A Study on Built-In Self Test for Boards with Multiple Scan Paths (다중 주사 경로 회로 기판을 위한 내장된 자체 테스트 기법의 연구)

  • Kim, Hyun-Jin;Shin, Jong-Chul;Yim, Yong-Tae;Kang, Sung-Ho
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.2
    • /
    • pp.14-25
    • /
    • 1999
  • The IEEE standard 1149.1, which was proposed to increase the observability and the controllability in I/O pins, makes it possible the board level testing. In the boundary-scan environments, many shift operations are required due to their serial nature. This increases the test application time and the test application costs. To reduce the test application time, the method based on the parallel opereational multiple scan paths was proposed, but this requires the additional I/O pins and the internal wires. Moreover, it is difficult to make the designs in conformity to the IEEE standard 1149.1 since the standard does not support the parallel operation of data shifts on the scan paths. In this paper, the multiple scan path access algorithm which controls two scan paths simultaneously with one test bus is proposed. Based on the new algorithm, the new algorithm, the new board level BIST architecture which has a relatively small area overhead is developed. The new BIST architecture can reduce the test application time since it can shift the test patterns and the test responses of two scan paths at a time. In addition, it can reduce the costs for the test pattern generation and the test response analysis.

  • PDF

A Highly Expandable Forwarded-Clock Receiver with Ultra-Slim Data Lane using Skew Calibration by Multi-Phase Edge Monitoring

  • Yoo, Byoung-Joo;Song, Ho-Young;Chi, Han-Kyu;Bae, Woo-Rham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.433-448
    • /
    • 2012
  • A source-synchronous receiver based on a delay-locked loop is presented. It employs a shared global calibration control between channels, yet achieves channel expandability for high aggregate I/O bandwidth. The global calibration control accomplishes skew calibration, equalizer adaptation, and phase lock of all the channels in a calibration period, resulting in the reduced hardware overhead and area of each data lane. In addition, the weight-adjusted dual-interpolating delay cell, which is used in the multiphase DLL, guarantees sufficient phase linearity without using dummy delay cells, while offering a high-frequency operation. The proposed receiver is designed in the 90-nm CMOS technology, and achieves error-free eye openings of more than 0.5 UI across 9-28 inch Nelco4000-6 microstrips at 4-7 Gb/s and more than 0.42 UI at data rates of up to 9 Gb/s. The data lane occupies only $0.152mm^2$ and consumes 69.8 mW, while the rest of the receiver occupies $0.297mm^2$ and consumes 56.0 mW at the 7- Gb/s data-rate and supply voltage of 1.35 V.

Effect of Food on Pharmacokinetics and Pharmacodynamics of Fenofibric Acid after a Single Oral Dose of Fenofibrate Sustained-Release Capsule (식단에 따르는 페노피브레이트 서방성 캡슐의 1회 경구 투여 후 약물동태학 및 약물동력학의 평가)

  • Yun, Hwi-yeol;Kim, Joung-hyun;Lee, Eun Joo;Chung, Soo Youn;Choi, Sun-oK;Kim, Hyung Kee;Kwon, Jun-tack;Kang, Wonku;Kwon, Kwang-il
    • Korean Journal of Clinical Pharmacy
    • /
    • v.15 no.1
    • /
    • pp.34-40
    • /
    • 2005
  • We examined the effects of food on pharmacokinetic and pharmacodynamic properties of fenofibrate released from sustained-release(SR) capsule as therapy for hypolipidemia. Twenty-four healthy volunteers were used in $3{\times}3$ crossover pharmacokinetic and pharmacodynamic study; Additional six volunteers were used as a control group (i.e., no fenofibrate administration). A single dose of fenofibrate (SR capsule, 250 mg) was administered on three occasions: after overnight fasting, after consumption of a standard breakfast, and after a high-fat breakfast. Serial blood samples were collected for the next 72 hours. Plasma fenofibric acid concentrations were measured by high performance liquid chromatography, and pharmacokinetic parameters were calculated using ADAPT II program. Plsama triglyceride concentrations were measured by blood chemistry analyzer (CH-100). The pharmacokinetic parameters were significantly affected by food intake. The high-fat breakfast affected the rate of absorption of fenofibrate more than did the standard breakfast and fasted conditions. Plasma concentrations of triglyceride at 24 hours decreased significantly after the administration of fenofibrate compared with the concentration at 0 hours(P<0.05). In healthy volunteers, the bioavailability of fenofibrate was greater when administered via sustained-release capsules immediately after the consumption of food than after fasting condition.

