• 제목/요약/키워드: Series system

검색결과 5,709건 처리시간 0.042초

Joint reliability importance of series-parallel systems

  • Dewan, I.;Jain, K.
    • International Journal of Reliability and Applications
    • /
    • 제12권2호
    • /
    • pp.103-116
    • /
    • 2011
  • A series-parallel system with independent but non-identical components is considered. The expressions have been derived for the joint reliability importance (JRI) of m (${\geq}2$) components, chosen from a series-parallel system. JRIs of components of two different series-parallel systems are studied analytically and graphically.

  • PDF

통신 기지국 전원용 주파수 제어 직렬 공진형 컨버터 시스템 (Frequency Controlled Series Resonant Converter System for Power Supply of Communication Station)

  • 지준근;임영하
    • 한국산학기술학회논문지
    • /
    • 제4권4호
    • /
    • pp.323-328
    • /
    • 2003
  • 본 논문에서는 통신 기지국용 전원으로 사용할 수 있는 직렬 공진형 컨버터 시스템의 새로운 제어방식을 제안하였다. 주파수 제어 직렬 공진형 컨버터 시스템은 병렬 출력 직렬 공진(Parallel Output Series Resonant: POSR)형태이기 때문에 부하변동에 강인하다. 또한 스위칭 주파수를 제어함으로써 입력전압의 변화에도 안정된 출력을 제공한다. 실제 시스템 제작에 앞서 제안된 병렬 출력 직렬 공진형 컨버터 시스템의 분석을 하였고 ACSL(Advanced Continuous Simulation Language)을 이용한 모의실험을 하였다. 또한 실제의 시스템을 제작 및 실험을 통하여 시스템 특성을 확인하였다.

  • PDF

공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수 (The optimal parameters in series-series counterflow chillers system within air conditioning)

  • 웬민푸;뷔옥훙;이근식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF

제어용 전원으로 사용가능한 공진형 컨버터 시스템 (Resonant Converter System for Control Power Supply)

  • 지준근;임영하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.69-72
    • /
    • 2003
  • In this paper new control strategy of series resonant converter system for control power supply is suggested. Frequency controlled series resonant converter system is robust to load variations because it is POSR(parallel output series resonant) type. And it provides stable output voltage by changing switching frequency to input voltage variations. Firstly, operation analysis about suggested series resonant converter system was carried. Then simulations using ACSL(Advanced Continuous Simulation Language) and experiments to actual system were carried to prove characteristics of suggested system.

  • PDF

ESTIMATION OF SYSTEM RELIABLITY FOR REDUNDANT STRESS-STRENGTH MODEL

  • Choi, In-Kyeong
    • Journal of applied mathematics & informatics
    • /
    • 제5권2호
    • /
    • pp.277-284
    • /
    • 1998
  • The reliability and an estimate for it are derived for series-parallel and parallel-deries stress-strength model under assumption that all components are subjected to a common stress. We also obtain the asymptotic normal distribution of the estimate.

3상 3선식 시스템의 고조파 저감을 위한 직렬형 능동전력필터에 관한 연구 (A Study on the series Active Power Filter for Harmonic Reduction of 3-Phase 3-Wire System)

  • 한윤석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.735-738
    • /
    • 2000
  • In this paper we propose a series active power filter and a simple calculation method acquiring the reference voltage. A series active power filter is suitable to suppress harmonics produced by voltage type harmonic source such as a diode rectifier with filter capacitor on the DC side The proposed series active power filter system is applied to 3-phase 3-wire power system including the voltage type harmonic source. Experimental result obtained from a laboratory model are shown to verify the viability and effectiveness of the proposed system.

