• 제목/요약/키워드: Server display monitor

검색결과 21건 처리시간 0.036초

공유메모리를 이용한 효율적인 감시 영상 표출 방안 (A Plan of Efficient Images Display Using Shared Memory)

  • 이원재;안태기;신정렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3306-3311
    • /
    • 2011
  • Last Subway video surveillance system consists of a network device that is used. Through the network to transmit video data to digital conversion of analog video via a process server or a PC video to a split-screen in various forms is expressed. In recent years, multi-monitor video cameras from the same pop-up or more, such as history, structure expressed on a variety of video is required by express. The problem with these systems, video compression and transmission of many cameras, and this image data received from the server or PC to take out all the images you want to watch to occur when in order to express all of the images because of the need to decode most of the program per limit of number of channels is positioned. This limited number of channels to have a video that nothing forced, but it is likely to do so in the future performance of the hardware evolves gradually channeled images available number of channels will increase proportionately. However, as the development of hardware required for a single screen video channel will be more gradual capital. The hardware rather than relying solely on the performance of the decoded video data on the screen in order to express a more efficient utilization of shared memory for video surveillance software will provide the operating plan.

  • PDF

The Design of Reliable Graphics-DTV Signal Converter Using EDAC Algorithm in DTV System

  • Ryoo, Dong-Wan;Lee, Jeun-Woo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2126-2130
    • /
    • 2003
  • In the integrated systems, that is integrated digital TV(DTV) internet and home automation, like home server, is needed integration of digital TV video signal and computer graphic signal. The graphic signal is operating at the high speed and has time-divide-stream. So the re-request of data is not easy at the time of error detection. therefore EDAC algorithm is efficient. In this paper, we show a scheme, that is integration of graphic and dtv format signal for DTV monitor display. This paper also presents the efficiency error detection auto correction(EDAC) for conversion of graphics signal to DTV video signal. A presented EDAC algorithms use the modified hamming code for enhancing video quality and reliability. A EDAC algorithm of this paper can detect single error, double error, triple error and more error for preventing from incorrect correction. And it is not necessary an additional memory. In this paper The comparison between digital TV video signal and graphic signal, a EDAC algorithm and a design of conversion graphic signal to DTV signal with EDAC function in DTV system is described.

  • PDF

RFID를 이용한 특수 자산 관리 시스템 개발 (Development of Special Asset Management System Using RFID)

  • 한상훈;민장근
    • 한국콘텐츠학회논문지
    • /
    • 제11권6호
    • /
    • pp.33-41
    • /
    • 2011
  • RFID기술은 이미 신분증, 교통카드 등 다양한 응용분야에 사용되고 있으며, UHF 대역의 RFID 기술은 물류, 유통, 보안 분야에서 많은 시스템들이 개발되어 왔다. 또한, 사람에 의해서 관리되는 허점을 보완하기 위해서 총기, 보석과 의약품과 같은 특수자산을 효율적으로 통합 관리하고, 실시간 모니터링이 가능한 시스템을 필요로 한다. 본 연구에서는 특별하게 관리되어져야 하는 특수자산을 안전하게 보관하고, 상태를 실시간으로 모니터링 가능하며, 자산의 유통 경로 및 이력 관리를 할 수 있는 특수자산 관리 시스템을 개발하고자 한다. 시스템의 형태는 캐비닛의 형태를 가지고 있기 때문에 스마트 캐비닛이라고 한다. 스마트 캐비닛은 RFID, 다양한 센서, 지문 인식, 스마트카드 등의 기술을 통합하여 특수자산을 안전하게 보호하며, 관리 서버와의 통신을 통하여 자산의 실시간 감시, 이력 관리, 유통 경로, 보안로그 등을 제공한다. 본 연구에서는 특수자산 관리시스템을 구성하는데 있어서 총기 및 의약품 관리 스마트 캐비닛을 개발하였으며, 이에 대한 효용성 및 가능성을 제시하였다.

차량진단 및 모니터링을 위한 통신과 서버시스템 운용에 관한 연구 (Research on Communication and The Operating of Server System for Vehicle Diagnosis and Monitoring)

