• Title/Summary/Keyword: Series transformer

Search Result 349, Processing Time 0.05 seconds

Comparison of Characteristics on the Flux-Lock and the Transformer Type SFCLs with Three Superconducting Units (3개의 초전도 소자를 갖는 자속구속형 SFCL과 변압기형 SFCL의 특성 비교)

  • Lee, Ju-Hyoung;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.1
    • /
    • pp.79-84
    • /
    • 2009
  • In order to increase the capacity of the superconducting fault current limiter(SFCL), the current and voltage grades of the SFCL must be increased. As a method for the increase of the current and voltage grades of the SFCL, we compared the various characteristics between the flux-lock type SFCL "With three superconducting units connected in series and the transformer type SFCL using the transformer with three secondary circuits. One of three superconducting units had not quenched in the flux-lock type SFCL. Therefore, the unbalanced power burden happened because of the voltage difference generated by unbalanced quenching between the superconducting units. In the meantime, the three superconducting units were all quenched in the transformer type SFCL using the transformer, and the voltage difference generated between the superconducting units was decreased. Therefore, the difference of critical characteristics was complemented by distribution of fault current in accordance with the turn's ratio between primary and secondary windings. The unbalanced power burden of the superconducting units was reduced due to flux-share between the superconducting units in the transformer. In conclusion, the capacity increment of the SFCL using a transformer was easier due to equal distribution of voltages generated by simultaneous quench of the superconducting units. We think that the characteristics is improved more because of the decrease of saturation in the iron core if the secondary winding is increased in the SFCL using the transformer.

Series Resonant Full Bridge Inverter for Battery-fed Microwave Oven (배터리 구동 전자레인지를 위한 직렬 공진형 풀브릿지 인버터)

  • 鄭 龍 采;韓 盛 軫
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.165-170
    • /
    • 2002
  • In order to solve the problem of system efficiency reduced on account of two stage power conversion, we propose a series resonant full bridge Inverter circuit for battery-fed microwave oven. This circuit has both a compact size and a light weight comparing with the conventional HVT(High Voltage Transformer) method. Also, it may be adjusted power levels of the microwave oven by a frequency control. In this paper, operational principles are explained in detail in order to understand the circuit operation. Also, a proto-type Inverter circuit with 1[kW] Power consumption is built and tested for verifying the operation.

Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator (3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석)

  • Song, W.H.;Park, H.Y.;Nho, E.C.;Kim, I.D.;Kim, H.G.;Chun, T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.71-72
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

Switching Characteristics Analysis of Bypass SCR for Series Transformer in 3-phase Voltage Disturbance Generator (3상 전압변동발생기의 직렬변압기 바이패스용 SCR의 스위칭 특성해석)

  • Song, W.H.;Park, H.Y.;Nho, E.C.;Kim, I.D.;Kim, H.G.;Chun, T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.532-533
    • /
    • 2010
  • This paper deals with the SCR thyristor switching characteristics of a 3-phase voltage disturbance generator. The series transformers of the generator require bypass SCR thyristors to provide the source voltage to the output terminal in normal operating mode. The SCR thyristor switching characteristics is quite different according to the connection point to the series transformer. The switching characteristics is analysed and verified through simulation results.

  • PDF

An improved high efficiency resonant converter with low coupling transformer (낮은 커플링 변압기를 갖는 개선된 고효율 공진 컨버터)

  • Kong Y. S.;Kim E. S.;Yang S. C.;Park J. Y.;Kim J. M.;Kang D. H;Cho J. G.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1166-1168
    • /
    • 2004
  • The high frequency series resonant converter has been widely used for the non-contact power supply system with the large air gap and the increased leakage inductance of the non-contact transformer. However. the high frequency series resonant converter has the disadvantages of high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, unit voltage gain is revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation results and the 5kW experimental prototype.

  • PDF

A Study on CCC(Capacitor Commutated Converter) and CSCC(Controlled Series Capacitor Converter) for HVDC System

  • Kim Chan-Ki;Kho Bong-Un;Lee Jong-Min;Chae Young-Mu
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.523-528
    • /
    • 2001
  • This paper deals with two non-conventional HVDC system, that are, the Capacitor Commutated Converter (CCC) in which series capacitors are included between the converter transformer and the valves, and the Controller Series Capacitor Converter (CSCC), based on more conventional topology, in which series capacitors are inserted between the AC filter bus and the AC network. The simulation waveforms show that if these compare to conventional HVDC, these HVDC systems have many advantages in steady-state and transient performance.

  • PDF

A Single Switched Series Element of Series-Parallel Compensated UPS (직병렬 보상형 무정전 전원장치의 단일 스위치 직렬 요소)

  • 이인우;박진형;전성즙
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.106-109
    • /
    • 1999
  • A single-switched series element for series-parallel compensated UPS is proposed. The proposed series element can handle only unidirectional power and the input voltage must be higher than the output voltage. But it is very useful when DC-link voltage is low and isolation transformer is need for output stage since only one active switch is used.

  • PDF

Analysis on Current Limiting Characteristics of Flux-Lock Type SFCL Using a Transformer Winding (변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 특성 분석)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.136-140
    • /
    • 2011
  • The fault current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL) using a transformer winding were investigated. The suggested flux-lock type SFCL consists of two parallel connected coils on an iron core and the transformer winding connected in series with one of two coils. In this SFCL, the high-TC superconducting (HTSC) element was connected with the secondary side of the transformer. The short-circuit experimental devices to analyze the fault current limiting characteristics of the flux-lock type SFCL using the transformer winding were constructed. Through the short-circuit tests, the flux-lock type SFCL using transformer winding was shown to perform more effective fault current limiting operation compared to the previous flux-lock type SFCL without the transformer winding from the viewpoint of the quench occurrence and the recovery time of the HTSC element.

Lifetime Loss Calculation for Asset Management of a Power Transformer (송변전 변압기 자산관리를 위한 수명손실 계산)

  • Lee, Onyou;Lee, Hongseok;Jeon, Sangsu;Jeong, Minkyung;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.70-74
    • /
    • 2018
  • Social infrastructure such as production, transportation, gas, and electrical facilities would be degraded according to time and those facilities might need more maintenances, repairing, and management as time goes by. Especially, in the case of a power transformer, it is important to diagnose the transformer in order to avoid malfunction and failure because they could cause enormous damage. The economic as well as technical aspects of a transformer management must be considered while it is operated. Therefore, the concept of asset management should be applied as an advanced method of transformer management. Asset management refers to a series of processes to make a plan of maintenance and conservation of a power transformer considering the soundness, investment cost, and importance of equipment. It is important to apply the asset management considering calculation of a lifetime loss. In this paper, the lifetime loss calculation method of asset management for a power transformer is suggested.

Influence of a Neutral Line on the Quench Behaviors of a Transformer Type SFCL (변압기형 초전도 한류기의 퀜치특성에 대한 중성선의 영향)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Koo, Kyung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2212-2213
    • /
    • 2008
  • In this paper, we studied the method for simultaneous quenching of a transformer type superconducting fault current limiter (SFCL) with two superconducting elements connected in series. Only an element between two elements of the transformer type SFCL was quenched like the case of the resistive type SFCL. By this quenching characteristics, the power burden of the superconducting element was increased. In order to solve this problem, we connected the neutral line between two superconducting elements and the center of secondary coils. The two elements were all quenched in the transformer type SFCL with a neutral line. As a result, the power burden of superconducting elements was decreased, so it was efficient for the increase of power capacity of the transformer type SFCL.

  • PDF