• Title/Summary/Keyword: Separation isotopes

Search Result 64, Processing Time 0.02 seconds

The Evaluation of 166Ho Product by Double Neutron Capture from HANARO Research Reactor (하나로를 이용한 중성자 이중 포획반응에 의한 166Ho 생성량 평가)

  • Kim, Jong-Bum;Choi, Kang-Hyuk
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.111-117
    • /
    • 2015
  • In this paper, production of $^{166}Ho$ by double neutron capture from HANARO research reactor was evaluated. This production approach provides $^{166}Ho$ with high specific activity. $^{164}Dy$ is transmuted into $^{165g+m}Dy$ by (n,${\gamma}$) reaction, then $^{165g+m}Dy$ is transmuted into $^{166}Dy$ by (n,${\gamma}$) reaction. At the end of neutron irradiation, population of $^{166}Dy$ atoms reaches highest point. And $^{164}Dy$ exists as a mixture with $^{165m}Dy$, $^{165}Dy$, $^{166}Ho$ and $^{165}Ho$ at this point. To obtain $^{166}Ho$ with high specific activity, Ho isotopes from irradiated target is separated out. Then $^{166}Ho$ decayed from $^{166}Dy$ is eluted at radioactive equilibrium state. At each step, the number of relevant nuclide is calculated by the state equation. The neutron irradiation time for maximum $^{166}Dy$ is calculated for 283 hour. When 100 mg target of $Dy_2O_3$ (96.8% enriched $^{164}Dy$) is used, possible activity of $^{166}Ho$ is 3.54 Ci($1.31{\times}10^{11}Bq$). For separation efficiency of Dy/Ho is 99.99%, $^{166}Ho/Ho$ is 0.62.

Automated Cold Volume Calibration of Temperature Variation in Cryogenic Hydrogen Isotope Sorption Isotherm (극저온(20K) 수소동위원소 흡착 등온선의 온도 변화에 대한 자동 저온 부피 교정)

  • Park, Jawoo;Oh, Hyunchul
    • Korean Journal of Materials Research
    • /
    • v.29 no.5
    • /
    • pp.336-341
    • /
    • 2019
  • The gas adsorption isotherm requires accurate measurement for the analysis of porous materials and is used as an index of surface area, pore distribution, and adsorption amount of gas. Basically, adsorption isotherms of porous materials are measured conventionally at 77K and 87K using liquid nitrogen and liquid argon. The cold volume calibration in this conventional method is done simply by splitting a sample cell into two zones (cold and warm volumes) by controlling the level sensor in a Dewar filled with liquid nitrogen or argon. As a result, BET measurement for textural properties is mainly limited to liquefied gases (i.e. $N_2$ or Ar) at atmospheric pressure. In order to independently investigate other gases (e.g. hydrogen isotopes) at cryogenic temperature, a novel temperature control system in the sample cell is required, and consequently cold volume calibration at various temperatures becomes more important. In this study, a cryocooler system is installed in a commercially available BET device to control the sample cell temperature, and the automated cold volume calibration method of temperature variation is introduced. This developed calibration method presents a reliable and reproducible method of cryogenic measurement for hydrogen isotope separation in porous materials, and also provides large flexibility for evaluating various other gases at various temperature.

Development of an exclusive column method for 82Sr/82Rb generator using a 100 MeV proton linear accelerator of KOMAC

  • Kye-Ryung Kim;Yeong Su Ha;Sang-Pil Yoon;Yeon-ji Lee;Yong-Sub Cho;Hyeongi Kim;Sang-Jin Han;Jung Young Kim;Kyo Chul Lee;Jin Su Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.119-125
    • /
    • 2021
  • 82Sr for 82Rb generator was produced through the irradiation of the proton beam on the nat.RbCI target at the target irradiation facility installed at the end of the Rl-dedicated beamline of the 100 MeV proton linear accelerator of KOMAC (Korea Multi-purpose Accelerator Complex). The average current of the proton beam was 1.2 µA for irradiation time of 150 min. For the separation and purification of the 82Sr from nat.RbCI irradiated, Chelex-100 resin was used. The activities of 82Sr in the irradiated nat.RbCI target solution and after purification were 45.29 µCi and 43.4 µCi, respectively. The separation and purification yield was 95.8%. As an adsorbent to be filled in the generator for 82Sr adsorption hydrous tin oxide was selected. The adsorption yield of 82Sr into the generator adsorbent was > 99 %, and the total amount of 82Sr adsorbed to the generator was 21.6 µCi as of the day of the 82Rb elution experiment. When the elution amount was 22 mL, the maximum82Rb elution yield was 93.3%, and the elution yield increased as the flow rate increased. After the eluted 82Rb was filled in the correction phantom of the small PET for animals, a PET image was taken. The image scan time was set to 5 min, and the phantom PET image was successfully obtained. As results of impurity analysis on eluted 82Rb using ICP-MS, nat.Rb stable isotopes that compete in vivo of 82Rb were identified as undetected levels and were determined to be No-Carrier-Added (NCA).

Molybdenum Isotope Analysis of Standard Reference Materials (표준물질을 이용한 몰리브덴 동위원소 분석)

  • Jo, Yunsoo;Kil, Youngwoo;Ryu, Jongsik;Seol, Junghwan;Nguyen, The Cong;Jung, Woochul;Park, Sanghee
    • Economic and Environmental Geology
    • /
    • v.49 no.2
    • /
    • pp.89-95
    • /
    • 2016
  • Mo isotope, one of highly redox-sensitive isotopes, has been shown to be useful tracers of geochemical processes. Many studies for Mo isotope have documented with the help of recently developed analysis tools, but it has not yet been documented in the Korea. In this study, we introduce two-stage column separation method of Mo using column tube (BioRad PolyPrep(R) column, 10 ml) and anion exchange resin (BioRad Resin AG(R) 1-X8, 200-400 mesh). Mo isotope ratios in the solid SRMs (BHVO-2, SDO-1, PACS-2) and liquid SRM (IAPSO) were measured on MC-ICP-MS (Multi-collector Inductively Coupled Plasma Mass Spectrometer) and then compared with reference Mo isotope ratios. Mo isotope ratios in our study overlap with reference Mo isotope ratios within analytical error.