• Title/Summary/Keyword: Separation of Sn

Search Result 49, Processing Time 0.023 seconds

Separation of Valuable Metal from Waste Photovoltaic Ribbon through Extraction and Precipitation

  • Chen, Wei-Sheng;Chen, Yen-Jung;Yueh, Kai-Chieh
    • Resources Recycling
    • /
    • v.29 no.2
    • /
    • pp.69-77
    • /
    • 2020
  • With rapid increasing production and installation, recycling of photovoltaic modules has become the main issue. According to the research, the accumulation of waste modules will reach to 8600 tons in 2030. Moreover, Crystalline-silicon (c-Si) Photovoltaic modules account for more than 90% of the waste. C-Si PV modules contain 1.3% of weight of photovoltaic ribbon inside which contains the most of lead, tin and copper in the PV modules, which would cause environmental and humility problem. This study provided a valuable metal separation process for PV ribbons. Ribbons content 82.1% of Cu, 8.9% of Sn, 5.2% of Pb, and 3.1% of Ag. All of them were leached by 3M of hydrochloric acid in the optimal condition. Ag was halogenated to AgCl and precipitated. Cu ion was extracted and separated from Pb and Sn by Lix984N then stripped by 3M H2SO4. The effect of the optimal parameters of extraction was also studied in this essay. The maximum extraction efficiency of Cu ion was 99.64%. The separation condition of Pb and Sn were obtained by adjusting the pH value to 4 thought ammonia to precipitate and separate Pb and Sn. The recovery of Pb and Sn can reach 99%.

Separation of Rh(III) from the Mixed Chloride Solutions Containing Pt(IV) and Pd(II) by Extraction with Alamine336

  • Sun, Panpan;Lee, Myung-Ho;Lee, Man-Seung
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1945-1950
    • /
    • 2010
  • Solvent extraction experiments of Pt(IV), Pd(II) and Rh(III) by Alamine336 were performed from the mixed chloride solutions. In the HCl concentration range from 1 to 5 M, most of Pt and Pd were extracted from the mixed solutions. However, the extraction percentage of Rh was much smaller than that of Pt and Pd. Lower concentration of Alamine336 in strong HCl solution led to higher separation factor of Rh from Pt and Pd. Adding $SnCl_2$ to the mixed solutions increased the extraction percentage of Rh, while the extraction percentage of Pt and Pd was little affected. Our results showed that selective separation of Rh or coextraction of the three platinum group metals from the mixed solution would be possible by adjusting the extraction conditions.

A study on the interfacial reactions between electroless Ni-P UBM and 95.5Sn-4.0Ag-0.5Cu solder bump (무전해 Ni-P UBM과 95.5Sn-4.0Ag-0.5Cu 솔더와의 계면반응 및 신뢰성에 대한 연구)

  • ;;Sabine Nieland;Adreas Ostmann;Herbert Reich
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.05a
    • /
    • pp.85-91
    • /
    • 2002
  • Even though electroless Hi and Sn-Ag-Cu solder are widely used materials in electronic packaging applications, interfacial reactions of the ternary Ni-Cu~Sn system have not been known well because of their complexity. Because the growth of intermetallics at the interface affects reliability of solder joint, the intermetallics in Ni-Cu-Sn system should be identified, and their growth should be investigated. Therefore, in present study, interfacial reactions between electroless Ni UB7f and 95.5Sn-4.0Ag-0.5Cu alloy were investigated focusing on morphology of the IMCs, thermodynamics, and growth kinetics. The IMCs that appear during a reflow and an aging are different each other. In early stage of a reflow, ternary IMC whose composition is Ni$_{22}$Cu$_{29}$Sn$_{49}$ forms firstly. Due to the lack of Cu diffusion, Ni$_{34}$Cu$_{6}$Sn$_{60}$ phase begins growing in a further reflow. Finally, the Ni$_{22}$Cu$_{29}$Sn$_{49}$ IMC grows abnormally and spalls into the molten solder. The transition of the IMCs from Ni$_{22}$Cu$_{29}$Sn$_{49}$ to Ni$_{34}$Cu$_{6}$Sn$_{60}$ was observed at a specific temperature. From the measurement of activation energy of each IMC, growth kinetics was discussed. In contrast to the reflow, three kinds of IMCs (Ni$_{22}$Cu$_{29}$Sn$_{49}$, Ni$_{20}$Cu$_{28}$Au$_{5}$, and Ni$_{34}$Cu$_{6}$Sn$_{60}$) were observed in order during an aging. All of the IMCs were well attached on UBM. Au in the quaternary IMC, which originates from immersion Au plating, prevents abnormal growth and separation of the IMC. Growth of each IMC is very dependent to the aging temperature because of its high activation energy. Besides the IMCs at the interface, plate-like Ag3Sn IMC grows as solder bump size inside solder bump. The abnormally grown Ni$_{22}$Cu$_{29}$Sn$_{49}$ and Ag$_3$Sn IMCs can be origins of brittle failure.failure.

