• Title/Summary/Keyword: Series resonant inverter

Search Result 161, Processing Time 0.021 seconds

A Study on Modeling of High-Frequency Leakage Currents in PWM Inverter Feeding an Induction Motor (유도전동기의 PWM제어와 누설 축전류 발생 모델링에 관한 연구)

  • 이재호;임경내;전진휘;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.221-224
    • /
    • 1998
  • A PWM inverter with an induction motor often has a problem with a high-frequency leakage current that flows through the distributed electrostatic capacitance from the motor windings to ground. This paper presents an equivalent circuit for high-frequency leakage currents in PWM inverter feeding an induction motor, which forms an LCR series resonant circuit.

  • PDF

High Power Factor Dual Half Bridge Series Resonant Inverter for an Induction Heating Appliance with Multiple Loads (다부하를 갖는 유도가열기기를 위한 고역률 이중 하프브릿지 직렬공진 인버터)

  • 정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.307-314
    • /
    • 1998
  • A novel high power factor Dual Half Bridge Series Resonant Inverter (DHB-SRI) for an induction heating appliance with multiple loads is proposed to remove the interferential acoustic noise caused by the difference between operating frequencies of adjacent loads. The circuit enables independent full power range control of two induction heating elements by one inverter circuit and has minimum switching losses due to the zero voltage switching characteristic. According to the mode analysis, I will explain the operation of the proposed circuit. To evaluate the required cooling capacity, loss analysis is performed through deriving some loss equations. In order to obtain the power factor correction capability and to lessen the system size, suitable design guides are given. Using the designed values, the proto-type circuit with 2.8kW power consumption for each induction heating element is built and tested to verify the operation of the proposed circuit.

  • PDF

A Study on Modeling and Damping of High-Frequency Leakage Currents in PWM Inverter Feeding an Induction Motor (PWM 인버어터로 구동되는 유도 전동기의 고주파 누설전류 모델링 및 억제에 관한 연구)

  • 이재호;전진휘;홍정표;강필순;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.18-22
    • /
    • 1998
  • A PWM inverter with an induction motor often has a problem with a high frequency leakage current that flows through stray capacitor between stator windings and a motor frame to ground. This paper presents an equivalent circuit for high frequency leakage currents in PWM inverter feeding an induction motor, which forms an LCR series resonant circuit. A conventional common mode ckoke or reactor in series between the ac terminals of a PWM inverter and those of an ac motor is not effective to reduce the rms and average values of the leakage current, but effective to reduce the peak value. Furthermore, this paper proposes a leakage current damper which is different in damping principle from the conventional common mode choke. It is shown theoretically and experimentally that the leakage current damper is able to reduce the rms value of the leakage current to 25%, where the core used in the leakage current damper is smaller than that of the conventional common-mode choke

  • PDF

Development of Full-Bridge High-Frequency Resonant Inverter for Electromagnetic Induction Heating (전자유도가열용 Full-Bridge 고주파 공진형 인버터의 개발)

  • 권혁민;신대철;김용주;김기환
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2943-2946
    • /
    • 2003
  • In this paper are described the indirect induction healed boiler and induction boated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20[kHz]to 50[kHz]. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

A Study on the Development of Induction Heating System for Using Full-Bridge High-Frequency Resonant Inverter (Full-Bridge 고주파 공진형 인버터를 이용한 유도가열시스템의 개발에 관한 연구)

  • Kwon H.M.;Kim S.H.;Shln D.C,;Kim Y.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.19-22
    • /
    • 2003
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 [kHz] to 50 [kHz]. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

An Optimal Design of LCC Resonant Inverter for Electronic Ballast to Drive HID Lamp (HID 램프를 위한 전자식 안정기의 LCC 공진 인버터의 최적 설계)

  • Park, Chong-Yeun;Jang, Mog-Soon;Lim, Byoung-Noh
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.531-537
    • /
    • 2007
  • This paper presents a new method for determining L, Cs, and Cp in a series parallel resonant inverter. This inverter is suitable for driving high-intensity discharge (HID) lamps. The operating frequency is selected to avoid acoustic resonances which are governed by the size and shape of the arc tube. L, Cs and Cp, are chosen to satisfy the ignition and steady state requirements of the lamp. Equations are developed to analyze the starting condition and steady state operating condition of the lamp. For the prototype ballast for a 250W Metal Halide Lamp, experimental results are presented in order to validate the proposed method.

Lighting Control of High Pressure Discharge Lamp with High Frequency Source (고압 방전등의 고주파 점등 제어)

  • 이치환
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.114-118
    • /
    • 1999
  • This paper shows a structure for an electronic ballast of HID lamps. An electronic ballast for HID lamps usually employs a high-frequency resonant inverter and voltage-to-frequency converter to control the output. A half-bridge and series resonant circuit are chosen for the ballast. The inverter with V/F converter is modeled with a transfer function and a self-feedback controller is proposed. This structure is analyzed and the feedback gain is determined by using the inverter model. Experimental system is built with a commercial 250W high pressure sodium lamp and the results show a validity of the proposed ballast.

  • PDF

Characteristic Analysis of Reactive-Power Compensator using Resonant Current-Source Inverter by simplification model (축소모형에 의한 공진형 전류원 인버터식 무효전력보상기의 특성 분석)

  • 한병문;백승택;박덕희;소용철
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.269-274
    • /
    • 1998
  • This paper describes a scaled model for PWM thyristor current-source inverter with a commutation circuit. The system consists of a 6-pulse thyristor bridge and an LC resonant circuit with thyristor switches, which offers thyristors to have turn-off capability for PWM operation with minimal switching losses. The proposed system can be used as a reactive power compensator with PWM operation for the utilitity application. There would be two advantages in the proposed system over the existing voltage source inverter. One is the low system cost due to using the conventional thyristors. Another is easy expansion of system operation voltage because th series operation of thyristor devices is already proven in HVDC system.

  • PDF

A Study on the High-Frequency Resonant Inverter System for Indirect Induction Heating (간접유도가열용 고주파 공진형 인버터 시스템에 관한 연구)

  • Kwon H. M.;Shin D. C.;Kim K. H.;Kim Y. J.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.322-325
    • /
    • 2002
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20kHz to 50kHz. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted Into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

A Study on the Development of a Power Supply for Driving Magnetron (마그네트론 구동용 전원장치 설계에 관한 연구)

  • 김일권;한주섭;조성훈;이성근;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.744-748
    • /
    • 2002
  • This paper describes a power supply of a CW magnetron for driving a electrodeless plasma lamp. The proposed power supply consists of a power factor controller, a series resonant ZVS half bridge inverter, a high voltage leakage transformer, and two IGBT drives. From the simulation results, it was confirmed that the proposed circuits can control the input power of the magnetron up to 33.3[%] linearly by adjust driving frequency of the inverter.

  • PDF