• 제목/요약/키워드: Separation performance Standard

검색결과 114건 처리시간 0.019초

기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성( II ) (Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using High Performance Polymer Membranes( II ))

  • 이재달;홍영기;노덕길;배기서
    • 한국염색가공학회지
    • /
    • 제17권4호
    • /
    • pp.21-26
    • /
    • 2005
  • A combination separation system is composed of three parts, simple microfiltration unit for the pretreatment of real waste IPA, pervaporation unit with plate and frame type module(the effective membrane area 9,040$cm^2$), and simple ultrafiltration unit as a refiner. Utrafiltration module with hollow fiber membrane(MWCO 10,000) used to purify waste aqueous IPA solution. In addition, the flux of $CMPA-K^+$ composite membrane for waste aqueous IPA solution was very steady-state with long experiment time(30 days). And the standard deviation($\sigma$) was 0.152 and then the coefficient of variation($CV\%$)was 10.82 The IPA concentration on the membrane performance using pervaporation module system could be increased from $89.85wt(\%)$ to more than $99.90wt\%$ in about 8hr at operation temperature of $70^{\circ}C$ using the pervaporation module system. Therefore, a combination separation process system of simple filtration and pervaporation was very effective for the purpose of the IPA purification and reuse front industrial electronic components cleaning process.

Bayesian forecasting approach for structure response prediction and load effect separation of a revolving auditorium

  • Ma, Zhi;Yun, Chung-Bang;Shen, Yan-Bin;Yu, Feng;Wan, Hua-Ping;Luo, Yao-Zhi
    • Smart Structures and Systems
    • /
    • 제24권4호
    • /
    • pp.507-524
    • /
    • 2019
  • A Bayesian dynamic linear model (BDLM) is presented for a data-driven analysis for response prediction and load effect separation of a revolving auditorium structure, where the main loads are self-weight and dead loads, temperature load, and audience load. Analyses are carried out based on the long-term monitoring data for static strains on several key members of the structure. Three improvements are introduced to the ordinary regression BDLM, which are a classificatory regression term to address the temporary audience load effect, improved inference for the variance of observation noise to be updated continuously, and component discount factors for effective load effect separation. The effects of those improvements are evaluated regarding the root mean square errors, standard deviations, and 95% confidence intervals of the predictions. Bayes factors are used for evaluating the probability distributions of the predictions, which are essential to structural condition assessments, such as outlier identification and reliability analysis. The performance of the present BDLM has been successfully verified based on the simulated data and the real data obtained from the structural health monitoring system installed on the revolving structure.

Determination of Terbutaline Enantiomers in Human Plasma by Coupled Achiral-Chiral High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Kim, Hyun-Ju;Hong, Seon-Pyo;Shin, Sang-Deok
    • Archives of Pharmacal Research
    • /
    • 제23권5호
    • /
    • pp.441-445
    • /
    • 2000
  • Achiral-chiral column switching HPLC assay was developed to allow the separation and quantification of the enantiomers of terbutaline in human plasma by means of fluorescence detection. Plasma samples were prepared by solid-phase extraction with sep-pak silica, followed by HPLC assay. The enantiomers of terbutaline and the internal standard were separated from the biological matrix on a silica column, and the two enantiomers were resolved and quantified on a Sumichiral OA-4900 column. The two columns were connected by a switching valve equipped with silica trap column, The trap column was used to concentrate the terbutaline in the eluent from the achiral column before back flushing onto the chiral phase. For each enantiomers, the assay was linear between 2.5-125 ng/$m\ell$ (r=0.9999) and detection limit was 1.0 ng/$m\ell$ .

  • PDF

뇌졸중 환자를 대상으로 실시한 한글판 기능적 보행평가의 타당도 (Validation of the Korean Functional Gait Assessment in Patients With Stroke)