  • PDF

Separation of Nickel and Tin from copper alloy dross (구리 합금 부산물에서의 주석과 니켈의 분리)

  • Lee, Jung-Il;Hong, Chang Woo;Ryu, Jeong Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.5
    • /
    • pp.224-228
    • /
    • 2014
  • Recently, the demands for separation/recovery of valuable metals such as nickel or tin from copper based alloys has been attracting much attention from the viewpoints of environmental protection and resource utilization. In this report, experimental results on concentration increasement of nickel and tin compared to the previous report are investigated. Ni is successfully separated by a organic solvent and reduced to the metal powder whose concentration is over 98 %. Sn is separated by a selective solution method and its concentration is increased to 97.5 % by three consecutive solution and reduction process. Crystal structure, surface morphology and microstructure of the separated samples are studied.

Separation of Metals from Intergrated Circuit Chip Scrap by Mechanical Beneficiation (기계적 처리에 의한 반도체 IC칩 스크랩으로부터 유가금속의 분리에 관한 연구)

  • 이재천;이강인;이철경;양동효
    • Resources Recycling
    • /
    • v.3 no.1
    • /
    • pp.38-43
    • /
    • 1994
  • The separation of valuable metals from IC chip scrap generated by domestic electronic company was carried out using the mechanical beneficiation such as shredding, crushing, screening and magnetic separation. The distribution of metals in various sizes of crushed IC chip scrap was investigated and metals present in crushed products was separated with the magnetic separator. The particle size distribution of crushed IC chip scrap was 7.5% for +3mm, 17.0% for 3~1mm and 75.5% for -1mm. The weight loss of crushed IC chip scrap was 18% when roasted at $700^{\circ}C$. The content of metals was 96% for +3~1mm, 13% for 1~0.595mm, 3.7% for 0.95~0.5. Au of 99% was present in -1mm crushed IC chip scrap. Ni, Fe, Cu, Sn and Pb were separated from crushed IC chip scrap by the magnetic separator under 700 and 2, 500 Gauss.

  • PDF

Investigation of Liposomes Labelled with Tc-99m Added EDTA, DTPA and NTA for Tumor Seeker ($^{99m}Tc-Liposomes$과 킬레이트제 표지반응의 효과)

  • Ryu, Yong-Wun;Kim, Jang-Hwi;Kang, Tae-Woong;Yu, Ju-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.1
    • /
    • pp.137-143
    • /
    • 1985
  • Using chelating agents such as Nitrilotriaceticacid(NTA), ticacid(DTPA) and Ethylenediaminenitrilotetraceticacid(EDTA), with TC-99m were determined in vitro and in vivo. Methods.of separation and determination of TC-99m-liposomes added chelating agents were practiced by thin layer chromatogram scan and gel filtration. Biodistributions of Tc-99m-liposomes in normal and sarcoma 180 cells bearing mice were observed. The results were as follows: 1) Maximum amount of $Sn^{+2}$ to reduction from pertechnetium$(10\sim20{\mu}ci)$ by adding 0, 1, 10 and $100{\mu}g$ of $SnCl_2$ in 0.2 ml of oxygen free water was $10{\mu}g$. 2) The large amounts of $SnCl_2$ were not changed but the small amounts of $SnCl_2$ were much changed by labeling with TC-99m to add chelating agents. EDTA in small amounts of $SnCl_2$ were reduced more strongly than DTPA or NTA. Using a hydrophilic chelate, DTPA, the uptake of liposomes could not accumulated in liver and spleen by a lipophilic chelate NTA were significant in vivo. 3) Uptake by tumor was achived 1.14% of injected dose per gram tissue and tumor to organ ratios were measured in low with TC-99m-NTA-liposomes(+).

