• 제목/요약/키워드: Series Operation

검색결과 1,271건 처리시간 0.034초

지적측량업무 영향요인 분석을 통한 수요예측모형 연구 (A Study on Demanding forecasting Model of a Cadastral Surveying Operation by analyzing its primary factors)

  • 송명숙
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2007년도 추계학술대회 및 정기총회
    • /
    • pp.477-481
    • /
    • 2007
  • The purpose of this study is to provide the ideal forecasting model of cadastral survey work load through the Economeatric Analysis of Time Series, Granger Causality and VAR Model Analysis, it suggested the forecasting reference materials for the total amount of cadastral survey general work load. The main result is that the derive of the environment variables which affect cadastral survey general work load and the outcome of VAR(vector auto regression) analysis materials(impulse response function and forecast error variance decomposition analysis materials), which explain the change of general work load depending on altering the environment variables. And also, For confirming the stability of time series data, we took a unit root test, ADF(Augmented Dickey-Fuller) analysis and the time series model analysis derives the best cadastral forecasting model regarding on general cadastral survey work load. And also, it showed up the various standards that are applied the statistical method of econometric analysis so it enhanced the prior aggregate system of cadastral survey work load forecasting.

  • PDF

반도체 스위치 기반 고반복 펄스전원 (High Repetitive Pulsed Power Supply Based on Semi-Conductor Switches)

  • 장성록;안석호;류홍제;김종수;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1023_1024
    • /
    • 2009
  • In this paper, a novel 10kV, 50A, 50kHz pulsed power supply based on IGBT stacks is proposed. Proposed scheme consists of series connected 12 IGBT to generate maximum 10kV output pulse and 10kW full bridge phase-shifted zero voltage switching converter to charge DC capacitor voltage. Each IGBTs are sustain the 830V of capacitor voltage at turn off interval. By turn on the each IGBT for the same time it gives the path for the series connection of charged capacitor. From above turn on and off procedure, high voltage repetitive pulse is applied to the load. The synchronization of gating signal is important of series operation of IGBTs. For gating signal synchronization, specially designed gate power circuit using full bridge inverter and pulse transformer is developed to generate IGBT gating signal.

  • PDF

컴퓨터 부하의 직렬 동조 필터 적용에 의한 고조파 및 순간전압강하 영향에 관한 연구 (A Study on the Harmonics and Voltage Sags Effect by the Series Resonant Filter Application for Personal Computer Loads)

  • 서범관;김경철;이근준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.460-461
    • /
    • 2006
  • Computer Loads can be found in all of modern society. The switching mode power supplies used in personal computers are major sources of harmonic currents. Harmonic currents can cause lots of harmonic problems such as disruption in computer performance. A series resonant filter is very effective in harmonic reduction for personal computer loads. Voltage sags are short duration reductions in rms voltage. The main causes of voltage sags are faults, motor starting, and transformer energizing. Personal computers are another example of devices sensitive to voltage sags. A serious voltage sag at the terminals way lead mis-operation of the equipment. This paper presents an in depth analysis to evaluate the effect of harmonics reduction based on the IEC 61000-3-2 and the effect of voltage sag using ITI curve by applying a series resonant filter for personal computer loads.

  • PDF

Mitigation of Sub-synchronous Oscillation Caused by Thyristor Controlled Series Capacitor Using Supplementary Excitation Damping Controller

  • Wu, Xi;Jiang, Ping;Chen, Bo-Lin;Xiong, Hua-Chuan
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.58-63
    • /
    • 2012
  • The Test Signal Method is adopted to analyze the impact of thyristor controlled series capacitor (TCSC) on sub-synchronous oscillation. The results show that the simulation system takes the risk of Sub-synchronous Oscillation (SSO) while the TCSC is operating in the capacitive region. A supplementary excitation damping controller (SEDC) is used to mitigate SSO caused by the TCSC. A new optimization method which is aimed for optimal phase compensation is proposed. This method is realized by using the particle swarm optimization (PSO) algorithm. The simulation results show that the SEDC designed by this method has superior suitability, and that the secure operation scope of the TCSC is greatly increased.

A Novel Control Strategy for Input-Parallel-Output-Series Inverter System

  • Song, Chun-Wei;Zhao, Rong-Xiang;Lin, Wang-Qing;Zeng, Zheng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.85-90
    • /
    • 2012
  • This paper presents a topology structure and control method for an input-parallel-output-series(IPOS) inverter system which is suitable for high input current, high output voltage, and high power applications. In order to ensure the normal operation of the IPOS inverter system, the control method should achieve input current sharing(ICS) and output voltage sharing(OVS) among constituent modules. Through the analysis in this paper, ICS is automatically achieved as long as OVS is controlled. The IPOS inverter system is controlled by a three-loop control system which is composed of an outer common-output voltage loop, inner current loops and voltage sharing loops. Simulation results show that this control strategy can achieve low total harmonic distortion(THD) in the system output voltage, fast dynamic response, and good output voltage sharing performance.

