• 제목/요약/키워드: Series harmonic resonance

검색결과 17건 처리시간 0.028초

하드디스크 드라이브용 압전형 마이크로 액추에이터의 비선형 진동 특성 (Nonlinear Vibrations of Piezoelectric Microactuators in Hard Disk Drives)

  • 정덕영;이승엽;김철순
    • 대한기계학회논문집A
    • /
    • 제25권12호
    • /
    • pp.2002-2008
    • /
    • 2001
  • Nonlinear vibration characteristics of a piezoelectric-type micro actuator used for hard disk drives are experimentally studied. The nonlinear characterisitics include hysteresis, superharmonic resonance, jump phenomenon, and shifting of natural frequencies. The vibration modes and frequencies of the commercial actuator of the Hutchinson's Magnum series are measured using a laser vibrometer. From harmonic excitation to the PZT acturator, we observe interesting hysteresis patterns with 3 times input frequency. It is shown that the micro actuator has the typical 3 times superhamonic resonances coupled to the first torsional and sway modes of the suspension.

계통연계형 인버터의 고조파 전류저감을 위한 LLCL 필터에 관한 연구 (A Study on LLCL Filter to Reduce Harmonic Current of Grid Connected Power Inverter)

  • 안병웅;홍창표;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.64-70
    • /
    • 2014
  • In this paper, the new LLCL filter is proposed for grid connected three-phase PWM inverter for passive damping. LLCL filter inserts a small inductor in the branch of the capacitor of the traditional LCL filter to compose a series resonant circuit to reduce the switching-frequency component on grid current. Using LLCL filter, the switching-frequency current ripple components can be attenuated much better than the LCL filter, leading to a decrease in the total inductance. However, the resonance phenomena caused by zero impedance from the addition of LC branch in LLCL filter can be a big problem. Resonance phenomena of LLCL filter can be a source of grid system instability, so proper damping methods are required. However, it is difficult to apply a passive damping method in the conventional LLCL filter, because the damping resistor increase impedance of the LC branch. Therefore, switching frequency component of grid current can not much attenuated by low Q of LC series resonance effect. In this paper, a new LLCL filter is proposed to overcome the conventional LLCL filter with passive damping. The validity of the proposed method is proven by simulation and experimental result.

상하 결합 마이크로스트립 공진기를 이용한 광대역 저 위상 잡음 전압제어발진기 (Wideband and tow Phase Noise Voltage Controlled Oscillator Using a Broadside Coupled Microstrip Resonator)

  • 문성모;이문규
    • 한국ITS학회 논문지
    • /
    • 제8권4호
    • /
    • pp.46-52
    • /
    • 2009
  • 본 논문에서는 낮은 위상잡음 특성과 넓은 주파수 가변을 갖는 새로운 전압제어 발진기의 구조를 제안한다. 제한한 구조는 서셉턴스 기울기 파라미터를 높이기 위해 임피던스 변환기를 이용하여 직렬 공진 회로를 병렬 공진 회로로 변환하는 방법을 사용하고 있다. 제작한 전압제어발진기는 0V$\sim$9V 가변전압으로 10.1GHz$\sim$10.7GHz의 600MHz 주파수 가변과 -119dBc/Hz@1MHz 이하의 우수한 위상잡음 특성을 보인다. 측정된 고조파 억압특성은 28dB이상이다.

  • PDF

고차 전이함수를 이용한 해양구조물 거동의 비선형도 결정 (Determination of the Degree of Nonlinearity in the Response of Offshore Structures Using Higher Order Transfer Functions)

  • 백인열
    • 한국해안해양공학회지
    • /
    • 제7권1호
    • /
    • pp.116-125
    • /
    • 1995
  • 파하중과 해류하중을 받는 단일 자유도계를 동적 해석하여 비선형 거동을 나타냄을 보이고 고차의 비선형 전이함수를 포함한 모델을 적용하여 그 비선형 차수를 알아낸다. 먼저 구조물에 단일 정현파, 두 파의 합성파 그리고 불규칙파 하중을 차례로 가하면서 각 하중조건마다 세가지 비선형 요인의 효과를 조사한다. 이로부터 단일 자유도계의 공진주파수에서 파의 에너지는 존재하지 않지만 비선형 요인에 의해 응답 성분이 나타남을 보인다. 다음으로 Volterra 급수에 근거한 고차 전이함수(higher order transfer function)모델을 적용하여 유연한 단일 자유도계의 비선형 거동이 성공적으로 모델화됨을 보이며 또한 비선형성이 2차나 3차로 명백히 나타남을 보인다.