  • 박소연
    • 한국전문물리치료학회지
    • /
    • 제23권2호
    • /
    • pp.35-43
    • /
    • 2016
  • Background: The Functional Gait Assessment (FGA) was developed to measure of gait-related activities. The FGA was translated in Korean but only a few psychometric characteristics had been studied. Objects: The purpose of this study was to evaluate the validity and reliability of the Korean version of FGA scale using Rasch analysis. Methods: The study included 120 patients with stroke (age range=30~83 years; mean${\pm}$standard deviation=$58.3{\pm}11.1$). The FGA and Berg Balance Scale were performed, and were analysed for dimensionality of the scale, item difficulty, scale reliability and separation, and item-person map using Rasch analysis. Results: The 4 rating scale categories of FGA were satisfied with optimal rating scale criteria. The most items of the FGA showed sound item psychometric properties except 2 items ('gait with the horizontal head turns', and 'gait with narrow base of support'), and the 2 misfit items were excluded for all further analyses. The 8 items were arranged in order of difficulty. The most difficult item was 'gait with eyes closed', the middle difficult item was 'gait level surface', and the easiest item was 'gait with vertical head turns.' A person separation reliability was .93 and the person separation index was 3.57. Conclusion: This study suggests that the 8-item Korean FGA are valid measure of assess the gait-related balance performance, and to set the goal of rehabilitation plan in patient with stroke.

HPLC SEPARATION AND QUANTITATIVE DETERMINATION OF GINSENOSIDES FROM PANAX GINSENG, PANAX QUINQUEFOLIUM AND FROM GINSENG DRUG PREPARATIONS

  • Soldati F
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 1980년도 학술대회지
    • /
    • pp.59-69
    • /
    • 1980
  • A new HPLC-method for separation and quantitative determination of ginsenosides in Panax ginseng, Panax quinquefolium and in pharmaceutical drug preparations is elaborated. A reversed-phase-system with ${\mu}Bondapak\;C_{18}$ column (3.9 mm $I.D.{\times}30\;cm$) using acetonitrile-water (30:70) 2 ml/min and acetonitrile-water (18:82) 4 ml/min is suitable for the base-line separation of $Rb_1,\;Rb_2,\;Rc,\;Rd,\;Rf,\;Rg_2,\;respectively\;Re,\;Rg_1$ in 30 minutes. The ginsenosides are directly detected at 203 nm (without derivatization) with the LC-55 or LC-75 spectrophotometer (Perkin-Elmer) at $100\%$ transmission. Detection limit is 300 ng at a signal-to-noise ratio of 10:1. The ginsenosides-peak identification is carried out with HPTLC (high performance thin layer chromatography), with MIR-IR (multiple internal reflection-IR-spectros-copy) and with FD-MS (field desorption mass spectrometry). The calibration curve of each ginsenoside has a correlation coefficient very near to 1. Relative standard deviation for quantitative determinations depends upon the amount of ginsenosides and is approximately 1\%$ for ginsenoside contents of 1\%$. This method is adaptable for routine analysis in quality control laboratories.

  • PDF

Blind Audio Source Separation Based On High Exploration Particle Swarm Optimization

  • KHALFA, Ali;AMARDJIA, Nourredine;KENANE, Elhadi;CHIKOUCHE, Djamel;ATTIA, Abdelouahab
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권5호
    • /
    • pp.2574-2587
    • /
    • 2019
  • Blind Source Separation (BSS) is a technique used to separate supposed independent sources of signals from a given set of observations. In this paper, the High Exploration Particle Swarm Optimization (HEPSO) algorithm, which is an enhancement of the Particle Swarm Optimization (PSO) algorithm, has been used to separate a set of source signals. Compared to PSO algorithm, HEPSO algorithm depends on two additional operators. The first operator is based on the multi-crossover mechanism of the genetic algorithm while the second one relies on the bee colony mechanism. Both operators have been employed to update the velocity and the position of the particles respectively. Thus, they are used to find the optimal separating matrix. The proposed method enhances the overall efficiency of the standard PSO in terms of good exploration and performance. Based on many tests realized on speech and music signals supplied by the BSS demo, experimental results confirm the robustness and the accuracy of the introduced BSS technique.

헬리컬 노즐의 피치각에 따른 볼텍스 튜브의 성능특성에 관한 연구 (A Numerical Study on the Effect of Pitch Angle of Helical Nozzle on the Vortex Tube Performance Characteristics)

  • 오영택;김귀순
    • 한국유체기계학회 논문집
    • /
    • 제19권1호
    • /
    • pp.11-17
    • /
    • 2016
  • In this paper, a numerical analysis was performed to investigate the effect of the pitch angle of a helical nozzle on the performance characteristics of a vortex tube. Three-dimensional numerical simulation has been performed with standard $k-{\varepsilon}$ turbulence model by using FLUENT 13.0. The effect of the pitch angle of helical nozzle was described in term of ${\beta}$. A CFD analysis was performed on ${\beta}=0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$. In order to realize the influence of ${\beta}$ on performances of the vortex tube. Computation results were expressed by the ${\beta}-{\Delta}T_{h,c}$ graph and radial profiles of axial velocity and swirl velocity. The results showed that ${\beta}$ which improves energy separation capacity of vortex tube was $5^{\circ}$ at ${\alpha}=0.33$, 0.5 and $10^{\circ}$ at ${\alpha}=0.33$. Besides, It was confirmed that the results were closely related to axial velocity and swirl velocity.