  • PDF

LAPG-2: A Cost-Efficient Design Verification Platform with Virtual Logic Analyzer and Pattern Generator (LAPG-2: 가상 논리 분석기 및 패턴 생성기를 갖는 저비용 설계 검증 플랫폼)

  • Hwang, Soo-Yun;Kang, Dong-Soo;Jhang, Kyoung-Son;Yi, Kang
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.35 no.5
    • /
    • pp.231-236
    • /
    • 2008
  • This paper proposes a cost-efficient and flexible FPGA-based logic circuit emulation platform. By improving the performance and adding more features, this new platform is an enhanced version of our LAPG. It consists of an FPGA-based hardware engine and software element to drive the emulation and monitor the results. It also provides an interactive verification environment which uses an efficient communication protocol through a bi-directional serial link between the host and the FPGA board. The experimental results show that this new approach saves $55%{\sim}99%$ of communication overhead compared with other methods. According to the test results, the new LAPG is more area efficient in complex circuits with many I/O ports.

Making USB Wireless For Attaching to the Embedded System (임베디드 시스템 장착을 위한 USB 장치의 무선화)

  • Yoo Jin Ho;Cho Il Yeon;Lee Sang Ho;Han Dong Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.1B
    • /
    • pp.19-25
    • /
    • 2006
  • It's for USB to be used more frequently than another I/O devices. The Universal Serial Bus is the most successful interface in PC history. It's already the do facto interconnect for PCs, and has proliferated into consumer electronics(CE) and mobile devices as well. USB has built on many killer applications, many CE devices, many interfaces. The tangle of wires among the number of devices in your home demands wireless technology. If our devices is unwired, it solves the tangle of wires. In this paper we want to use Legacy USB functionalities, portabilities, multimedia capabilities with wireless interconnection. This paper is related to a study of USB implementation without wires. This paper is related to make the hub function of USB cordless, so it will connect host with devices without wires. In case making USB wireless, it must support the above functionalities. Moreover, It needs the data structure and the resources for host functionalities, e.g. ETD(Endpoint Transfer Descriptor), data memory. This will benefit a convenient use of USB.

Characteristics of superconducting fault current limiters with various pattern shape (초전도 전류제한기의 패턴형상별 특성)

  • Choi, H.S.;Chung, H.S.;Choi, C.J.;Lee, S.I.;Chung, S.B.;Oh, G.K.;Lim, S.H.;Han, B.S.;Chung, D.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.529-532
    • /
    • 2003
  • Quench behavior of resistive superconducting fault current limiters (SFCLs) with various pattern shapes was investigated. The pattern shapes employed were meander, bi-spiral, and spiral shapes of identical line width, gap and margin. SFCLs were fabricated from YBCO thin films grown on two-inch diameter $Al_2O_3$ substrates under the same conditions. Resistance rise of current limiting elements was low at a spiral shape before the whole quench completion, which may act as a disadvantage for simultaneous quench in serial connection between current limiting elements, but the temperature tended to have similar values at higher voltages. On the other hand, bi-spiral shape was severe at insulation level between current limiting lines. When these aspects were considered, we concluded that a meander shape was appropriate to design for a resistive SFCL based on thin films except the concentration of electric field at edge areas of strip lines.

  • PDF

High-speed visible light communication system using space division processing (공간 분할 처리를 이용한 고속 가시광통신 시스템)

  • Park, Jun Hyung;Lee, Kyu Jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.6
    • /
    • pp.237-242
    • /
    • 2018
  • There are various 'wireless communication technologies' around us. Wireless mobile communication has evolved through various stages, and its utilization is also diverse. However, due to the development of wireless communication technology, the demand for frequency resources is much higher than the supply, so frequency shortage is serious. Recently, 'visible light communication' has been attracting attention as an emerging communication technology that can solve the frequency shortage. 'Visible light communication' is a communication method based on serial data transmission / reception, and there is a difficulty in transmitting / receiving parallel data because the transmitter and the receiver are arbitrarily present. In this paper, we have studied parallel data processing of visible light communication. We could solve the problem by analyzing parallel data using image processing. Through this study, communication performance can be verified through I / O data comparison by implementing parallel data analysis method. It is expected that diversity in parallel data analysis will be presented through the results.

