• 제목/요약/키워드: Set pressure

검색결과 1,337건 처리시간 0.026초

소화기관내의 압력 모니터링 시스템 (Pressure Monitoring System in Gastro-Intestinal Track)

  • 김용인;박석호;김병규;박종오
    • 제어로봇시스템학회논문지
    • /
    • 제10권11호
    • /
    • pp.1089-1094
    • /
    • 2004
  • Diseases in the gastro-intestinal track are on an increasing trend. In order to diagnose a patient, the various signals of the digestive organ, such as temperature, pH, and pressure, can offer the helpful information. Among the above mentioned signals, we choose the pressure variation as a monitoring signal. The variation of a pressure signal of the gastro-intestinal track can offer the information of a digestive trouble or some clues of the diseases. In this paper, a pressure monitoring system for the digestive organs of a living pig is presented. This system concept is to transmit the measured biomedical signals from a transmitter in a living pig to wireless receiver that is positioned out of body. The integrated solution includes the following parts: (1) the swallow type pressure capsule, (2) the receiving set consisting of a receiver, decoder box, and PC. The merit of the proposed system if that the monitoring system can supply the precise and repeatable pressure in the gastro-intestinal track. In addition, the design of low power consumption enables it to keep sending reliable signals while the pressure capsule is working in the digestive organ. The subject of the study for the pressure monitoring system is in-vivo experiments for a living pig. We achieved the pressure tracings in digestive organs and verified the validity of system after several in-vivo tests using pressure monitoring system. As a result, we found each organ has its own characterized pressure fluctuation.

쌍곡선포물선 대공간 구조물의 측벽개구율에 따른 지붕의 풍압특성 (Characteristic of Wind Pressure Distribution on the Roof of Hyperbolic Paraboloid Spatial Structures)

  • 유장열;유기표
    • 한국공간구조학회논문집
    • /
    • 제13권1호
    • /
    • pp.51-57
    • /
    • 2013
  • There can be diverse causes in the destruction of a large space structure by strong wind such as characteristics of construction materials and changes in internal and external wind pressure of the structure. To evaluate the wind pressure of roof against the large space structure, wind pressure experiment is performed. However, in this wind pressure experiment, peak internal pressure coefficient is set according to the opening of the roof in Korea wind code. In this article, it was tried to identify the change of internal pressure coefficient and the characteristics of wind pressure coefficient acting on the roof by two kinds of opening on the side of the structure with Hyperbolic Paraboloid Spatial Structures roof. When analyzing internal pressure coefficient according to roof shape, it was found that minimum (52%) and maximum (30%~80%) overestimation was made comparing to partial opening type proposed in the current wind load. It is judged that evaluation according to the opening rate of the structure should be made to evaluate the internal pressure coefficient according to load.

음향집어기의 집어 효과 (Effects an Acoustical Equipment on the Luring of Fish School)

  • 장선덕
    • 수산해양기술연구
    • /
    • 제22권4호
    • /
    • pp.75-82
    • /
    • 1986
  • 음향집어에 관한 기초자료를 제공하기 위하여 정치망내의 수중환경소음과 방성음의 분포 및 집어효과를 실험, 분석하였고, 그 결과를 요약하면 다음과 같다. 1. 수중환경 소음 및 방성음의 중심주파수대는 각각 150Hz~400Hz, 400Hz~1000Hz이고, 음압준위는 원통, 헛통, 장등, 비탈그물의 순으로 , 비탈그물, 원통, 헛통, 장등의 순으로 각각 높았다. 양망작업중의 수중소음은 양망개시후 시간의 경과에 따라 음압준위가 높아지나 양망의 마무리 단계에서는 오히려 낮아졌다. 2. 본 실험에서 제작한 방성장치로서 정치망어포부내에 방성한 결과, 초기에는 어군이 방성기주변으로 모여드는 반응을 나타내었으나, 약 30분이 경과하면서 이러한 반응은 약화되었다. 그리고 방성시간과 휴지시간의 간격보다는 방성음압에 군락이 더 민감하였다. 3. 일본에서 제작된 음향집어기(Dainy 0-8)로 해상에서 방성시험을 하여 본 결과, 대체로 방성개시후 약 20분에 어군이 모여들고 방성을 멈추면 곧 흩어졌다. 유집된 어군은 선박교통소음의 환경을 많이 받는 것으로 나타났다. 정치망입구 근처의 장등에 음향집어기를 설치하여 방성하였을 경우와 방성하지 않았을 경우에 대한 어획량이 방성하지 않았을 때에 비하여 약 3~5배 많은 것으로 나타났다.

