• Title/Summary/Keyword: Separation rate

Search Result 1,380, Processing Time 0.024 seconds

Absorptive Separation of Sulfur Dioxide using Flat Membrane Contactor (평판형 분리막 접촉기를 이용한 이산화황 흡수 분리)

  • Lee Yong-Taek;Lee Young-Jin;Song In-Ho;Jeon Hyun-Soo;Ahn Hyo-Seong;Lee Hyung-Keun
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.196-203
    • /
    • 2006
  • A flue gas emission known to cause an acid rain, containing sulfur dioxide, is tightly controlled by a regulation. The membrane contactor could be one of the alternatives which might be useful technologies for better performance of desulfurization. The fundamental sulfur dioxide separation data were obtained by a flat membrane contactor so that they could be utilized for the full scale membrane contactor. The separation of sulfur dioxide was measured in terms of the concentration of NaOH absorbent, the concentration of sulfur dioxide, the feed flow rate and different membrane materials. As the concentration of absorbent increased, the removal efficiency increased. By increasing the concentration of sulfur dioxide, the removal efficiency decreased. As the feed flow rate increased, it was observed that the removal efficiency decreased. Finally, the effect of the membrane material on separation was found to be negligible.

Comparison of Analysis Performance of Additive Noise Signals by Independent Component Analysis (독립성분분석법에 의한 잡음첨가신호의 분석성능비교)

  • Cho Yong-Hyun;Park Yong-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.294-299
    • /
    • 2005
  • This paper presents the separation performance of the linearly mixed image signals with additive noises by using an independent component analyses(ICAs) of the fixed-point(FP) algorithm based on Newton and secant method, respectively. The Newton's FP-ICA uses the slope of objective function, and the secant's FP-ICA also uses the tangent line of objective function. The 2 kinds of ICA have been applied to the 2 dimensional 2-image with $512\times512$ pixels. Then Gaussian noise and Laplacian noise are added to the mixed images, respectively. The experimental results show that the Newton's FP-ICA has better the separation speed than secant FP-ICA and the secant's FP-ICA has also the better separation rate than Newton's FP-ICA. Especially, the Newton and secant method gives relatively larger improvement degree in separation speed and rate as the noise increases.

Separation of Human Breast Cancer and Epithelial Cells by Adhesion Difference in a Microfluidic Channel

  • Kwon, Keon-Woo;Choi, Sung-Sik;Kim, Byung-Kyu;Lee, Se-Na;Lee, Sang-Ho;Park, Min-Cheol;Kim, Pil-Nam;Park, Suk-Ho;Kim, Young-Ho;Park, Jun-Gyul;Suh, Kahp-Y.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.3
    • /
    • pp.140-150
    • /
    • 2007
  • A simple, label-free microfluidic cell purification method is presented for separation of cancer cells by exploiting difference in cell adhesion. To maximize the adhesion difference, three types of polymeric nanostructures (50nm pillars, 50nm perpendicular and 50nm parallel lines with respect to the direction of flow) were fabricated using UV-assisted capillary moulding and included inside a polydimethylsiloxane (PDMS) microfluidic channel bonded onto glass substrate. The adhesion force of human breast epithelial cells (MCF10A) and human breast carcinoma (MCF7) was measured independently by injecting each cell line into the microfluidic device followed by culture for a period of time (e.g., one, two, and three hours). Then, the cells bound to the floor of a microfluidic channel were detached by increasing the flow rate of medium in a stepwise fashion. It was found that the adhesion force of MCF10A was always higher than that of MCF cells regardless of culture time and surface nanotopography at all flow rates, resulting in a label-free detection and separation of cancer cells. For the cell types used in our study, the optimum separation was found for 2 hours culture on 50nm parallel line pattern followed by flow-induced detachment at a flow rate of $300{\mu}l/min$.

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • Analytical Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.

Effect of Protein Concentration on Foam Separation in a Seawater Aquarium (해수활어수조의 포말분리시 단백질 농도의 영향)

  • SUH Kuen-Hack;SHIN Jeong-Sik;LEE Chang-Kuen;LEE Seok-Hee;CHEON Jae-Kee;JO Jae-Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.1
    • /
    • pp.18-23
    • /
    • 2004
  • Effect of initial protein concentration on the protein removal rate was assessed for seawater aquarium using a foam separator. Protein removal rate was increased and removal efficiency was decreased with the increase of initial protein concentration. Enrichment ratio was decreased and foam generation rate was increased with the increase of initial protein concentration. Total suspended solids (TSS) removal rate was increased with the increase of initial protein concentration, and TSS removal efficiency was decreased with the increase of initial protein concentration. Turbidity removal rate and removal efficiency were increased with the increase of initial protein concentration.