  • PDF

마이크로컴퓨터를 이용(利用)한 엔진 성능시험(性能試験)의 자동화(自動化)에 관한 연구(硏究)(II) -모의(模擬) 부하시험(負荷試験) 시스템의 구성(構成) 및 평가(評價)- (A Microcomputer-Based Data Acquisition/Control System for Engine Performance Test(II) -Construction and Evaluation of a Load Simulation System-)

  • 류관희;배영환;윤기직
    • Journal of Biosystems Engineering
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 1989
  • This study was carried out to develop a system and methodology to simulate the engine load variation occuring during agricultural field operations for a laboratory engine test. The system consisted of an electric dynamometer, an Apple II microcomputer, and a data acquisition and control system. Several pieces of instruments were utilized to measure various engine performance data. Both engine torque and engine speed were fully controlled by a computer program. The dynamic characteristics of the system were analyzed through a series of tests and the limitations on the load simulation test were presented. The results of the study are summarized as follows: 1. Engine speed and toque were controlled by a computer program. The use of a stepping motor and reduction gears enabled engine speed be controlled within 1 rpm. 2. The natural frequency of the dynamometer-engine system was found to be around 5 Hz, at which the load simulation would be impossible because of resonance. 3. For the harmonic inputs with the frequencies above the natural frequency, the signal attenuated too much and therefore the load simulation was impossible. 4. The step response of the system showed an overshoot of 24.5 percent and the settling time for 5 percent criterion was around 3 seconds. 5. When actual field test data are utilized for load simulation, a low-pass filter should be included to attenuate the frequency components around and above the natural frequency.

  • PDF

Experimental study on a new damping device for mitigation of structural vibrations under harmonic excitation

  • Alih, Sophia C.;Vafaei, Mohammadreza;Ismail, Nufail;Pabarja, Ali
    • Earthquakes and Structures
    • /
    • 제14권6호
    • /
    • pp.567-576
    • /
    • 2018
  • This manuscript introduces a new damping device which is composed of a water tank and a pendulum. The new damping device can be tuned to multiple frequencies. In addition, it has a higher energy dissipation capacity when compared with the conventional Tuned Liquid Dampers (TLDs). In order to evaluate the efficiency of this new damping device a series of free vibration and forced vibration tests were conducted on a scaled down single-story one-bay steel frame. Two different configurations were studied for the mass of the pendulum that included a completely and a partially submerged mass. It was observed that the completely submerged configuration led to 44% higher damping ratio when compared with the conventional TLD. In addition, the completely submerged configuration reduced the peak displacement response of the structure 1.6 times more than the conventional TLD. The peak acceleration response of the structure equipped with the new damping device was reduced twice more than the conventional TLD. It was also found that, when the excitation frequency is lower than the resonance frequency, the conventional TLD performs better than the partially submerged configuration of the new damping device.

전기철도 AT 급전시스템에서의 TSC-SVC를 이용한 전압강하 보상 (Compensation of Voltage Drop Using the TSC-SVC in Electric Railway Power Supply System)

  • 정현수;방성원;김진오
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.29-36
    • /
    • 2002
  • 최근 들어 국내 전기철도가 고속 대용량화되고 새로운 전력반도체 기술이 전력변환장치에 채용되면서 이로 인해 AT급전계통에 전압강하 등 전력품질 문제가 대두되고 있다. 지금까지 급전계통의 전압강하 대책으로는 직렬콘덴서(SC)를 주로 설치/운용하였으나 기술적인 한계로 인해 충분한 효과를 달성하지 못하고 있으며 고조파 공진현상도 새롭게 문제시 되고 있다. 또한 신규 전기철도 건설에 따른 전철변전소 위치확보 문제와 운행선로에서의 수송량 증가에 따른 열차 증량편성 및 시격(열차운행시간 간격)단축으로 인한 부하 중대가 예상되고 있으며, 급전사고로 인한 인근 전철변전소로부터의 연장급전 운용 등도 고려해야 하므로 이에 따른 급전시스템의 전압강하 및 전력품질 보상 대책이 요구되고 있다. 따라서 본 논문에서는 효과적인 보상대책 설비의 하나로 TSC방식 SVC를 전기철도의 AT 급전시스템에 적용하는 방안을 검토하고 PSCAD/EMTDC를 이용하여 시뮬레이션을 통해 확인하였다.