• Title/Summary/Keyword: Separation condition

Search Result 866, Processing Time 0.031 seconds

Distribution of the Reynolds Stress Tensor Inside Tip Leakage Vortex of a Linear Compressor Cascade (I) - Effect of Inlet Flow Angle - (선형 압축기 익렬에서 발생하는 익단 누설 와류내의 레이놀즈 응력 분포 (I) -입구 유동각 변화의 영향-)

  • Lee, Gong-Hee;Park, Jong-Il;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.902-909
    • /
    • 2004
  • A steady-state Reynolds averaged Navier-Stokes simulation was conducted to investigate the distribution of the Reynolds stress tensor inside tip leakage vortex of a linear compressor cascade. Two different inlet flow angles ${\beta}=29.3^{\circ}$(design condition) and $36.5^{\circ}$(off-design condition) at a constant tip clearance size of $1\%$ blade span were considered. Classical methods of solid mechanics, applied to view the Reynolds stress tensor in the principal direction system, clearly showed that the high anisotropic feature of turbulent flow field was dominant at the outer part of tip leakage vortex near the suction side of the blade and endwall flow separation region, whereas a nearly isotropic turbulence was found at the center of tip leakage vortex. There was no significant difference in the anisotropy of the Reynolds normal stresses inside tip leakage vortex between the design and off-design condition.

Statistical evaluation of the cleft lip nose deformity image (구순열 환자 코변형(cleft lip nose deformity) 영상의 통계적 평가)

  • Nam, Ki-Chang;Kim, Jin-Tae;Hong, Hyun-Ki;Rah, Dong-Kyun;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.45-47
    • /
    • 2005
  • Cleft lip is a congenital deformity condition with separation of the two sides of the lip and results in nose deformity. Evaluation of surgical corrections and outcome assessments in nose deformity resulting from the cleft lip depend mainly on doctor's objective judgment. Development of an objective assessment tool in evaluation of the condition and surgical outcome of cleft lip nose deformity patients will help in advancement and evaluation of surgical techniques of cleft lip. Hence, our study aimed on quantitative assessment of a cleft lip nose deformity condition by comparing following parameters gathered from a photographic image of a cleft lip patient: (1) angle difference between two nostril axis, (2) center of the nostril and distance between two centers, (3) overlapped area of two nostrils and (4) the overlapped area ratio of two nostrils. Assessment results of the nose deformity were determined by statistical analysis of evaluation results from three greatly experienced plastic surgeons. In addition, regression model was developed using correlation relationship and factor analysis of parameters from results of the image analysis.

  • PDF

Treatment Efficiency of Complex Wastewater by Fenton's Oxidation Condition (펜톤산화에 따른 복합폐수의 처리효율연구)

  • Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.446-450
    • /
    • 2006
  • In order to treat the wastewater containing organic compound, pre-treatment system connected with MSP(molecular separation process) was investigated. With the aim of selecting an optimum process of Fenton's oxidation, removal efficiency of each process in the optimum reaction condition was recommended. The $Fe/H_{2}O_{2}$(ferric sulfate to hydrogen peroxide)reagent is referred to as the Fenton's regent, which produces hydroxyl radicals by the interaction of Fe with $H_{2}O_{2}$. The powerful oxidizing ability and extreme kinetic reactively of the hydroxyl radical was well established. Increasing dosage of $Fe/H_{2}O_{2}$ increased removal efficiency as molar ratio of $Fe/H_{2}O_{2}$ between 0.2 and 2.5. Optimum dosage of molar ratio was 1. The removal efficiency for reaction condition was increased as pH decreased when the molar ratio of $Fe/H_{2}O_{2}$ was 1.7. Fenton's oxidation was most efficient in the reaction time 35 min for complex wastewater. Also, coagulation aid experiments using kaolin resulted in 3% of kaolin dosage.