  • PDF

건식식각 기술 이용한 실리콘 압력센서의 특성 (Characteristics silicon pressure sensor using dry etching technology)

  • 우동균;이경일;김흥락;서호철;이영태
    • 센서학회지
    • /
    • 제19권2호
    • /
    • pp.137-141
    • /
    • 2010
  • In this paper, we fabricated silicon piezoresistive pressure sensor with dry etching technology which used Deep-RIE and etching delay technology which used SOI(silicon-on-insulator) wafer. We improved pressure sensor offset and its temperature dependence by removing oxidation layer of SOI wafer which was used for dry etching delay layer. Sensitivity of the fabricated pressure sensor was about 0.56 mV/V${\cdot}$kPa at 10 kPa full-scale, and nonlinearity of the fabricated pressure sensor was less than 2 %F.S. The zero off-set change rate was less than 0.6 %F.S.

CMP 후 세정용 PVA 브러쉬의 접촉압력 분포 측정 (Contact Pressure Distribution Measurement of PVA Brush for Post CMP Cleaning)

  • 유선중;김덕중
    • 반도체디스플레이기술학회지
    • /
    • 제15권4호
    • /
    • pp.73-78
    • /
    • 2016
  • Contact pressure distribution between PVA brush and semiconductor wafer was measured by developing a test setup which could simulates the post CMP cleaning process. The test set-up used thin film type pressure sensor which could measure the pressure distribution of contact area with the resolution of $15.5ea/cm^2$. As the experimental results, it was verified that there had been severe contact pressure non-uniformity along the axis of the brush and between the adjacent projections on the brush's surface. These results should be considered when developing post CMP cleaning stage or designing the PVA brush.

Fluid Infiltration Effect on Breakdown Pressure in Laboratory Hydraulic Fracturing Tests

  • Diaz, Melvin B.;Jung, Sung Gyu;Lee, Gyung Won;Kim, Kwang Yeom
    • 지질공학
    • /
    • 제32권3호
    • /
    • pp.389-399
    • /
    • 2022
  • Observations on the influence of the fluid infiltration on the breakdown pressure during laboratory hydraulic fracturing tests, along with an analysis of the applicability of the breakdown pressure prediction for cylindrical samples using Quasi-static and Linear Elastic Fracture Mechanics approaches were carried out. These approaches consider fluid infiltration through the so-called radius of fluid infiltration or crack radius, a parameter that is not a material property. Two sets of tests under pressurization rate controlled and injection rate controlled tests were used to evaluate the applicability of these methods. The difficulty of the estimation of the radius of fluid infiltration was solved by back calculating this parameter from an initial set of tests, and later, the obtained relationships were used to predict breakdown pressures for a second set of tests. The results showed better predictions for the injection rate than for the pressurization rate tests, with average errors of 3.4% and 18.6%, respectively. The larger error was attributed to differences in the testing conditions for the pressurization rate tests, which had different applied vertical pressures. On the other hand, for the tests carried out under constant injection rate, the Linear Elastic Fracture Mechanics solution reported lower errors compared to the Quasi-static solution, with values of 3% and 3.8%, respectively. Moreover, a sensitivity analysis illustrated the influence of the radius of fluid penetration or crack radius and the tensile strength on the breakdown pressure, suggesting a need for a careful estimation of these values. Then, the calculation of breakdown pressure considering fluid infiltration in cylindrical samples under triaxial conditions is possible, although larger data sets are desirable to validate and derive better relations.

Pressure Monitoring System in Gastro-Intestinal Tract

  • Kim, Byung-Kyu;Kim, Yong-In;Park, Suk-Ho;Jo, Jin-Ho;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.196-201
    • /
    • 2005
  • Diseases in the gastro-intestinal tract are on an increasing trend. In order to diagnose a patient, various signals of the digestive organ, such as temperature, pH, and pressure, can offer the helpful information. Among the above mentioned signals, we choose the pressure variation as a monitoring signal. The variation of a pressure signal of the gastro-intestinal tract can offer the information of a digestive trouble or some clues of the diseases. In this paper, a pressure monitoring system for the digestive organs of a living pig is presented. This is why a pig's gastro-intestinal tract is very similar as human's. This system concept is to transmit the measured biomedical signals from a transmitter in a living pig to a wireless receiver that is positioned out of body. The integrated solution includes the swallow type pressure capsule and the receiving set consisting of a receiver, decoder circuit. The merit of the proposed system is that the monitoring system can supply the precise and a durable characteristic to measure and to transmit a signal in the gastro-intestinal tract. We achieved the pressure tracings in digestive organs and verified the validity of system after several in-vivo tests using the pressure monitoring system. Through various experiments, we found each organ has its own characterized pressure fluctuation.

