• 제목/요약/키워드: Set Point Control

검색결과 581건 처리시간 0.03초

소형풍력발전시스템을 위한 퍼지로직 기반의 가변 스텝 사이즈 MPPT 제어 (Variable Step-Size MPPT Control based on Fuzzy Logic for a Small Wind Power System)

  • 최대근;이교범
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.205-212
    • /
    • 2012
  • This paper proposes the fuzzy logic based variable step-size MPPT (Maximum Power Point Tracking) method for the stability at the steady state and the improvement of the transient response in the wind power system. If the change value of duty ratio is set on stability of the steady state, MPPT control traces to maximum power point slowly. And if the change value is set on improvement of the transient response, the system output oscillates at the maximum power point. By adjusting the step size with fuzzy logic, it can be improved the MPPT response speed and stability at steady state when MPPT control is performed to track the maximum power point. The effectiveness of the proposed method has been verified by simulations and experimental results.

중앙냉방시스템의 준최적 설정점제어기법 구현에 관한 연구 (An Implementation for Near-Optimal Set Point Control for Central Cooling Systems)

  • 백승재;송재엽;안병천;주영덕;김진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.46-51
    • /
    • 2007
  • The near-optimal control algorithm for central cooling system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air temperature and chilled water temperature. This study has been done by using LapVIEW program with PID control in order to analyze the central cooling system energy saving.

  • PDF

지역난방 2차측 유량변화가 내부 열유속 및 에너지소비량에 미치는 영향에 관한 실험적 연구 (The Experimental Study of the Heat Flux and Energy Consumption on Variable Flow Rate for Secondary Side of DHS)

  • 홍성기;조성환
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.247-253
    • /
    • 2015
  • The presented work demonstrates the effects of flow rate on the secondary side of DHS (District Heating System). Increasing flow rate at the secondary side of DHS decreases energy consumption and time to reach the set-point of the heated room while increasing heat flux on the floor in the heating space. When flow rate increases, the overall heat transfer rate of radiant floor also increases. However, the results also show overall heat transfer rateto not increased linearly and thus the existence of an optimal flow rate for the secondary side of DHS. Control of the radiant floor with hot water may be more effectively accomplished with a combined control strategy that includes heat flux and a temperature set-point. This experimental analysis has been performed using a lab-scaled DHS pilot plant located at Jeonju University in Korea.

특징점들의 적응적 선택에 근거한 B-spline 곡선근사 (B-spline Curve Approximation Based on Adaptive Selection of Dominant Points)

  • 이주행;박형준
    • 한국CDE학회논문집
    • /
    • 제11권1호
    • /
    • pp.1-10
    • /
    • 2006
  • This paper addresses B-spline curve approximation of a set of ordered points to a specified toterance. The important issue in this problem is to reduce the number of control points while keeping the desired accuracy in the resulting B-spline curve. In this paper we propose a new method for error-bounded B-spline curve approximation based on adaptive selection of dominant points. The method first selects from the given points initial dominant points that govern the overall shape of the point set. It then computes a knot vector using the dominant points and performs B-spline curve fitting to all the given points. If the fitted B-spline curve cannot approximate the points within the tolerance, the method selects more points as dominant points and repeats the curve fitting process. The knots are determined in each step by averaging the parameters of the dominant points. The resulting curve is a piecewise B-spline curve of order (degree+1) p with $C^{(p-2)}$ continuity at each knot. The shape index of a point set is introduced to facilitate the dominant point selection during the iterative curve fitting process. Compared with previous methods for error-bounded B-spline curve approximation, the proposed method requires much less control points to approximate the given point set with the desired shape fidelity. Some experimental results demonstrate its usefulness and quality.

자동발전제어(AGC) 운용기선에 관한 연구 (A study on Improvement of Automatic Generation Control Related Systems for New Energy Management System)

  • 전동훈;추진부;윤용범;김성학;이진수;김국헌;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.357-359
    • /
    • 2000
  • This paper is to introduce the R&D project called "Improvement of Automatic Gene-ration Control Related Systems for New Energy Management system". The principal objective of this project is to demonstrate AGC operation capabilities that are suitable to new EMS environment and to show the validity of Set-Point Control Method. A number of developments and enhancements have been made to the generator's Remote Terminal Unit in which new ASTC is being developed and installed. The so-called ACC Signal Transfer Card(ASTC) will include RTU's Set-Point Control capabilities. It is expected that over next few months both RTU & DCS software modifications will be given and a relatively new Set-Point Control Method will be chosen instead of those from more conventional method, pulse control method.

