• 제목/요약/키워드: Series harmonic resonance

검색결과 17건 처리시간 0.029초

Resonance Characteristics Analysis of Grid-connected Inverter Systems based on Sensitivity Theory

  • Wu, Jian;Han, Wanqin;Chen, Tao;Zhao, Jiaqi;Li, Binbin;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.746-756
    • /
    • 2018
  • Harmonic resonance exists in grid-connected inverter systems. In order to determine the network components that contribute to harmonic resonance and the composition of the resonant circuit, sensitivity theory is applied to the resonance characteristic analysis. Based on the modal analysis, the theory of sensitivity is applied to derive a formula for determining the sensitivities of each network component parameter under a resonance circumstance that reflects the participation of the network component. The solving formula is derived for both parallel harmonic resonance and series harmonic resonance. This formula is adopted to a 4-node grid-connected test system. The analysis results reveal that for a certain frequency, the participation of parallel resonance and series resonance are not the same. Finally, experimental results demonstrate that the solving formula for sensitivity is feasible for grid-connected systems.

A High Gain and High Harmonic Rejection LNA Using High Q Series Resonance Technique for SDR Receiver

  • Kim, Byungjoon;Kim, Duksoo;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • 제14권2호
    • /
    • pp.47-53
    • /
    • 2014
  • This paper presents a high gain and high harmonic rejection low-noise amplifier (LNA) for software-defined radio receiver. This LNA exploits the high quality factor (Q) series resonance technique. High Q series resonance can amplify the in-band signal voltage and attenuate the out-band signals. This is achieved by a source impedance transformation. This technique does not consume power and can easily support multiband operation. The chip is fabricated in a $0.13-{\mu}m$ CMOS. It supports four bands (640, 710, 830, and 1,070MHz). The measured forward gain ($S_{21}$) is between 12.1 and 17.4 dB and the noise figure is between 2.7 and 3.3 dB. The IIP3 measures between -5.7 and -10.8 dBm, and the third harmonic rejection ratios are more than 30 dB. The LNA consumes 9.6 mW from a 1.2-V supply.

고조파 전류원에 의한 콘덴서 임피던스 특성 해석 (Analysis of Impedance Performance for Condenser by Harmonic Current Source)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

전력용 커패시터의 전기적 스트레스 해석 (Analysis for Electrical Stress of Power Capacitor)

  • 김종겸;박영진;이은웅;이동주
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.370-376
    • /
    • 2008
  • Power capacitors is widely used for power factor correction and component of passive filter in the user power systems. Recently, application of non-linear load is gradually increased. Non-linear load produces harmonic components of current. There are series resonance and parallel resonance when capacitors are applied in the user electrical application. If this harmonic component matches resonance, voltage and current is magnified and has severely an influences on capacitor. This paper purposes a new method for the magnitude of voltage and current by the frequency scan analysis without equivalent circuit for the actual circuit at the resonance condition.

Resonance Investigation and Active Damping Method for VSC-HVDC Transmission Systems under Unbalanced Faults

  • Tang, Xin;Zhan, Ruoshui;Xi, Yanhui;Xu, Xianyong
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1467-1476
    • /
    • 2019
  • Grid unbalanced faults can cause core saturation of power transformer and produce lower-order harmonics. These issues increase the electrical stress of power electronic devices and can cause a tripping of an entire HVDC system. In this paper, based on the positive-sequence and negative-sequence impedance model of a VSC-HVDC system as seen from the point of common connection (PCC), the resonance problem is analyzed and the factors determining the resonant frequency are obtained. Furthermore, to suppress over-voltage and over-current during resonance, a novel method using a virtual harmonic resistor is proposed. The virtual harmonic resistor emulates the role of a resistor connected in series with the commutating inductor without influencing the active and reactive power control. Simulation results in PSCAD/EMTDC show that the proposed control strategy can suppress resonant over-voltage and over-current. In addition, it can be seen that the proposed strategy improves the safety of the VSC-HVDC system under unbalanced faults.

오차의 허용범위를 고려한 수동형 필터의 특성 해석 (Performance Analysis for Passive Filter Considering Allowable Limits of Tolerance)

  • 김종겸;김일증
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.38-43
    • /
    • 2009
  • Reactors are connected with capacitors to passive filter circuits for reducing harmonics caused by power conversion application. This passive filter frequently gets out of order by voltage and current stress. Especially filter reactor has too much voltage harmonics components, its trouble rate is higher than capacitor. In this paper, we analyzed voltage and current of reactor and capacitor used for passive filter by simulation and measurement. If reactor has a tolerance on variation of reactance value, series resonance frequency is different from originally filter design frequency and parallel resonance can be generated at the close point of the former. Because filter absorbs harmonic component of non-linear load, much of harmonic voltage has been impacted on reactor.