  • 유희수;원용관;박권철
    • 대한전자공학회논문지TC
    • /
    • 제48권6호
    • /
    • pp.41-50
    • /
    • 2011
  • 본 논문은 차량의 엔진 및 내부 고장을 잘 알지 못하는 차량운전자들을 위해 휴대기기를 이용한 차량의 운행, 고장, 이상 정보를 모니터링하고 인터넷 환경에서 자료를 조회할 수 있는 서버시스템 운용에 관한 것이다. 운행 중 실시간으로 차량의 상태를 알려주기 위하여 기존의 네비게이션 및 GPS 위주의 텔레메틱스 기술에서 벗어나 차량 내부 망(In-Vehicle Network)에 연결된 엔진, 트랜스미션, 브레이크, 에어백 등의 제어장치인 ECU(Electronics Control Unit) 및 각종 센서들로부터의 데이터 획득을 위해 차량내의 OBD-II(On-Board Diagnostics) 커넥터에 직접연구 개발한 차량 정보 수집 장치를 연결한다. 또한, 무선 통신통신이 가능한 휴대기기(휴대폰, PDA, PMP, UMPC 등)에 차량 진단 프로그램을 탑재하여 차량 주행 중에 발생되는 운행, 고장, 이상 정보를 실시간으로 수집 및 분석한다. 이상 징후 발생 시 알림 메시지를 발생하여 차량의 이상에 대해 신속히 대처 할 수 있다. 이와 동시에, 휴대기기를 통해 수집된 차량 정보 데이터는 무선통신망을 통해 차량 관리 전문회사의 서버로 전송되고, 체계적인 차량 관리에 활용될 수 있도록 하기 위해 구축된 서비스 시스템에서 조회 및 활용되어지게 된다. 따라서 차량에 대한 지식이나 상식이 부족한 모든 운전자에게 차량 관리에 대한 편리함을 제공하여 안전운전 및 경제운전에 관련된 운전이력관리 등의 서비스를 제공할 수 있다. 이러한 편리성을 제공하고자 본 연구에서는 차량에 탑재되는 차량 정보 수집 장치와 운전자가 사용 중인 개인의 무선통신 휴대기기와 인터넷망으로 연계되는 차량 진단 및 모니터링이 가능한 시스템을 구성하였고, 자료의 조회 관리 기술을 연구하였다.

선박종합정보시스템의 개발에 관한 연구 (A Study on Development of Integrated System of Ship's Information)

  • 정태권;박수한
    • 한국항해항만학회지
    • /
    • 제31권8호
    • /
    • pp.645-652
    • /
    • 2007
  • 이 논문에서는 현재 선박의 운항 기능을 보다 향상시키는 방법의 하나로서 경제적이고 효율적인 "선박종합정보시스템"을 개발하였다. 이것은 선박의 운항 정보 및 주변 상황을 한 눈에 정확히 파악할 수 있도록 데이터를 종합적이고 체계적으로 선내 통신망을 기반으로 통합하고, 선내 뿐 만아니라 위성데이터통신을 이용하여 원격으로 육상에서 실시간으로 다중의 사용자가 동시에 이를 감시, 기록, 분석을 통하여 선박운항을 지원할 수 있는 시스템이다. 선박종합정보시스템은 선박신호연동장치를 통해 수신된 항해/기관/경보 데이터를 선박종합통신망에 적절하게 전송하는 데이터 분배 프로그램, 항해/기관 데이터를 저장하고 관리하는 데이터베이스, 항해/기관/경보 데이터를 표시하여 선박의 운항 상황 및 주변 상황을 감시하는 각종 정보프로그램, 선박이 건조되어 폐선될 때까지의 관리에 관한 선박관리프로그램, 기타 응용 프로그램으로 구성되어 있다.

무선센서네트워크 기반의 가속도 맥파를 이용한 유비쿼터스 헬스케어 모니터링 시스템 (Ubiquitous Healthcare Monitoring System using APG Signals based on Wireless Sensor Network)

  • 정상중;이훈재;정완영
    • 한국정보통신학회논문지
    • /
    • 제13권4호
    • /
    • pp.813-820
    • /
    • 2009
  • 본 논문에서는 웨어러블 펄스 옥시미터를 이용하여 IEEE 802.15.4기반의 무선센서네트워크 환경에서 측정에 대한 외부의 자각 없이 자유스러운 생활 속에서 측정 가능한 유비쿼터스 헬스케어 시스템을 구현하고자 하였다. 환자로부터 산소포화도 데이터를 측정하기 위해 반사형 프로브, 산소포화도 모듈, 그리고 무선센서 노드로 구성된 저전력 웨어러블 펄스 옥시 미터를 구현하였다. TinyOS 어플리케이션기의 무선센서 노드는 제작된 프로브로부터 측정 된 데이터를 수집하여 무선통신을 위한 패킷을 구성하며, 무선센서 네트워크를 통해 베이스 스테이션으로 전송된 데이터는 서버 PC에서의 모니터링과 데이터 처리 및 저장이 가능하게 하였다. 서버 PC에서는 LabVIEW소프트웨어 프로그램을 통해 전송된 산소포화도 데이터가 실시간 모니터링 되며, PPG 파형의 2차 미분처리를 통해 동맥혈의 상태를 추정 할 수 있는 가속도 맥파(APG)를 검출하도록 하였다. 또한 실제 연령대별 실험을 통해 가속도 맥파에 의한 혈관 탄성도의 수치를 비교분석 하였다.