  • PDF

농용(農用)트랙터의 3점 히치 시스템의 마이크로컴퓨터 제어(制御)(II) -성능시험(性能試驗)- (Microcomputer Control of Electronic-Hydraulic Three-Point Hitch for Agricultural Tractor(II) -Performance Test-)

  • 류관희;유수남;김영상
    • Journal of Biosystems Engineering
    • /
    • 제17권3호
    • /
    • pp.223-228
    • /
    • 1992
  • This study was conducted to develop an electro-hydraulic three-point hitch control system using an electro-hydraulic servo valve and microcomputer and to investigate the performance of the three-point hitch control system through indoor and field experiments. 1. The results from indoor experiments coincided with those from computer simulation reported in the previous paper. However, the draft control with the value 4 of Kd showed a slight sustained oscillation after it reached the draft set. 2. From the field experiments, it appeared that the RMS errors increased with the ground speed of tractor. In position control, the three-point hitch control system with electro-hydraulic servo valve showed better performance than that with on-off electro-magnetic valve in the ground speed less than 1.6 m/s. In draft control, however, there was no significant differece in performance between those two systems. 3. In depth control, the both types of electro-hydraulic three-point hitch control system showed better performance than the conventional mechanical-hydraulic three-point hitch control system.

  • PDF

다기의 FACTS 기기 협조제어 시스템 개발 (Development of Cooperated Control System for Multiple FACTS in KEPCO Power Systems)

  • 장병훈
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1726-1730
    • /
    • 2008
  • In this paper, the application schemes for coordinated control system of multiple FACTS were presented to enhance the voltage stability around the metropolitan areas. In order to coordinated control of FACTS devices, f-V analysis method which is one of the indices for voltage stability was performed with real time network data which is transferred from SCADA/EMS system. If the system is unstable after contingencies, the new operation set-point of FACTS would be determined using bus sensitivity from tangent vector at voltage instability point. Otherwise, we would determine the new operation set-point of FACTS for considering economical operation, like as active power loss minimization using Optimal Power Flow algorithm. In simulation, the SCADA/EMS 2007's data are used for studying the coordinated control algorithm of multiple FACTS devices that is installed or will be installed in KOREA power system

Magnetic Field Correction Method of Magnetometers in Small Satellites

  • Lee, Seon-Ho;Rhee, Seung-Wu;Ahn, Hyo-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.36-40
    • /
    • 2003
  • The considered satellite is supposed to operate in the earth-point mode and sun-point mode in accordance with the mission requirements. The magnetic field correction is based on the orbit geometry using a set of measured magnetic field data from the three-axis-magnetometer and its algorithm excludes the earth’s magnetic field model. Moreover, the usefulness of the proposed method is investigated throughout the simulation of KOMPSAT-1.

  • PDF

Fault-Tolerant Control for 5L-HNPC Inverter-Fed Induction Motor Drives with Finite Control Set Model Predictive Control Based on Hierarchical Optimization

  • Li, Chunjie;Wang, Guifeng;Li, Fei;Li, Hongmei;Xia, Zhenglong;Liu, Zhan
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.989-999
    • /
    • 2019
  • This paper proposes a fault-tolerant control strategy with finite control set model predictive control (FCS-MPC) based on hierarchical optimization for five-level H-bridge neutral-point-clamped (5L-HNPC) inverter-fed induction motor drives. Fault-tolerant operation is analyzed, and the fault-tolerant control algorithm is improved. Adopting FCS-MPC based on hierarchical optimization, where the voltage is used as the controlled objective, called model predictive voltage control (MPVC), the postfault controller is simplified as a two layer control. The first layer is the voltage jump limit, and the second layer is the voltage following control, which adopts the optimal control strategy to ensure the current following performance and uniqueness of the optimal solution. Finally, simulation and experimental results verify that 5L-HNPC inverter-fed induction motor drives have strong fault tolerant capability and that the FCS-MPVC based on hierarchical optimization is feasible.

실제 일사량 조건에서의 최적 MPPT 제어주기 (Optimum MPPT Control Period for Actual Insolation Condition)

  • 류단비;김용중;김효성
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.99-104
    • /
    • 2019
  • Solar power generation systems require maximum power point tracking (MPPT) control to acquire maximum power using inefficient and high-cost PV modules. Most conventional MPPT algorithms are based on the slope-tracking concept. The perturb and observe (P&O) algorithm is a typical slope-tracking method. The two factors that determine the MPPT performance of P&O algorithm are the MPPT control period and the magnitude of the perturbation voltage. The MPPT controller quickly moves to the new maximum power point at insolation change when the perturbation voltage is set to large, and the error of output power will be huge in the steady state even when insolation is not changing. The dynamics of the MPPT controller can be accelerated even though the perturbation voltage is set to small when the MPPT control period is set to short. However, too short MPPT control period does not improve MPPT performance but consumes the MPPT controller resources. Therefore, analyzing the performance of the MPPT controller is necessary for actual insolation conditions in real weather environment to determine the optimum MPPT control period and the magnitude of the perturbation voltage. This study proposes an optimum MPPT control period that maximizes MPPT efficiency by measuring and analyzing actual insolation profiles in typical clear and cloudy weather in central Korea.