• Title/Summary/Keyword: Serial/Parallel Connection

Search Result 47, Processing Time 0.025 seconds

A Study Of Parallel Characteristics Of 50[W] Virtual Implement of 50[W]Solar Cell modules Using Droop-Method (Droop Method를 이용한 50[W]급 태양전지 가상구현 시스템의 병렬연결 출력특성에 대한 연구)

  • Lee B.I.;Lee S.Y.;Oh B.W.;Jung B.H.;Choe G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.692-695
    • /
    • 2003
  • Generally, photovoltaic system is composed with several solar cell modules. For increasing power of photovoltaic systems, serial and parallel connection needed. A Desirable characteristic of a parallel supply system is that individual converters share the load current equally and stably. The current sharing(CS) can be implemented using two approaches. The first one, known as a droop method, relies on the high output impedance of each converter. and The second approach, known as active current-sharing techniques. In this paper, using droop method at parallel connection with it's convenience and simplicity.

  • PDF

A Study of Central Data Acquiring by Using Computer Serial Port and Parallel Port (직.병렬 PORT를 이용한 중앙직접 신호취득방식에 관한 연구)

  • Park, Ho-Cheul;Yoon, Woo-Yung;Chun, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.663-665
    • /
    • 1998
  • The measuring data acquisition methods from local sensor are many kinds of techniques. But, if sampling time is not important and we need data of many sensors it is more resonable to be applied economical system. In this paper, the data acquisition technique is used two RS232C communication signals simultaneously. The one come from computer serial port, and another is signal changed from parallel port. In this case the circuits would be simplification and that communication cable is connected by Parallel instead of Branch connection.

  • PDF

The control & measurement of DC/STEP motor device using the computer (PC를 이용한 직류/스탭모터 장치의 제어.계측)

  • Son, Jun-Hyug;Seo, Bo-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2206-2208
    • /
    • 2002
  • In this paper, using the communication port between PC(Personal Computer) and DC/STEP MOTOR DEVICE that movement and measurement of motor. Communication port used serial port and movement order transmits by communication port. Consequence of motor device movement displays to tile DC/STEP MOTOR DEVICE APPLICATION. This connection is using the serial port instead of parallel port faster than response time And this application is easier than existing application.

  • PDF

New Serial and Parallel Sin+Cos PSS1A PSS Design and Analysis

  • Lee Sang-Seung;Li Shan-Ying;Jang Gwang-Soo;Park Jong-Keun;Moon Seung-Il;Yoon Yong-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.378-384
    • /
    • 2005
  • This paper proposes a new series and parallel Sin+Cos PSS (power system stabilizer) for the purpose of improving the existing PSS1A's performance. The purpose of the PSS is to enhance the damping of power system oscillations through injection of auxiliary signals for an excitation control terminal. The proposed series and parallel Sin+Cos PSS is connected adding the Sin+Cos terms additionally with the serial and parallel connection in a conventional PSS1A. The proposed controller is aimed at considering the damping of oscillation when it changes parameter fluctuations or operational load variations in a power system. The electric power system used is the KEPCO system and the voltage of the power transmission line is 154kV and 345kV. The PSCAD/EMTDC package is used to authorize the effect of the proposed controller. Simulations were shown by and compared with the waveforms for frequency, voltage and electric power.

Quench properties of a resistive superconducting fault current limiter by current redistribution (전류재분배에 의한 저항형 초전도 한류기의 퀜치 특성)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Cha, Sang-Do;Hyun, Ok-Bae;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.336-338
    • /
    • 2002
  • We improved quench properties of a superconducting fault current limiter (SFCL) based on YBCO thin films by their serial and parallel combinations. The SFCL consisted of 6 switching elements fabricated of 4 inch-diameter YBCO thin films. Simple serial connection resulted in imbalanced power dissipation between switching elements even at the quench current difference of 0.6A. On the other hand, $2{\times}2\;and\;3{\times}2$ stack combinations produced simultaneous quenches. The $3{\times}2$ stack combination showed better simultaneous quench behavior than the $2{\times}2$ stacks. This is suggested to be because the currents between switching elements in parallel connection of the $3{\times}2$ stacks were more effectively redistributed than the $2{\times}2$ stacks.

  • PDF

Current limiting characteristics of 1-2kV/70A superconducting fault current limiter based on YBCO thin films (1-2kV/70A급 박막형 초전도 한류기의 전류제한 특성)

  • 최효상;현옥배;김혜림;차상도;최용선;임성우;황시돌
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.368-370
    • /
    • 2002
  • We present current limiting properties of 1.2kV/70A superconducting fault current limiter based on YBCO thin films. This is consisted of 6 wafers (3 parallel $\times$ 2 serial connection) with 4 inch-diameter YBCO thin film. The quench current Iq of the switching elements vary between 33.9 and 35.6 A. Within the difference of 0.5 A in the sum of quench current Iq in two stacks, the serial connection of the stacks showed the simultaneous quench behavior in applied power of 1.2 kV/70A.

  • PDF

Development of a resistive superconducting fault current limiter (저항형 초전도 한류기의 개발)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hyun, Ok-Bae;Hwang, Jong-Sun;Jeong, Dong-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.141-144
    • /
    • 2002
  • We present current limiting properties of 1.2kV/70A superconducting fault current limiter based on YBCO thin films. This is consisted of 6 wafers (3 parallel ${\times}$ 2 serial connection) with 4 inch-diameter YBCO thin film. The quench current Iq of the switching elements vary between 33.9 and 35.6 A. Within the difference of 0.5 A in the sum of quench current Iq in two stacks, the serial connection of the stacks showed the simultaneous quench behavior in applied power of 1.2 kV /70 A.

  • PDF

Series and Parallel Sin+Cos PSS (직렬 및 병렬 Sin+Cos 전력계통안정화장치)

  • Lee, Sang-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.87-89
    • /
    • 2005
  • This paper proposes new series and parallel Sin+Cos PSS(power system stabilizer) for the purpose to improve the existing PSS1A's performance. The purpose of PSS is used to enhance damping of power system oscillations through injection of auxiliary signal for an excitation control terminal. The Proposed series and Parallel Sin+Cos PSS is connected adding the Sin+Cos terms additionally with serial and with parallel connection in a conventional PSS1A. The proposed controller is aim to considering of a damping of oscillation when it changes parameter fluctuations or operational load variations in a power system. The object of electric power system is KEPCO system and the voltage of power transmission line is a 154kV and a 345kV. The PSCAD/EMTDC package is used to authorize the effect of the proposed controller. Simulations were shown by and compared with the waveforms for frequency, voltage and electric power.

  • PDF

Characteristics of 15 kVA Superconducting Fault Current Limiters Using Thin Films (15 kVA급 박막형 초전도 전류제한기의 한류특성)

  • 최효상;현옥배;김혜림;황시돌
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1058-1062
    • /
    • 2000
  • We investigated resistive superconducting fault current limites (SFCLs) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 A$\_$peak/, was produced and successfully tested at a 220 V$\_$rms/circuit. From the resistance increase, we estimated that the film temperature increased to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V$\_$rms/.

  • PDF

Characteristics of 15 kVA superconducting fault current limiter (15 kVA급 저항형 초전도 한류기의 전류제한특성)

  • Choi, Hyo-Sang;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon;Lim, Hae-Ryong;Kim, In-Seon;Hyun, Ok-Bae
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.272-275
    • /
    • 2000
  • We investigated a resistive superconducting fault current limiter (SFCL) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 Ap, was produced and successfully tested at a 220 V circuit. From the resistance increase, we estimated that the film temperature increases to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V.

  • PDF