• Title/Summary/Keyword: Set pressure

Search Result 1,337, Processing Time 0.027 seconds

A Study on Fatigue Wear Improvement of High Pressure Seal for Tracked Vehicle Suspension (궤도차량 현수장치 고압용 시일의 피로마모 개선 연구)

  • Lee, Yongjun;Kim, Hyeonghyeon;Kim, Kyungro;Koo, Yungseo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.12-17
    • /
    • 2017
  • In this paper, causes of wear on high pressure seals for suspension are analyzed, and the result of reproduction test and verification on improved design are described. First, by performing the observation of worn surfaces and its failure analysis, the primary cause of wear on the seals are analyzed. The result of analysis shows that the main failure mechanism of wear is a fatigue wear, and test criteria for failure reproduction are set up with consideration for frequency condition, surface roughness and pressure. Durability comparison test on the condition of low amplitude and high frequency is carried out. And, it is found that the durability of wear on seals by increasing hardness of cylinder and managing for surface roughness is enhanced.

A Study of Variation of Wave-induced Stresses in a Seabed (파랑하중에 의한 해저지반의 응력변화에 대한 연구)

  • 장병욱;박영권;우철웅
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.1
    • /
    • pp.79-89
    • /
    • 1996
  • It is expected that the soil hehaviours in the seahed subjected to cyclic wave loads are much different from that on the ground Cyclic shear stresses developed below the ocean bed as a result of a passing wave train may progressively build up pore pressure in certain soils. Such build-up pore pressure may be developed dynamic behaviour such as liquefaction and significant deformation of the seabed. Currently available analytical and testing methods for the seabed subjected to cyclic wave loads are not general. The purpose of the study are to provide a test method in laboratory and to analyse the mechanism of wave-induced stresses and liquefactions potentials of the unsaturated silty marine sand. It is showed that the test set-up made especially for this study delivers exactly oscillatory wave pressures of the form of sine function. Laboratory test results defining the cyclic shear strength of the unsaturated porous medium that is homogenously sedimented. It is understood that the pore water pressure due to induced-waves is not accumulated as the wave number increases but reveals periodical change on the still water surface. The magnitude of the pore water pressure tends to be attenuated radically with a certain time lag under the action of both high and low waves as depth increases.

  • PDF

Seismic responses of a metro tunnel in a ground fissure site

  • Liu, Nina;Huang, Qiang-Bing;Fan, Wen;Ma, Yu-Jie;Peng, Jian-Bing
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.775-781
    • /
    • 2018
  • Shake table tests were conducted on scaled tunnel model to investigate the mechanism and effect of seismic loadings on horseshoe scaled tunnel model in ground fissure site. Key technical details of the experimental test were set up, including similarity relations, boundary conditions, sensor layout, modelling methods were presented. Synthetic waves and El Centro waves were adopted as the input earthquake waves. Results measured from hanging wall and foot wall were compared and analyzed. It is found that the seismic loadings increased the subsidence of hanging wall and lead to the appearance and propagation of cracks. The values of acceleration, earth pressure and strain were greater in the hanging wall than those in the foot wall. The tunnel exhibited the greatest earth pressure on right and left arches, however, the earth pressure on the crown of arch is the second largest and the inverted arch has the least earth pressure in the same tunnel section. Therefore, the effect of the hanging wall on the seismic performance of metro tunnel in earth fissure ground should be considered in the seismic design.

Allowable sound pressure levels of ceiling mounted air-conditioning sounds (천장형 에어컨 소음의 허용 음압레벨 도출)

  • You, Jin;Jeong, Choong-Il;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.689-692
    • /
    • 2008
  • Noises from ceiling mounted air-conditioning units were recorded in various actual situations such as offices, classrooms and libraries. Eight specimens of air-conditioners from major domestic and foreign manufacturers' were investigated in this study. A head and torso simulator was located 1.5 m beneath the air-conditioner panel for the measurements and sound pressure levels of the recording sounds were varied from 28 to 55 dBA with 3 dB steps for subjective evaluations. A total of 88 stimuli was randomly presented to subjects using a headphone system in semi-anechoic chamber. Two-categorized (noisiness and amenity) nine-point scale was used as evaluation method. The third scale ('point 3') among the nine-point scale was set as the threshold of allowable level of the air-conditioning sounds in consideration of the real situations. The results indicate that the allowable sound pressure level is around 34 dBA for both noisiness and amenity categories.

  • PDF

Maximal Inspiratory Pressure, Maximal Expiratory Pressure, and Maximum Phonation Time in Singers, Untrained Normal Person, and Patients with Vocal Cord Diseases (성악가와 성악훈련을 받지 않은 일반인과 성대질환이 있는 환자에서 최대흡기압, 최대호기압, 최대발성지속시간에 관한 연구)

  • 남도현;안철민;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.2
    • /
    • pp.117-123
    • /
    • 2002
  • MIP was significantly increased in singers, compared to the untrained group. MIP in patients showed decreasing tendency compared to the untrained group, but were significantly lower than that in singers. MEP in singers was higher than that in the untrained group. MPT increased significantly in singers, but diminished in patients compared to the untrained group. MIP, MEP, and MPT in male singers were 50.8%, 61.0%, and 28.7 % higher than those in female singers. MIP, MEP, and MPT in the untrained male were more increased 32.3%, 25.0%, and 28.7%, respectively than those in the untrained female. There was no correlation between MPT and MIP or MEP. Regression analysis of the data set showed that weight and vocal cord dysfunction was a positive predictor of MPT. Factors affecting MIP were male, singers and weight. Factors affecting MEP were male, singers, vocal cord dysfunction and weight.

