• Title/Summary/Keyword: Series Arc Fault

Search Result 29, Processing Time 0.027 seconds

Short-circuit Protection for the Series-Connected Switches in High Voltage Applications

  • Tu Vo, Nguyen Qui;Choi, Hyun-Chul;Lee, Chang-Hee
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1298-1305
    • /
    • 2016
  • This paper presents the development of a short-circuit protection mechanism on a high voltage switch (HVS) board which is built by a series connection of semiconductor switches. The HVS board is able to quickly detect and limit the peak fault current before the signal board triggers off a gate signal. Voltage clamping techniques are used to safely turn off the short-circuit current and to prevent overvoltage of the series-connected switches. The selection method of the main devices and the development of the HVS board are described in detail. Experimental results have demonstrated that the HVS board is capable of withstanding a short-circuit current at a rated voltage of 10kV without a di/dt slowing down inductor. The corresponding short-circuit current is restricted to 125 A within 100 ns and can safely turn off within 120 ns.

K-Ar Age of the Keumseongsan Volcanic Rocks and Mineralization in the Southeastern Part of Euiseong, Gyeongsangbuk-Do, Republic of Korea (경북·의성 동남부에 분포하는 금성산 화산암류의 K-Ar연대와 그주변의 광화시기)

  • Lee, Hyun Koo;Kim, Sang Jung;Yun, Hyesu;Choi, Wyi Chan;Song, Young Su;Itaya, Tetsumaru
    • Economic and Environmental Geology
    • /
    • v.26 no.4
    • /
    • pp.445-454
    • /
    • 1993
  • The Keumseongsan caldera is composed of the Cretaceous sedimentary rocks of the Gyeonesang Supergroup, volcanic rocks of the Yucheon Group and basic dykes. The Keumseongsan caldera is formed by subsidence of volcanic rocks, and arc fault developed late. Also, synistral strike-slip fault ($N60^{\circ}W$) developed. Volcanic rocks belong to subalkaline rocks and calcalkaline magma series. First tuffaceous breccia erupted before 71.4 Ma and cavity of magma chamber caused subsidence, which formed arc fault. Basaltic lava erupted at 71.4 Ma and residual fluids containing Fe, As, Pb, Zn and Cu metal elements built the Ohto deposits, which are dated to be 70.5 Ma based on K-Ar age for sericite. Tuffaceous breccia and tuff erupted between 70.5 and 67 Ma. When volcanic eruption became weakened, cavity in site of magma chamber brought subsidence. Rhyolite intruded and erupted at 67 Ma, and intrusive rhyolite intruded according to arc faults, also. Hydrothermal fluids containing Fe, As, Pb, Zn, Cu, Sb, Bi, Au and Ag formed the Tohyeon deposits. K-Ar age for sericite from the Tohyeon mine gives 66.0 Ma. Results of field exploration, geochemical analyses of volcanic rocks support mineralization possibility by volcanism. Especially, age of volcanism and mineralization are well in coincidence with results of K-Ar age dating. By these results, Ohto Cu mineralization is regarded to be associcated with basaltic rocks, while Tohyeon Cu mineralization with rhyolitic rocks.

  • PDF

Series Arc Wave Analysis and Detection Algorithm (직렬아크 파형 분석 및 검출 알고리즘)

  • Kwon, Wan-Sung;Choi, Su-Kyung;Bang, Sun-Bae;Kim, Chong-Min;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.240-242
    • /
    • 2009
  • 현재 미국에서는 전기화재를 예방하기 위한 AFCI(Arc Fault Circuit Interrupter) 설치가 법으로 제정되어 보급되고 있으며 이에 대한 기준인 UL1699가 제정되어 있다. 본 논문에서는 UL1699의 규정에 기반한 직렬아크발생장치를 통하여 여러 가정용 부하에서 발생시킨 아크의 전류파형들을 주파수영역과 이산 웨이블렛을 이용하여 분석해보고 그에 따른 검출 알고리즘을 제안하고자 한다.

  • PDF

Analysis of Series Arc Fault Current Using Discrete Wavelet Transform (이산 웨이블렛 변환을 이용한 직렬 아크고장전류 분석)

  • Bang, Sun-Bae;Kim, Chong-Min;Park, Chong-Yeun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.318-321
    • /
    • 2009
  • 누전차단기 설치 상태에서도 전기화재가 지속적으로 발생함에 따라 전기화재의 원인이 되는 전기 아크에 대한 관심이 증가하고 있는 실정으로 본 논문에서는 UL1699의 아크 저해시험(inhibition tests)에서 제시하고 있는 직렬 아크코장시험(Arc generator test)을 실시하고, 아크고장전류 분석방법으로 최근에 많이 사용되고 있는 이산 웨이블렛 변환을 이용한 3가지 분석방법에 대하여 아크고장전류 검출 확률을 분석하였다. 분석결과, (1) 근사계수 분석에 의한 최대치 변화율 실효치 변화율 분석방법은 46%의 검출 확률을 얻을 수 있었고, (2) 상세계수 분석에 의한 최대치 변화율 실효치 변화율 분석방법은 62%, (3) 근사계수 분석에 의한 잡음량 변화율 shoulder 변화율 분석방법은 100% 검출 확률을 얻을 수 있었다.