스마트 그리드 배전계통을 위한 직렬 공진형 한류기 적용 방법 및 EMTP-RV 시뮬레이션 연구 (Application Method and EMTP-RV Simulation of Series Resonance Type Fault Current Limiter for Smart Grid based Electrical Power Distribution System)

  • 고윤석;이우철
    • 한국전자통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.361-370
    • /
    • 2024
  • 본 논문에서는 저비용 제작이 가능한 직렬 공진형 한류기를 스마트 그리드 배전 계통에 적용하기 위한 방법을 연구하였다. 먼저, 한류기의 직렬 공진 회로에 주입되는 단락 전류의 고조파 성분들이 과도 응답의 피크 값에 미치는 영향에 대해서 분석하였으며, 퍼센트 임피던스 기반 고장 전류 계산법을 적용하여 정상 상태 응답을 결정하는 방법을 연구하였다. 다음, 시험 배전 선로에 적용하여 채택된 방법의 유효성을 검증하였다. 설계된 한류기를 적용한 시험 배전계통을 EMTP_RV를 이용하여 모델링하였으며 3상 단락 고장 시나리오를 모의하였다. 고장 모의 결과에서 한류기 적용 후 고장 전류의 정상 상태 응답이 설계 목표 값을 정확하게 추종하는 것을 확인하였다. 또한 한류기 적용 전과 후의 고장전류 파형 비교에서 고장 전류가 크게 억제되는 것을 확인함으로써 배전 계통에 대한 직렬 공진형 한류기 적용 효과를 확인할 수 있었다.

Active Nonlinear Vibration Absorber for a Nonlinear System with a Time Delay Acceleration Feedback under the Internal Resonance, Subharmonic, Superharmonic and Principal Parametric Resonance Conditions Simultaneously

  • Mohanty, S;Dwivedy, SK
    • 항공우주시스템공학회지
    • /
    • 제13권5호
    • /
    • pp.9-15
    • /
    • 2019
  • In this paper, dynamic analysis of a nonlinear active vibration absorber is conducted with a time delay acceleration feedback to suppress the vibration of a nonlinear single degree of freedom primary system. The primary system consisting of linear and nonlinear cubic springs, mass, and damper is subjected to the multi-harmonic hard excitation with a parametric excitation. It is proposed to reduce the vibration of the primary system and the absorber by using a lead zirconate titanate (PZT) stack actuator in series with a spring in the absorber which configures as an active vibration absorber. The method of multiple scales (MMS) is used to obtain the approximate solution of the system under the internal resonance, subharmonic, superharmonic, and principal parametric resonance conditions simultaneously. Frequency and time responses of the system are investigated considering a delay in the feedback for the various parameters of the absorber configuration and controlling force.

고조파 수동필터의 설계 및 적용 (Design and Application of Harmonic Passive Filter)

  • 전정채;김재현;유재근
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5397-5402
    • /
    • 2012
  • 고조파와 관련한 전력품질저하로 발생하는 전기설비사고 및 경제적 손실은 증가하고 있다. 수동필터는 고조파 문제를 해결하는데 경제적이고 효과적이지만 많은 엔지니어들은 그들의 전력시스템과의 직병렬 공진 문제 및 고조파 증폭 문제로 인해 사용하기를 꺼려한다. 본 논문은 수동필터가 잘 설계될 경우 고조파 문제를 해결하는데 매우 유용하다는 것을 보여준다. 고조파 수동필터 설계의 방법과 과정을 서술하였다. 그리고 100HP DC 모터, 압출 기계, 에어 압력기 등과 같은 비선형 부하로 인해 고조파 문제를 갖는 계통에 적용할 수 있는 수동필터를 설계하였다. 제시된 설계 방법과 절차에 대한 검증을 실험을 통해 입증하였다.

SC 전용 보호계전기 개발 (Research for Protection Relay of Static Condenser Bank)

  • 정재기;윤시영;김석중;김근규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.48-50
    • /
    • 2006
  • SC(Static Condenser) in KEPCO is used in voltage control and power factor compensation. Currently KEPCO uses SC to 154kv 50MVA and 23kv SMVA. It is not important in old days because a SC bank accident has no effect on power system. But we are interested in the SC bank for power quality in these days. The SC Bank has a reactor and a condenser using series connection. It is operated in critical point for resonance circuit normally. Therefore the SC bank has a small reliability against other Power instruments. If a 4th harmonic frequency as a resonance frequency is supplied in system, the condenser is damaged because of a resonance current. And a trip and a closing for CB(Circuit Breaker) in many times will have a big influence of SC bank destruction. General OCR(Over Current Relay) observing SC bank is not useful for this protection We think that protection relay must be have the SC bank characteristics. A solution for this problem is active Power, resonance frequency and impedance.

  • PDF