A Study on the Separation of Electrolyte from Amino Acid Solution through Electrodialysis (전기투석법을 이용한 아미노산으로부터 전해질 분리정제에 관한 연구)

  • 김석곤;한정우;김한성;전경용;조영일
    • Membrane Journal
    • /
    • v.4 no.3
    • /
    • pp.163-170
    • /
    • 1994
  • The separation of inorganic salt from amino acid solution using was performed electrodialysis. In order to review the availability of electrodialysis using isoelectric point of amino acid as a bio-separation technique, electrodialysis stacks were designed using ion exchange membrane. Separation of NaCl from amino acid solution was performed in the condition similar to amino acid fermentation process. To obtain otimum conditions of separation, leakage of amino acid depending of pH and limiting current density were measured. On the basis of optimum condition, removal of NaCl and leakage of amino acid were investigated quantitatively in batch and continuous process, and current efficiencies were also obtained. As a result of batch experiment for 11 hours each amino acid solution, removal efficiencies of NaCl were in the ranges of 96.1~96.2%. Amino acid leakage rate of glycine, methionine, alanine were 2.5, 1.7, 2.0% respectively. Current efficiencies were in the ranges of 44.5~44.6%. As a result of continuous experiment in various flow rate of each amino acid solution, it took 120 ~ 150 min to reach to steady state. Removal efficiency of NaCl was increased as the flow rate was decreased, but current efficiency was decreased. At the steady states, there were no leakage of amino acid.

  • PDF

Dynamic Analysis and Design of Star Screen in Recycling Construction Plant (치차형 스크린의 선별 성능 향상을 위한 동적 해석과 설계 형상 변경)

  • Kim, Kwang-Hoon;Park, Jung-Hong;Moon, Byung-Young;Park, Yong-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.219-224
    • /
    • 2010
  • Recycling issue for the construction wastes is gradually important to future society. Recently, a star screen has been developed to use for this purpose, however some modifications were needed to enhance the separation accuracy. The objective of study is to evaluate and predict separation ability by verifying the effect for the modified shapes of the screen part. Two analysis models of the screen part were established using commercial software ADAMS to simulate the dynamic interaction of waste particles. Results showed that spacer and gear shapes directly affected separation ability. The modified spacer shapes were much higher screening rate with comparison to default shape. Screening ability for the half number of gear type was greater than other types. Therefore, modification of the design of screen part will be required to achieve better separation ability.

A Study on the Solid-Liquid Separation of Cooling Water in Ships (선박용 냉각수의 고.액분리에 관한 연구)

  • Choi, M.S.;Kim, J.H.;Jo, D.H.;Han, W.H.;Kim, B.G.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.25-30
    • /
    • 2003
  • Hydrocyclone has been widely used for the solid-Liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range panicle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested solid methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the seperating performance of the Hydrocyclone were investigated. The results from the study are summarized as follows: 1) In proportion to the increase of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in ships, and eventually prevent unexpected accidents in engine systems.

  • PDF

Separation and Purification of Fructo-oligosaccharides by an Ion-Exchange Resin Column (이온교환수지탑을 이용한 Fructo-oligosaccharides의 분리 및 정제)

  • 윤종원;송승구
    • KSBB Journal
    • /
    • v.9 no.1
    • /
    • pp.35-39
    • /
    • 1994
  • Separation of pure fructo-oligosaccharides from the mixed solution of glucose, sucrose and fructo-oligosaccharides was studied using a cationic ion-exchange resin column. Optimum separation conditions, i.e., temperature, feeding rate and the ratio of column vs. diameter were evaluated, which were found to be $85^{\circ}C$, $0.25h^{-1}$ and 30, respectively. At the optimized separation conditions, high-purity fructo-oligosaccharides up to 96% were obtained and the total recovery yield was about 66% after four cycles. After the chromatographic separation, purification to remove the salts and color in pure fructo-oligosaccharides solution was successfully conducted using the mixed-bed of cationic and anionic ionexchange resin columns.

  • PDF

Numerical Study on the Suppression of Shock Induced Separation on a Strongly Heated Wall (강하게 가열된 벽면 위에서 충격파에 의한 경계층 박리의 제거에 관한 수치 연구)

  • LEE Doug-Bong;SHIN Joon-Cheol
    • Journal of computational fluids engineering
    • /
    • v.2 no.2
    • /
    • pp.59-72
    • /
    • 1997
  • A numerical model is constructed to simulate the interactions of oblique shock wave / turbulent boundary layer on a strongly heated wall. The heated wall temperature is two times higher than the adiabatic wall temperature and the shock wave is strong enough to induce boundary layer separation. The numerical diffusion in the finite volume method is reduced by the use of a higher order convection scheme(UMIST scheme) which is a TVD version of QUICK scheme. The turbulence model is Chen-Kim two time scale model. The comparison of the wall pressure distribution with the experimental data ensures the validity of this numerical model. The effect of strong wall heating enlarges the separation region upstream and downstream. In order to eliminate the separation, wall suction is applied at the shock foot position. The bleeding slot width is about same as the upstream boundary layer thickness and suction mass flow is 10% of the flow rate in the upstream boundary layer. The final configuration of the shock reflection pattern and the wall pressure distribution approach to the non-viscous value when wall suction is applied.

  • PDF