무선 센서 네트워크를 통한 실시간 항공기 유해가스 감지 임베디드 시스템 개발 (Development of Real time Aircraft harmful gas detecting Emebedded system through wireless sensor network)

  • 최원혁;지민석
    • 한국항행학회논문지
    • /
    • 제17권6호
    • /
    • pp.672-678
    • /
    • 2013
  • 본 논문에서는 최근 정보통신 기술의 발전으로 인해 IT와 전통산업 간의 융합 기술을 적용한 응용서비스가 대두되고 이를 이용한 유해가스 감지 응용서비스로 자동 및 원격으로 항공기내환경을 모니터링하여 제어하고 유지 관리할 수 있는 무선 센서 네트워크기반의 유해가스환경 감지시스템에 대해 활발하게 논의되고 있다. 본 논문에서는 유해가스를 측정하여 모니터링 장치로 전송하는 무선 센서 네트워크센서노드, 센서노드로부터 수집한 데이터를 취합하고 디스플레이 및 서버로 환경정보를 전송하는 모니터링 관리장치와 또한 원격 모니터링을 위한 PC/스마트폰 기반 사용자 운용프로그램으로 구성하여, 항공기내에서 발생하는 유해가스 가스를 측정하고, 모니터링하는 무선 센서 네트워크기반의 실시간 모니터링 시스템을 설계하고 구현한다.

모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양 (Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications)

  • 우응제;박승훈;전병문;문창욱;이희철;김승태;김형진;서재준;채경명;박종찬;최근호;이왕진;김경수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

공연장에서 다중 몰입도 측정을 위한 시스템 개발 (System Development for Measuring Group Engagement in the Art Center)

  • 류준모;최일영;최이권;김재경
    • 지능정보연구
    • /
    • 제20권3호
    • /
    • pp.45-58
    • /
    • 2014
  • 몰입은 관람객이 콘텐츠를 관람할 때 관람객들이 콘텐츠에 몰두하고 있는 심리적 상태를 의미하는 것으로, 관람객의 몰입경험은 콘텐츠의 만족도에 긍정적인 영향을 미친다. 따라서 공연 같은 콘텐츠를 제공하는 기업들은 콘텐츠의 흥행을 위해 관람객의 몰입도를 측정하는 것은 매우 중요하다. 설문 등의 표본조사 방법을 통해 관람객의 몰입도를 측정 연구는 방송분야 등 에서 널리 사용되고 있다. 이러한 몰입도 측정방법은 콘텐츠 관람 이후 설문을 실시하기 때문에 몰입도를 실시간으로 측정할 수 없을 뿐만 아니라 몰입도 측정의 정확성이 저하되는 문제 등이 있다. 이러한 문제를 해결하기 위하여 생리적 반응이나 얼굴 표정 분석, 그리고 움직임 관찰 방법 등을 이용하여 몰입도를 측정하는 연구가 수행되고 있다. 생체 신호를 이용하여 몰입도를 측정하는 연구의 경우, 1인을 대상으로 생체신호를 측정할 뿐만 아니라, 많은 데이터 처리 시간과 비용이 소모되는 단점이 있어 많은 관람객이 관람하는 공연장에 적용하기에는 한계가 있다. 얼굴 표정인식 통해 몰입도를 측정하는 경우도 1인을 대상으로 하고 있으며, 밝은 조명의 실험실 환경에서만 가능하다는 단점이 존재한다. 또한 관람객들의 움직인 동기화를 이용하여 몰입도를 특정한 연구는 다중관객을 대상으로 하였지만, 이는 실험실 환경에 한정하여 적용된 사례이다. 따라서 본 연구에서는 공연장, 시사회관 등 많은 관람객들이 콘텐츠를 관람하는 실제 환경에서 다중관람객이 다중몰입도의 정량적 평가를 위한 시스템을 설계하고 개발하였다. 제안된 시스템은 외부장치, 서버, 내부장치 등의 3부분으로 구성되어 있다. 서울시 마포구 상암동에 위치한 DMC 홍보관에 상설 전시장으로 운영하고 있으며, 관람객들을 대상으로 데이터를 획득하고 있다. 제안하고 있는 시스템을 활용하면 콘텐츠의 어느 구간에서 관객들이 몰입을 하고 있는지, 어느 구간에서 몰입을 하고 있지 못한지 분석가능하기 때문에, 향후 콘텐츠 제작 및 마케팅에 유용하게 활용할 수 있을 것으로 기대된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF