• 제목/요약/키워드: Serial test

검색결과 346건 처리시간 0.023초

A Spread Spectrum Clock Generator for SATA II with Rounded Hershey-Kiss Modulation Profile

  • Moon, Yong-Hwan;Lim, Wan-Sik;Kim, Tae-Ho;Kang, Jin-Ku
    • 전기전자학회논문지
    • /
    • 제15권2호
    • /
    • pp.129-133
    • /
    • 2011
  • A spread spectrum clock generation is an efficient way to reduce electro-magnetic interference (EMI) radiation in modern mixed signal chip systems. The proposed circuit generates the spread spectrum clock by directly injecting the modulation voltage into the voltage-controlled oscillator (VCO) current source for SATA II. The resulting 33KHz modulation profile has a Hersey-Kiss shape with a rounded peak. The chip has been fabricated using $0.18{\mu}m$ CMOS process and test results show that the proposed circuit achieves 0.509% (5090ppm) down spreading at 1.5GHz and peak power reduction of 10dB. The active chip area is 0.36mm ${\times}$ 0.49mm and the chip consumes 30mW power at 1.5GHz.

Reliable and Secure Voice Encryption over GSM Voice Channel

  • Lee, Hoon-Jae;Jang, Won-Tae;Kim, Tae-Yong
    • Journal of information and communication convergence engineering
    • /
    • 제8권1호
    • /
    • pp.64-70
    • /
    • 2010
  • In this paper, we study and develope a special secure Dongle to be adapted in GSM SmartPhone for secure voice communication to the serial 20-pin connector in SmartPhone. We design and implement the Dongle module hardware, firmware, and software including cipher crypto-synchronization and cipher algorithm. Also we study and emulate the SmartPhone GUI software interface including communication software module to the Dongle. Finally, we analyze the performances of crypto-synchronization in some noisy environment and also we test the secure Dongle module.

모델휴먼프로세서를 활용한 인지과정 시뮬레이터 구축에 관한 연구 (A Study on Development of a Cognitive Process Simulator Based on Model Human Processor)

  • 이동하;나윤균
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.230-239
    • /
    • 1998
  • Though limited, Model Human Processor (MHP) has been used to explain the complex users' behaviors during human-computer interactions in a simplified manner. MHP consists of perceptual, cognitive and motor systems, each with processors and memories interacting with each other in serial or parallel mode. The important parameters of memory include the storage capacity, the decay time, and the code type of a memorized item. The important parameter of a processor is the cycle time. Using these features of the model, this study developed a computerized cognitive process simulator to predict the cognitive process time of a class match task process. An experimental validity test result showed that the mean prediction time for cognitive process of the class match task simulated 50 times by the simulator was consistent with the mean cognitive process time of the same task performed by 37 subjects. Animation of the data flow during the class match task simulation will help understand the invisible human cognitive process.

  • PDF

USB IF를 이용한 GUI환경의 제어기 개발 (GUI Environmental Controller Design with USB IF)

  • Sun-Hag Hong
    • 한국컴퓨터산업학회논문지
    • /
    • 제4권4호
    • /
    • pp.449-454
    • /
    • 2003
  • 본 논문에서는 USB 인터페이스를 이용한 GU 환경의 제어기를 구현해 보였다. 특히, 프론트 판넬에 취부된 외부 USB 포트의 성능 검사는 비쥬얼 C++ 검사 프로그램을 사용하여 자동적으로 실행되도록 하였다. 성능검사 프로그램은 실험 결과를 가청적 또는 가시적으로 표시함으로서 작업자의 조작을 최소화하고, 생산성을 최대화할 수 있도록 하였다. GUI 환경의 제어기는 검사 프로그램을 사용하여 표준방식 키보드, 트랙볼. 엔코더, 아날로그 퍼텐시오미터, 2개의 디스플레이장치 및 터치스크린을 제어 할 수 있다.

  • PDF

ELIMINATION PATTERNS OF ARTERIAL BLOOD CYANIDE ION IN THIOSULFATE-OXYGEN ADMINISTERED RABBIT

  • Yoo, Keun-Young;Lee, Yoon-Seong;Yun, Dork-Ro
    • Toxicological Research
    • /
    • 제3권2호
    • /
    • pp.89-96
    • /
    • 1987
  • To test the efficacies of thiosulfate in cyanide poisoning with or without oxygen, after the administration of sublethal dose of potassium cyanide, serial arterial blood samples were collected during 60 minutes in 15 rabbits. Cyanide ion concentrations were measured by Conway cell microdiffusion method, and arterial oxygen tensions were also observed. Comparison of elimination constants showed that arterial blood cyanide ion concentration decreased most rapidly in the thiosulfate with oxygen-administered group. The elimination of cyanide ion by the action of thiosulfate in acutely poisoned rabbit accelerated probably due to oxygen and elimination pattern seems to occur by first-order elimination kinetics.