N-oleoyl-D-erythro-sphingosine-based Analysis of Ceramide by High Performance Liquid Chromatography and Its Application to Determination in Diverse Biological Samples

  • Lee, Youn-Sun;Choi, Heon-Kyo;Yoo, Jae-Myung;Choi, Kyong-Mi;Lee, Yong-Moon;Oh, Sei-Kwan;Kim, Tack-Joong;Yun, Yeo-Pyo;Hong, Jin-Tae;Okino, Nozomu;Ito, Makoto;Yoo, Hwan-Soo
    • Molecular & Cellular Toxicology
    • /
    • 제3권4호
    • /
    • pp.273-281
    • /
    • 2007
  • Ceramide is involved in cell death as a lipid mediator of stress responses. In this study, we developed an improved method of ceramide quantification based on added synthetic ceramide and thin layer chromatography (TLC) separation, and applied to biological samples. Lipids were extracted from samples spiked with N-oleoyl-D-erythro-sphingosine ($C_{17}$ ceramide) as an internal standard. Ceramide was resolved by TLC, complexed with fatty-acidfree bovine serum albumin (BSA), and deacylated by ceramidase (CDase). The released sphingosine was derivatized with o-phthalaldehyde (OPA) and measured by high performance liquid chromatography (HPLC). The limit of detection for ceramide was about 1-2 pmol and the lower limit of quantification was 5 pmol. Ceramide recovery was approximately 86-93%. Ceramide concentrations were determined in biological samples including cultured cells, mouse tissues, and mouse and human plasma. TLC separation of ceramide provides HPLC chromatogram with a clean background without any interfering peaks and the enhanced solubility of ceramide by BSAceramide complex leads to the increased deacylation of ceramide. The use of an internal standard for the determination of ceramide concentration in these samples provides an accurate and reproducible analytical method, and this method can be applicable to diverse biological samples.

인삼 사포닌의 High Performance Liquid Chromatography에 의한 분리 (High Performance Liquid Chromatographic Determination of Ginseng Saponins)

  • 홍순근;박은규;이춘영;김명운
    • 약학회지
    • /
    • 제23권3_4호
    • /
    • pp.181-186
    • /
    • 1979
  • A high performance liquid chromatograpic procedure is described for determining ginseng saponins such as ginsenoside-Rb1, -Rb2, -Rc, -Rd, -Re, -Rf, -Rg1, and-Rg2. Ginseng saponins extracted with 90% methanol and water-saturated butanol were compared with pure standard ginsenosides. The resolution of the saponins was satisfactory and detection limit for each saponin was about 5.mu.g. Separation of the saponins was accomplished using a .mu. Bondapak carbohydrate analysis column, mobile phase of acetonitrile-water-butanol (80:20:15) and differential refractive index (RI) detector. The reproducibility and the recovery were also studied. This method was applied for determining the saponin contents of several parts of leaf, fresh ginseng, white ginseng, and red ginseng.

  • PDF

New N-way Hybrid Power Combiner to Improve the Graceful Degradation Performance

  • Eom, Soon-Young;Kim, Jeong-Ho;Yim, Choon-Sik
    • ETRI Journal
    • /
    • 제16권1호
    • /
    • pp.59-72
    • /
    • 1994
  • In this paper, a new N-way hybrid power combiner for improving the graceful degradation performance has been proposed. The proposed combiner has been configured with two dummy transmission lines per each section, where each dummy transmission line has a different characteristic impedance, of the standard combiner. Under this proposed configuration, a detailed theoretical analysis has been performed to show the general function of a power combiner. When any M amplifiers among N identical amplifiers are suffering the failure mode in a power combining circuit or system, the graceful degradation performance has been improved due to the separation of a transmission line and an internal resistor in every failed section from the proposed combiner by simultaneously operating two shorting devices. Simulation results for all the items which can be measured from all the items which can be measured from the proposed combiner with an eight-way configuration have been presented.

  • PDF