  • PDF

An Accidental Position Detection Algorithm for High-Pressure Equipment using Microphone Array (Microphone Array를 이용한 고압설비의 고장위치인식 알고리즘)

  • Kim, Deuk-Kwon;Han, Sun-Sin;Ha, Hyun-Uk;Lee, Jang-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2300-2307
    • /
    • 2008
  • This study receives the noise transmitted in a constant audio frequency range through a microphone array in which the noise(like grease in a pan) occurs on the power supply line due to the troublesome partial discharge(arc). Then by going through a series of signal processing of removing noise, this study measures the distance and direction up to the noise caused by the troublesome partial discharge(arc) and monitors the result by displaying in the analog and digital method. After these, it determines the state of each size and judges the distance and direction of problematic part. When the signal sound transmitted by the signal source of bad insulator is received on each microphone, the signal comes only in the frequency range of 20 kHz by passing through the circuit of amplification and 6th low pass filter. Then, this signal is entered in a digital value of digital signal processing(TMS320F2812) through the 16-bit A/D conversion. By doing so, the sound distance, direction and coordinate of bad insulator can be detected by realizing the correlation method of detecting the arriving time difference occurring on each microphone and the algorithm of detecting maximum time difference.

Series DC arc fault detection algorithm using time and frequency domain information (시간 및 주파수 영역 정보를 이용한 직렬 DC 아크 고장 검출 알고리즘)

  • Chae, Suyong;Park, Jinju;Park, Sukin;Han, Soobin
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.427-428
    • /
    • 2015
  • 본 논문은 DC 배전시스템 내에서 발생할 수 있는 직렬 DC 아크 고장을 검출하기 위한 알고리즘을 제안한다. 직렬 DC 아크 고장은 동일 전위의 도선 또는 접속점의 노화 등으로 인해 발생하며, 아크 고장 에너지의 크기에 따라 수초 이내에 화재 사고를 유발할 수 있기 때문에 정확한 고장 검출을 통한 빠른 제거가 필요하다. 스위칭 전력변환 장치에서 발생하는 노이즈 성분에 의한 검출 알고리즘의 오동작 현상을 제거하기 위해 시간 영역에서의 전류 변화와 주파수 영역에서의 전류 크기 차이를 동시에 이용하여 직렬 DC 아크 고장 발생여부를 검출하게 된다. 제안 알고리즘은 5kW급 용량의 380V 저전압 DC 배전 시스템을 대상으로 검증하였다.

  • PDF

Series Arc-Fault Characteristics using Wavelet Transform (웨이블렛을 이용한 직렬 아크고장 전압.전류 특성 분석)

  • Bang, Sun-Bae;Shong, Kil-Mok;Choi, Won-Ho;Park, Chong-Yeun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2088-2089
    • /
    • 2007
  • 본 논문은 직렬 아크고장 신호분석과 관련된 연구로서, 정상상태와 아크고장 상태에서 발생하는 전압 전류를 검출하여 아크고장 전류의 특이점을 분석하였다. 역률이 1인 저항성 부하와 L성 부하, C성 부하를 구성하고, 순시 임피던스 분석, FFT 분석, 웨이블렛 분석 방법을 사용하였다. 분석결과 순시 임피던스 분석방법과 FFT 분석방법에서는 직렬 아크고장 신호의 특이점을 찾을 수 있었으나 정량화하기가 어렵고, 웨이블렛 분석방법으로는 직렬 아크고장 신호의 특이점 검출 및 정량화 가능성을 발견할 수 있었다.

  • PDF

DC Series Arc Fault Detector Based on the Discrete Wavelet Transform Algorithm for a Large Photovoltaic System (대용량 PV 시스템 적용을 위한 DWT 알고리즘 기반 태양광 직렬 아크 검출기)

  • Cho, Chan-Gi;Ahn, Jae-Beom;Lee, Jin-Han;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.1-3
    • /
    • 2020
  • 본 논문은 주파수 분석 방법 중 하나인 Discrete Wavelet Transform (DWT)을 활용하여 태양광 직렬 아크 사고를 검출하는 방법에 관하여 다룬다. DWT 알고리즘은 주파수 도메인에서도 시간 축 정보를 표현할 수 있어 기존의 Fast Fourier Transform (FFT) 주파수 분석 알고리즘과 차이점이 있으며, 대용량 태양광 시스템의 직렬 아크 사고 검출에 최적화 되도록 DWT 알고리즘의 속도를 향상시켜 태양광 DC 아크 사고 안전규격인 UL1699B의 요구 조건을 만족시켰다. DWT 알고리즘의 경우 TMS320F28033 기반으로 구현 되었으며 대용량 PV 시스템 적용을 위해 로고스키코일을 전류 센서로 사용하였다. 또한, 모의 DC 직렬 아크 발생 회로를 구축하여 제작한 사고 검출기의 성능을 실제 아크 발생 조건에서 검증하였다.

  • PDF

Geology and Geochemistry of Volcanic and Sedimentary Rocks from Deep Borehole in the Heunghae area, North Kyungsang Province (경북 흥해지역 심부시추공의 화산암 및 퇴적암류의 지질 및 지화학적 연구)

  • Lee, Chang-Bum;Kim, Tong-Kwon;Park, Deok-Won
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.459-474
    • /
    • 2009
  • By the analysis of discontinuity at the outcrop and lineament on the satellite image, the joints have deeply relationship with the lineaments. The joint spaces at the drilling core are mostly 1~20 cm but at the rhyolite which is distributed near fault they have more closely. These volcanic rocks belong to the subalkaline series tuff, rhyolite, basalt in the study area from the diagram of $Nb/Y-Zr/TiO_2$. The composition diagram of Hf/3-Th-Nb/16 show destructive plate-margin basalt and their differentiates. The environment of formation of volcanics are normal continental arc. Most of LREE show high enriched pattern but HREE show depleted pattern. The K/Ar age of intermediate volcanics, tuff, rhyolite, crystal tuff are 55.3Ma, 77.25 Ma~91.22Ma, 63.16~64.39Ma, 54.49 Ma respectively.