel flow model is higher than that of the parallel flow model and that the effects of melting are rather small. The present study also indicates that the selective frequency $B_0$ can be easily predicted by the value of the frequency parameter $B^*$ at $G^*$, which comes from the neutral stability results of the nonparallel flow model.

  • PDF

Study on the Characteristics of Scroll type Stirling Engine Receiver for Solar Thermal Power (태양열 발전용 스크롤 방식 스터링엔진 흡수기 특성 연구)

  • Seo, Ho-Young;Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.62-67
    • /
    • 2009
  • This paper describes the characteristics of scroll type stirling engine receiver. Scroll type stirling engine operated scroll compressor and expander instead of piston. Pass dimension of the receiver was $14(W){\times}14(H)$ mm and total pass length was 5,049 mm. External dimension of the receiver was $300{\times}300mm$. The experimental facility consisted of parabolic dish concentrator, compressor to supply air, triplex air filter, and flowmeter. In this study, basic experimental conditions were set at a inlet pressure of 5 bar and volume flow rate of $25m^3/hr$. As a result, air temperature in receiver at each measuring position of point 1, 2, 3 were $241^{\circ}C$, $465^{\circ}C$, and $542^{\circ}C$ respectively at inlet pressure of 5.5 bar and volume flow rate of $24.6m^3/hr$. As DNI increasing, heat transfer coefficient of the receiver changed from $695W/m^2K$ to $827W/m^2K$. Average heat transfer coefficient of receiver in the experiment was $798W/m^2K$. In addition, receiver efficiency became about 83%.

  • PDF

Heating and Cooling Energy Demand Analysis of Standard Rural House Models (농어촌 주택 표준모델의 냉난방에너지요구량 분석)

  • Lee, Chan-Kyu;Kim, Woo-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3307-3314
    • /
    • 2012
  • The annual energy demand of the standard rural house models was analyzed using the DesignBuilder. Indoor temperature set-point, U-value of outer wall, type of window, and degree of ventilation were selected as simulation parameters. In all the simulation cases, heating energy demand was higher than cooling energy demand regardless of the building size. When the lower U-value of the outer wall was applied to account for the thicker insulation layer, heating energy demand was decreased while cooling energy demand was increased. However, it is better to reduce the area of outer wall which is directly exposed to outdoor air because reducing the U-value of the outer wall is not effective in decreasing heating energy demand. Among the four different window types, the double skin window is most favorable because heating energy demand is the lowest. For a fixed infiltration rate, higher ventilation rate resulted in an increased heating energy demand and had minor impact on cooling energy demand. As long as the indoor air quality is acceptable, lower ventilation rate is favorable to reduce the annual energy demand.