  • PDF

공공교통 전동차 안전운행을 위한 RIMS 프로젝트 적용의 성공요인 연구 (A Study on the Successful Factors in the Application of RIMS Project for the Safe Operation of Rolling Stocks in the Public Transportation)

  • 이강원;방연근;손영진
    • 한국철도학회논문집
    • /
    • 제9권5호
    • /
    • pp.555-560
    • /
    • 2006
  • This study finds out and suggests success factors for the application of RIMS project through the case study of Seoul Metro and literature survey. The successful application of RIMS needs expert knowledge and concept of BOM, standardization of maintenance planning, check lists of heavy maintenance inspection, organization structure of rolling stock maintenance offices, material management system of warehousing and the process of parts repairing between offices, connection of material ordering system, problem solving of circular spare parts administration among inspection, maintenance, and material organizational units, systemic serial number management of parts with RFID, daily closing diary connected with work process chart, and sufficient period of RIMS's test run. RIMS contributes to real time management of rolling stock maintenance, transparency of management, reliability of train operation, customer satisfaction, and management innovation.

Bootstrap 방법을 이용한 결합 Shewhart-CUSUM 관리도의 설계 (Design of Combined Shewhart-CUSUM Control Chart using Bootstrap Method)

  • 송서일;조영찬;박현규
    • 산업경영시스템학회지
    • /
    • 제25권4호
    • /
    • pp.1-7
    • /
    • 2002
  • Statistical process control is used widely as an effective tool to solve the quality problems in practice fields. All the control charts used in statistical process control are parametric methods, suppose that the process distributes normal and observations are independent. But these assumptions, practically, are often violated if the test of normality of the observations is rejected and/or the serial correlation is existed within observed data. Thus, in this study, to screening process, the Combined Shewhart - CUSUM quality control chart is described and evaluated that used bootstrap method. In this scheme the CUSUM chart will quickly detect small shifts form the goal while the addition of Shewhart limits increases the speed of detecting large shifts. Therefor, the CSC control chart is detected both small and large shifts in process, and the simulation results for its performance are exhibited. The bootstrap CSC control chart proposed in this paper is superior to the standard method for both normal and skewed distribution, and brings in terms of ARL to the same result.

Optimal Designs of Partially Constant-Stress Life Testing For Three-Component Mixed Systems

  • Park, Hee-Chang;Jeng, Kwang-Man;Kim, Min-Hwan
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 한국데이터정보과학회 2002년도 춘계학술대회
    • /
    • pp.155-167
    • /
    • 2002
  • In this paper we consider optimal designs of partially constant-stress life testing which is deviced for three-component mixed systems with the considerably long time. Mixed systems are jointed serial system with parallel system. Test items are run at both use condition and accelerated condition until a specified censoring time. The optimal criterion for the sample-proportion allocated to accelerated condition is to minimized asymptotic variance of the maximum likelihood estimators of the acceleration factor and hazard rates.

  • PDF

4 채널의 Photo-plethysmogram 시스템 구현에 관한 연구(I) (Implementation of 4 Channel Photo-Plethysmogram System(I))

  • 김형태;한순천;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.253-256
    • /
    • 2002
  • In this paper, we implement the volume pulse detection system which can quantitatively represent an artery elasticity. The system consists of transducer which has IRLED-photodiode detecter, temperature sensor, filters, preprocessing circuits, A/D converter, serial communication part and computer system. In order to presume the artery elasticity information we measure the volume pulse at four points and then evaluate the transition time, distance and the correlation coefficient of the pulse wave between the points. We test the system with 10 subjects during the week for basic experiment and obtain the data at four points. As the result of experiment, we can detect normalized volume pulse wave and evaluated parameter with effectively.

  • PDF

급성 벨마비와 동시에 발생한 반대측 반얼굴연축 (Contralateral Hemifacial Spasm Occurred Simultaneously in Acute Bell's Palsy)

  • 이동국
    • Annals of Clinical Neurophysiology
    • /
    • 제7권2호
    • /
    • pp.117-120
    • /
    • 2005
  • Hemifacial spasm (HFS) may develop after Bell's palsy (BP). But it was not reported that contralateral HFS occurred simultaneously in acute BP. A 25-year-old woman admitted with left HFS occurred simultaneously in acute right BP for 6 days. Past, family, and social history were unremarkable. Nerve conduction studies (NCS) and blink reflex (BR) test showed bilateral facial neuropathies. Brain MRI and cerebral angiography were normal. The symptoms and signs of HFS and BP were improved slowly after acyclovir and prednisolone therapy. Follow-up serial NCS and BR also showed a rapid improvement.

  • PDF