  • PDF

성능함수제어 알고리즘을 이용한 3상 4선식 하이브리드형 직렬능동전력필터 (Hybrid Series Active Power filter Based on Performance Function Theory for 3-Phase 4-wire System)

  • 김진선;신재화;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1096-1098
    • /
    • 2003
  • In this paper, the control algorithm and control methods for a combined system of shunt passive filter and series active filter in 3-phase 4-wire system are discussed. Moreover, the 3-phase 4-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and odd multiples of $3^{rd}$($9^{th}$, $15^{th}$, etc.) are termed as triple and zero sequence components that do not cancel each other in the system neutral. As a result, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control scheme for a series hybrid active system. This series active power filter acts not only as a harmonic compensator but also as a harmonic isolator. Hence the required rating of the series active filter is much smaller than that of a conventional shunt active filter. However, the performance of the combined system is greatly influenced by the filtering algorithm employed in the active power filter. This paper proposes a series active power filter scheme based on performance function. Some experiments was executed and experimental results from a prototype active power filter confirm the suitability of the proposed approach.

  • PDF

체계중복 설정문제에 있어서 Redundancy 우선배치에 관한 연구 (A study for setting prior allocation of redundancy in parallel series system)

  • 조남호
    • 산업경영시스템학회지
    • /
    • 제9권14호
    • /
    • pp.45-48
    • /
    • 1986
  • This paper studies reliability growth model in redundancy allocation of Parallel-series system in which several series system is linked parallelly, The model is generalized by system redundancy of sub-system that have components redundancy. The stage of components in each sub-system is established differently. At the same time by assigned the different number of constraints to the sub-system, this paper deals with rather practical reliability growth model.

  • PDF

저궤도 인공위성용 Regulated Peak Power Tracking(RPPT) 시스템을 위한 단순화된 직-병렬 구조 (A Simplified Series-Parallel Structure for the RPPT (Regulated Peak Power Tracking) system)

  • 양정환;배현수;이재호;조보형
    • 전력전자학회논문지
    • /
    • 제13권2호
    • /
    • pp.110-118
    • /
    • 2008
  • 기존의 저궤도 인공위성 전력계 시스템에 사용된 직렬 구조, 병렬 구조는 공전 주기 동안 두 번의 전력변환 과정을 거쳐 시스템의 효율을 감소시킨다. 직-병렬 구조는 한 번의 전력변환 과정을 거쳐 시스템의 효율을 향상시키지만 레귤레이터가 추가됨으로써 시스템의 비용과 무게, 크기를 증가시킨다. 본 논문에서는 레귤레이터의 추가 없이 시스템의 효율을 향상시키는 단순화된 직-병렬 구조를 제안한다. 인공위성이 지구를 공전하는 동안 상황에 따라 변화하는 제안한 구조의 동작을 네 가지 모드로 분류하고, 각 모드마다 제안한 시스템을 안정적인 동작을 확인하기 위하여 대신호 분석을 수행하였다. 실험을 통하여 기존의 직렬구조와 제안한 구조의 효율을 비교하였다. 제안한 구조의 안정적인 동작을 검증하기 위해 200W급 태양전지와 TMS320F2812 DSP로 제어되는 100W급 전력조절기 두 모듈을 병렬로 구성하여 실험하였다.

이동통신 기지국용 SMPS 개발 연구 (Research on Development of SMPS used in a Base Station for Mobile Communication)

  • 지준근
    • 한국산학기술학회논문지
    • /
    • 제6권3호
    • /
    • pp.278-284
    • /
    • 2005
  • 본 논문에서는 통신 기지국용 전원으로 사용할 수 있는 위상 제어 직렬 공진형 컨버터 시스템을 제안하고 동작 원리 및 특성을 살펴보았다. 위상 제어 직렬 공진형 컨버터 시스템은 POSR(Parallel Output Series Resonant) 형태이기 때문에 부하에 강인하고 MOSFET스위치의 위상을 제어함으로써 입력전압의 변화에도 안정된 출력을 보여준다 먼저 시스템의 분석과 PSIM프로그램을 사용한 시뮬레이션을 하였고, 또한 실제 시스템의 실험을 통하여 시스템의 특성을 확인하였다.

  • PDF