  • PDF

Effect of Melting and Pouring Conditions on Structures of Leaded Tin Bronze Castings (연청동주물(鉛靑銅鑄物)의 조직(組織)에 미치는 용해(熔解) 및 주입조건(鑄入條件)의 영향(影響)에 관한 연구(硏究))

  • Lee, W.W.;Choi, C.O.
    • Journal of Korea Foundry Society
    • /
    • v.7 no.1
    • /
    • pp.45-52
    • /
    • 1987
  • The effects of melting and casting conditions on cast structures of Cu-Sn-Pb alloys were studied. Specimens were prepared at different pouring temperatures of $1100^{\circ}C$ to $1260^{\circ}C$ with use of various kind of molds, green sand mold, $CO_2$ sand mold, shell mold, furan sand mold and metallic mold. (1) The transition of equiaxed to columnar structure greatly influenced by adding elements and mold binders. (2) The change of equiaxed structure according to pouring temperatures were expressed by separation theory. Lower pouring temperature and rapid cooling rate increase hardness and it's further increase was shown in the region of columnar structure. (3) Proper controls of pouring temperature, cooling rate and mold binder were important factors to improve wear properties of Cu-Sn-Pb alloys castings.

  • PDF

Design of User Privacy Model for Strong Reliability in SNS Environment (SNS 환경에서 신뢰성이 강한 사용자 프라이버시 모델 설계)

  • Jeong, Yoon-Su;Kim, Yong-Tae
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.237-242
    • /
    • 2013
  • SNS is emerging as an academic and social interest, as Facebook and Twitter are developed explosively. But, SNS has a problem of exposing user's privacy because it is originated by exchanging user's personal information and opinion. This paper proposes SNS user privacy protecting model using data separation and false data information instead of blocking which is using to protect user's personal privacy. The proposed model do not let the third party extract precise information after collecting user's context information by adding false information to separated context information. Also, it gets user's agreement beforehand if SNS service provider uses user's information not to be used illegally by the third party.

Activation Effect on Palladium Electroless Plating of Porous Stainless Steel Support (팔라듐 무전해 도금을 위한 활성화 처리에 대한 연구)

  • 허장은;우상국;서동수;한성욱;한인섭;서두원
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.165-170
    • /
    • 1999
  • Palladium membranes have high selectivity of separation and removal of hydrogen to chemical process at high temperature. For the development of hydrogen permeable membrane, palladium was deposited on porous stainless steel support by electroless plating method. In this work, the activation effect on the surface of stainless steel support has been investigated for the effective palladium plating. The morphology and microstructure were characterized by SEM and the composition was analyzed by EDX. It is found that the composition of deposited nuclei on the stainless steel support was changed in accordance with activation cycles. It is also observed that Sn-enriched nuclei has been changed to Pd-enriched nuclei over the fifteenth activation. The uniform deposition of the dense palladium layer on porous stainless steel support has been performing with Sn-enriched nuclei and comparing with Pd-enriched nuclei.

  • PDF

Ion Exchange Separation of Minor Elements from Iron for the Analysis of S/G Sludge

  • Park, Kyoung-Kyun;Choi, Kwang-Soon;Kim, Jong-Goo
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.309-310
    • /
    • 2005
  • Some minor elements(Al, B, Ba, Ca, Cd, Co, Cr, Cu, Gd, Mg, Mn, Mo, Nd, Ni, P, Pb, Si, Sn, Sr, Ti, V, Yb, Zn and Zr) in iron compounds such as the S/G sludge of a power plant were separated from iron by anionic and cationic exchange methods. If a ICP-AES or AAS determination follows this method, minor elements of more than 2 or 20 ppm of Fe can be determined with an error less than 20% except Sn and Mo. Alkaline elements were excluded from this study since they can be easily recovered from an anionic exchange. Application to real sludge samples is ongoing.

  • PDF