Expression of Sodium/iodide Symporter Transgene in Neural Stem Cells (신경줄기세포(HB1.F3)에서 나트륨옥소 공동수송체 도입유전자 발현)

  • Kim, Yun-Hui;Lee, Dong-Soo;Kang, Joo-Hyun;Lee, Yong-Jin;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.99-108
    • /
    • 2004
  • Purpose: The ability to noninvasively track the migration of neural progenitor cells would have significant clinical and research implications. We generated stably transfected F3 human neural progenitor cells with human sodium/iodide symporter (hNIS) for noninvasively tracking F3. In this study, the expression patterns of hNIS gene in F3-NIS were examined according to the cultured time and the epigenetic modulation. Materials and Methods: F3 human neural stem cells had been obtained from Dr. Seung U. Kim (Ajou University, Suwon, Korea). hNIS and hygromycin resistance gene were linked with IRES (Internal Ribosome Entry Site) under control of CMV promoter. This construct was transfected to F3 with Liposome. To investigate the restoration of hNIS gene expression in F3-NIS, cells were treated with demethylating agent (5-Azacytidine) and Histone deacetylase inhibitor (Trichostatin A: TSA). The expression of hNIS was measured by I-125 uptake assay and RT-PCR analysis. Results: The iodide uptake of the F3-NIS was higher 12.86 times than F3 cell line. According to the cell passage number, hNIS expression in F3-NIS gradually diminished. After treatment of 5-Azacytidine and TSA with serial doses (up to $20{\mu}M$, up to 62.5nM, respectively) for 24 hours, I-125 uptake and mRNA of hNIS in F3-NIS were increased. Conclusion: These results suggest that hNIS transfected F3 might undergo a change in its biological characters by cell passage. Therefore, the gene ex[ressopm of exogenous gene transferred human stem cell might be affected to the epigenetic modulation such as promoter methylation and Histone deacetylation and to the cell culture conditions.

A Test of Attentional Blink: Hemifield Independence and Interaction (주의 깜박임 현상의 검증: 주의 자원의 반시야 독립성과 상호작용)

  • Kim, Jung-Yul;Lee, Guk-Hee;Lee, Hyung-Chul O.;Kim, ShinWoo
    • Science of Emotion and Sensibility
    • /
    • v.20 no.2
    • /
    • pp.127-136
    • /
    • 2017
  • Attentional blink is observed in an identification task of multiple targets during rapid serial visual presentation (RSVP) where performance for the second target (T2) that follows within 500ms of the first (T1) shows systematic decrease although that for T1 remains highly accurate. Theories accounting for attentional blink can be classified into two broad categories of resource depletion model and disruption of input filter model. Meanwhile, visual attention capacity shows hemifield independence between left and right visual fields, and many studies reported bilateral advantage in a range of visual working memory tasks. The current research tested two major theories of attentional blink using bilateral independence of attentional capacity. To this end, we conducted two experiments where two RSVPs were presented in either bilateral or unilateral visual fields. Experiment 1 presented two RSVPs which contained both T1 and T2 in either bilateral or unilateral visual fields and tested interaction between attentional blink and bilateral advantage. Experiment 2 removed T1 in one of the two RSVPs to test whether attentional blink obtains when identification of T1 and T2 utilize independent sources of attention across two visual fields. The results showed that subjects were more accurate when two RSVPs were presented in bilateral visual fields (i.e., bilateral advantage) although there was no interaction between attentional blink and bilateral advantage (Experiment 1). In addition, attentional blink for T2 was observed in a T1-absent RSVP even when two RSVPs were presented in bilateral visual fields (Experiment 2). These results support disruption of input filter model rather than resource depletion model.

Highly Sensitive Detection of Pathogenic Bacteria Using PDMS Micro Chip Containing Glass Bead (유리비드를 포함한 PDMS 마이크로칩을 이용한 고감도 감염성 병원균 측정에 관한 연구)

  • Won, Ji-Yeong;Min, Jun-Hong
    • KSBB Journal
    • /
    • v.24 no.5
    • /
    • pp.432-438
    • /
    • 2009
  • Here, we demonstrated simple nucleic acid, RNA, concentration method using polymer micro chip containing glass bead ($100\;{\mu}m$). Polymer micro chip was fabricated by PDMS ($1.5\;cm\;{\times}\;1.5\;cm$, $100\;{\mu}m$ in the height) including pillar structure ($160\;{\mu}m\;(I)\;{\times}\;80\;{\mu}m\;(w)\;{\times}\;100\;{\mu}m\;(h)$, gap size $50\;{\mu}m$) for blocking micro bead. RNA could be adsorbed on micro glass bead at low pH by hydrogen bonding whereas RNA was released at high pH by electrostatic force between silica surface and RNA. Amount of glass beads and flow rate were optimized in aspects of adsorption and desorption of RNA. Adsorption and desorption rate was measured with real time PCR. This concentrated RNA was applied to amplification micro chip in which NASBA (Nucleic Acid Sequence Based Amplification) was performed. As a result, E.coli O157 : H7 in the concentration of 10 c.f.u./10 mL was successfully detected by these serial processes (concentration and amplification) with polymer micro chips. It implies this simple concentration method using polymer micro chip can be directly applied to ultra sensitive method to measure viable bacteria and virus in clinical samples as well as environmental samples.