  • PDF

Research for Design and Characteristic Interpretation of Capacitive Pressure Sensor Structure (용량형 압력 센서의 설계 및 특성해석에 대한 기초적 연구)

  • Park, Chang Yong;Kweon, Hyun Kyu;Zhao, Zhi Jun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.2
    • /
    • pp.1-7
    • /
    • 2015
  • In this paper, a new capacitive pressure sensor has been proposed for a displacement measurement. The new sensor is mainly composed of a gap of $5{\mu}m$ and a notch of $1{\mu}m$. And the sensor has the performance as the high sensitivity and capacitance compared with a commercial capacitive sensor. Therefore, the advantages of the new capacitive pressure sensor are good sensitivity in normal range, mechanically robust and large overload protection. The analytical model is induced for confirming the performance of the proposed sensor. In addition, FEM (finite elements method) simulation has been performed to verify the analytical model. Firstly, the displacement characteristics of diaphragm membrane were simulated by the analytical model and FEM in the case of different structure and materials. At last, through this analysis, these simulation results can be predicted the change of the performance when the device parameters are varied. And it is used as a design tool to achieve at a set of performance we desired.

The misfire detection using the mean exhaust pressure gradient index (평균 배기 압력 구배 지수를 이용한 실화 검출)

  • Chung, Sung-Won;Sim, Kook-Sang;Kim, Se-Woong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.4
    • /
    • pp.371-378
    • /
    • 2001
  • This paper proposes a method to detect the misfired cylinder using a new misfire detection index. The new method of misfired cylinder is a comparison of pressure gradient during the blowdown period of exhaust stroke. If a misfire occurs, the engine will he lost some power and consumes the more fuel and the torque will be unsteady. Most of all, the misfire affects a bad influence of the 3-way catalyst and emits unburned hydrocarbon in the air. To prevent these unusual phenomena and eliminate the factor of the environmental pollution, it is important to detect the misfired cylinder. To do the experiment, set up the assist device on the manifold. This assist device is not deformed for conventional exhaust manifold and installed in the end of the exhaust manifold. Experimental results showed that the method using the mean gradient pressure index is proven to be effective in the detection of misfired cylinder on gasoline engine regardless loads and revolutions of the engine.

  • PDF

Development Behavior of Vaporizing Sprays from a High-Pressure Swirl Injector Using Exciplex Fluorescence Method

  • Choi, Dong-Seok;Kim, Duck-Jool;Hwang, Soon-Chul
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.10
    • /
    • pp.1143-1150
    • /
    • 2000
  • The effects of ambient conditions on vaporizing sprays from a high-pressure swirl injector were investigated by an exciplex fluorescence method. Dopants used were 2% fluorobenzene and 9% DEMA (diethyl-methyl-amine) in 89% solution of hexane by volume. In order to examine the behavior of liquid and vapor phases inside of vaporizing sprays, ambient temperatures and pressures similar to engine atmospheres were set. It was found that the ambient pressure had a significant effect on the axial growth of spray, while ambient temperature had a great influence on the radial growth. The spatial distribution of vapor phase at temperatures above 473K became wider than that of liquid phase after half of injection duration. From the analysis of the area ratio for each phase, the middle part (region II) in the divided region was the region which liquid and vapor phases intersect. For liquid phase, fluorescence-intensity ratio was greatly changed at lms after the start of injection. However, the ratio of vapor phase was nearly uniform in each divided region throughout the injection.

  • PDF

MBR공정의 플럭스 향상 기술에 관한 연구

  • No, Seong-Hui;Kim, Seon-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.145-148
    • /
    • 2002
  • Membrane bioreactors for wastewater treatment must operate for long periods without chemical cleaning. This study investigates the critical flux concept introduced by Field et al. as a means for achieving this goal. We conducted two series of tests: at fixed transmembrane pressure(TMP) and at fixed permeate flux. set by a volumetric pump on the permeate. Comparison of constant pressure and constants flux tests under same conditions showed that the critical flux is almost identical to the limiting or pressure independent flux obtained in constant pressure. More generally, constant flux procedure below the critical flux avoids overfouling of the membrane in the initial stage and is more advantageous for membrane bioreactor operation.

  • PDF

Prediction of Biodiesel Combustion, CO and NOX Emission Characteristics in Accordance with Equivalence Ratio (당량비 변화에 따른 바이오디젤 연소 및 CO, NOX 생성 특성 예측)

  • Lim, Young Chan;Suh, Hyun Kyu
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • This study was performed to provide the basic information of the combustion, CO and $NO_X$ characteristics of biodiesel in accordance with equivalence ratio. The closed homogeneous reactor model used for the analysis. The analysis conditions were set to 900 K of the initial temperature, 20 atm of initial pressure and equivalence ratio was changes from 0.6 to 1.4. The results of analysis were predicted and compared in terms of combustion temperature, combustion pressure, CO and $NO_X$ emissions. The results of combustion characteristics showed that ignition delay was decreased and the combustion temperature and combustion pressure was increased in accordance with equivalence ratio. CO emission was decreased in lean condition(${\Phi}$ < 1.0), however, CO emission was increased in rich condition(${\Phi}$ > 1.0) because oxygen supply insufficient. $NO_X$ emission showed the largest amount in condition 0.8 of equivalence ratio because the oxygen concentration was sufficient.