  • PDF

A Pressure Adjustment Protocol for Programmable Valves

  • Kim, Kyoung-Hun;Yeo, In-Seoung;Yi, Jin-Seok;Lee, Hyung-Jin;Yang, Ji-Ho;Lee, Il-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.370-377
    • /
    • 2009
  • Objective : There is no definite adjustment protocol for patients shunted with programmable valves. Therefore, we attempted to find an appropriate method to adjust the valve, initial valve-opening pressure, adjustment scale, adjustment time interval, and final valve-opening pressure of a programmable valve. Methods : Seventy patients with hydrocephalus of various etiologies were shunted with programmable shunting devices (Micro Valve with $RICKHAM^{(R)}$ Reservoir). The most common initial diseases were subarachnoid hemorrhage (SAH) and head trauma. Sixty-six patients had a communicating type of hydrocephalus, and 4 had an obstructive type of hydrocephalus. Fifty-one patients had normal pressure-type hydrocephalus and 19 patients had high pressure-type hydrocephalus. We set the initial valve pressure to $10-30\;mmH_2O$, which is lower than the preoperative lumbar tapping pressure or the intraoperative ventricular tapping pressure, conducted brain computerized tomographic (CT) scans every 2 to 3 weeks, correlated results with clinical symptoms, and reset valve-opening pressures. Results : Initial valve-opening pressures varied from 30 to $180\;mmH_2O$ (mean, $102{\pm}27.5\;mmH_2O$). In high pressure-type hydrocephalus patients, we have set the initial valve-opening pressure from 100 to $180\;mmH_2O$. We decreased the valve-opening pressure $20-30\;mmH_2O$ at every 2- or 3-week interval, until hydrocephalus-related symptoms improved and the size of the ventricle was normalized. There were 154 adjustments in 81 operations (mean, 1.9 times). In 19 high pressure-type patients, final valve-opening pressures were $30-160\;mmH_2O$, and 16 (84%) patients' symptoms had nearly improved completely. However, in 51 normal pressure-type patients, only 31 (61%) had improved. Surprisingly, in 22 of the 31 normal pressure-type improved patients, final valve-opening pressures were $30\;mmH_2O$ (16 patients) and $40\;mmH_2O$ (6 patients). Furthermore, when final valve-opening pressures were adjusted to $30\;mmH_2O$, 14 patients symptom was improved just at the point. There were 18 (22%) major complications : 7 subdural hygroma, 6 shunt obstructions, and 5 shunt infections. Conclusion : In normal pressure-type hydrocephalus, most patients improved when the final valve-opening pressure was $30\;mmH_2O$. We suggest that all normal pressure-type hydrocephalus patients be shunted with programmable valves, and their initial valve-opening pressures set to $10-30\;mmH_2O$ below their preoperative cerebrospinal fluid (CSF) pressures. If final valve-opening pressures are lowered in 20 or $30\;mmH_2O$ scale at 2- or 3-week intervals, reaching a final pressure of $30\;mmH_2O$, we believe that there is a low risk of overdrainage syndromes.

은 잉크를 이용한 그라비아 오프셋의 전극인쇄에서 닥터링 공정의 영향 (The Effects of Doctoring Process in Gravure Off-set Printing on Patterning of Electrodes with Ag Ink)

  • 최기성;박진석;송정근
    • 한국전기전자재료학회논문지
    • /
    • 제26권6호
    • /
    • pp.462-467
    • /
    • 2013
  • In this paper, we analyzed the effects of doctoring process on the patterns of Ag ink in gravure off-set printing. The parameters of doctoring process were the angle and the pressure, which was represented by the depth of blade movement to the gravure roll, of doctor blade to the surface of gravure roll, and the angle of patterns engraved on the gravure roll to the doctor blade moving direction. The proper parameters were extracted for the fine patterns and they were 15 mm for the pressure, $60^{\circ}$ for the blade angle. And the angle of patterns with respect to the blade movement should be less than $40^{\circ}$ for the best results. The gravure off-set printing with the above parameters was carried out to print gate electrodes and scan bus lines of OTFT-backplane for e-paper. The line width of $50{\mu}m$ was successfully obtained. The thickness of electrodes was $2.5{\mu}m$ and the surface roughness was $0.65{\mu}m$ and the sheet resistance was $15.8{\Omega}/{\Box}$.

자유수면의 모의를 위한 레블셑V 기법의 적용 (Application of the Level Set Method for Free Surface Modeling)

  • 이해균
    • 한국콘텐츠학회논문지
    • /
    • 제10권10호
    • /
    • pp.451-455
    • /
    • 2010
  • 수리학에서 다루는 유체 현상은 물과 공기의 경계면인 자유수면을 포함할 때가 많다. 수표면의 곡률이 작은 경우에는 정수압 가정이 적절하지만, 그렇지 않은 경우에는 비정수압 분포를 고려하여야 한다. 이와 같은 문제에서는 수심적분된 천수방정식이 아닌, 네비어-스토크스 방정식(Navier-Stokes equations)에 의존해야 할 때가 많다. 특성이 다른 두 유체, 예를 들면, 물과 공기, 물과 기름과 같이 섞이지 않는 두 유체의 모의를 위하여 본 연구에서는 널리 알려진 레블셑V 기법을, 고전적인 문제인 댐 파괴 문제의 모의에 적용하여 이를 실험결과, 기존 수치모델링 결과와 비교하고 효용성을 확인하였다.