주파수 제어에 의한 직렬 공진형 컨버터의 특성 해석 (The Analysis of a Series Resonant Converter with Frequency Control)

  • 이윤종;김철진
    • 대한전기학회논문지
    • /
    • 제39권6호
    • /
    • pp.557-567
    • /
    • 1990
  • This paper describes the static and dynamic characteristic analysis of the Series Resonant DC to DC Converter with frequency control. The natural commutation of all switch element is realized when the switching frequency is below the resonant frequency of the tank circuit, and the analysis is limited to only this region. For the analysis method, state plane technique is adopted, and each operation mode is defined from normalized switching frequency Fsn. Under this condition, circuit performance is analyzed ideally. The physical characteristics of the series resonant converter is easily grasped by this analysis method with frequency control and this analytical results are directly applicable to the actual converter design. The validity of the analysis is verified by comparing with experimental results and the stability of the converter is confirmed against small variations around the operating point by conventional frequency domain analysis.

  • PDF

시계열 모형을 이용한 단기 풍력 단지 출력 지역 통합 예측에 관한 연구 (A Study on Centralized Wind Power Forecasting Based on Time Series Models)

  • 위영민;이재희
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.918-922
    • /
    • 2016
  • As the number of wind farms operating has increased, the interest of the central unit commitment and dispatch for wind power has increased as well. Wind power forecast is necessary for effective power system management and operation with high wind power penetrations. This paper presents the centralized wind power forecasting method, which is a forecast to combine all wind farms in the area into one, using time series models. Also, this paper proposes a prediction model modified with wind forecast error compensation. To demonstrate the improvement of wind power forecasting accuracy, the proposed method is compared with persistence model and new reference model which are commonly used as reference in wind power forecasting using Jeju Island data. The results of case studies are presented to show the effectiveness of the proposed wind power forecasting method.

콘버어터 직병렬 접속 운전에 관한 연구 (A Study on the Converter Drive by Means of Series and Parallel Connection)

  • Chung, Yon-Tack;Seo, Yong-Soo;Hwang, Lak-Hoon
    • 대한전기학회논문지
    • /
    • 제33권9호
    • /
    • pp.347-354
    • /
    • 1984
  • This paper presents a method of improving the power factor and , the waveform of A.C line currents and the output waveforms of AC to DC fully bridge converter systems which is achieved by connecting CON I.II and CON III.IV in series and parallel. The basic principle of the CON I.II.III.IV's operation is simple and feasibility of thease converter is proved by experiments. CON I and CON III are constructed of natural commutation, CON II and CON IV are constructed of forced commutation. The experimental results show that the power factor and waveform of the source currents and the output waveforms are improved by the method of connecting converter in series and parallel and driving it in I, II, III, IV quadrant.

  • PDF

Drought Monitoring with Indexed Sequential Modeling

  • Kim, Hung-Soo;Yoon, Yong-Nam
    • Korean Journal of Hydrosciences
    • /
    • 제8권
    • /
    • pp.125-136
    • /
    • 1997
  • The simulation techniques of hydrologic data series have develped for the purposes of the design of water resources system, the optimization of reservoir operation, and the design of flood control of reservoir, etc. While the stochastic models are usually used in most analysis of water resources fields for the generation of data sequences, the indexed sequential modeling (ISM) method based on generation of a series of overlapping short-term flow sequences directly from the historical record has been used for the data generation in the western USA since the early of 1980s. It was reported that the reliable results by ISM were obtained in practical applications. In this study, we generate annual inflow series at a location of Hong Cheon Dam site by using ISM method and autoregressive, order-1 model (AR(1)), and estimate the drought characteristics for the comparison aim between ISM and AR(1).

  • PDF

저전력형 반영구적인 갈바니 전원장치 개발 (The Development of the Low Power Consumption and Long Life Battery using a Galvanic Series)

  • 배정효;김대경;하태현;이현구;최상봉;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3201-3204
    • /
    • 2000
  • In general, analog tester or strip chart recorder have been used to measure the corrosion potential of structures such as gas pipelines, oil pipelines, hot water pipelines, power cables etc. Recently, automatic digital data logger substitutes for these manual equipment because using these manual equipments are tedious and time consuming. However, digital data logger also has a shortcoming, that is, short measuring time because of the short lifetime of batteries. Therefore, we developed a long lifetime and low power loss battery taking advantage of galvanic series. In this paper, the results of development for power generator using two metals and DC/DC converter in order to obtain enough voltage for the operation of digital data logger. DC/DC converter operates with 0.5[V]. Its output voltage is 3.5[V] and output current is from 60[mAh] to 1,200[mAh].

  • PDF