Statistical Evaluation of the Cleft Lip Nose Deformity Image (구순열 환자 코변형(Cleft Lip Nose Deformity) 영상의 통계적 평가)

  • Kim, Jin-Tae;Nam, Ki-Chang;Hong, Hyun-Ki;Rah, Dong-Kyun;Kim, Deok-Won
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.8
    • /
    • pp.517-520
    • /
    • 2005
  • Cleft lip is a congenital deformity condition with separation of the two sides of the lip and results in nose deformity Evaluation of surgical corrections and outcome assessments in nose deformity resulting from the cleft lip depend mainly on doctor's objective judgment. Development of an objective assessment tool in evaluation of the condition and surgical outcome of cleft lip nose deformity patients will help in advancement and evaluation of surgical techniques of cleft lip. Hence, our study aimed at quantitative assessment of a cleft lip nose deformity condition by comparing following parameters gathered from a photographic image of a cleft lip patient: (1) angle difference between two nostril axis, (2) center of the nostril and distance between two centers, (3) overlapped area of two nostrils and (4) the overlapped area ratio of two nostrils. Assessment results of the nose deformity were determined by statistical analysis of evaluation results from three experienced plastic surgeons. In addition, regression model was developed using correlation relationship and factor analysis of parameters from results of the image analysis

Optimum Condition of HPLC by HCI Program (HCI 프로그램을 이용한 HPLC의 최적화 조건)

  • Jin, Chun Hua;Lee, Ju Weon;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.555-562
    • /
    • 2006
  • Recently, liquid chromatography (LC) has been used more frequently to separate drugs and natural substances. Especially, to selection of the solutes from the products, the operation condition of analytical chromatography should be necessarily determined. So accurate computer modeling and simulation of chromatographic performances has become a necessary part of the development and design of processes. High-Purity Separation Lab. Inha University developed the resulting HCI software for the purpose of the optimization of chromatographic performances. The HCI program was utilized to find the optimum operating condition more accurately and rapidly, reducing the number of many possible experiments. The elution profiles were calculated by the plate theory based on the three retention mechanism of capacity factor.

Chiral Separation of Derivatized Racemic Alcohols on Substitued Cyclodextrin Stationary Phases by Capillary Gas Chromatography (모세관 기체 크로마토그래피에 의한 치환된 Cyclodextrin 정지상을 이용한 알코올 유도체의 키랄분리)

  • Lee, Sun-Haing;Seo, Yeong-Ju;Lee, Kwang-Pill
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.2
    • /
    • pp.94-102
    • /
    • 1995
  • S-Hydroxypropyl(PH) ${\beta}$-cyclodextrin(hydrophilic), dialkyl(DA)-cyclodextrin(hydrophobic), trifluoroacetyl(TA) ${\gamma}$-cyclodextrin(intermediate) stationary phases were used for gas chromatographic separation of racemic alcohols and their derivatives. All the alcohols used for this experiment were derivatived by using trifluoro acetic anhydride, acetic anhydride, or trichloro acetic anhydride. It is apparent that the enantioselectivity of the enantiomeric pairs was very dependent on the type of acylation reagent. The best experimental condition of optical resolution of the alcohols and their derivatives was different on the polarity of the solute molecules. The chiral separation was also studied depending on temperature, polarity of the column, and hydrogen bonding ability and steric effect between the alchols and CD stationary phase. The chiral recognition mechanism is dependent not upon the kinds of the chiral stationay phases but upon the derivatization of the racemic alchols.

  • PDF

Carbon Dioxide Separation by Hollow Fiber Membrane of Polyethersulfone : Comparison of Experimental Results with Numerical Analysis Data (Polyethersulfone 중공사 분리막에 의한 이산화탄소 분리 : 실험과 수치해석 비교)

  • Lee, Yong-Taek;Song, In-Ho;Ahn, Hyo-Seong;Jeon, Hyung-Soo;Joung, Houn-Kyu;Kim, Jeong-Hoon;Lee, Soo-Bok
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.134-139
    • /
    • 2007
  • Experimental and numerical analysis were performed for separation of carbon dioxide from carbon dioxide and nitrogen gas mixture using a polyethersulfone hollow fiber membrane. The experimental results were compared with those obtained at the same operating condition by the numerical analysis. It was observed that there was a big difference between the experimental results and those by a numerical analysis where the permeance of carbon dioxide and its ideal selectivity over nitrogen were obtained from the pure gas permeation. Therefore, the permeance of carbon dioxide and its selectivity were obtained from the separation experimental results using the numerical analysis as a function of the mole fraction of carbon dioxide, the feed pressure and the permeate pressure in the gas mixture. The results of the numerical analysis using the selectivity obtained from the gas mixture were in good agreement with those of the experimental.

Wet Purification for the Selective Separation of Montmorillonite from Bentonite (벤토나이트로부터 몬모릴로나이트의 선택적 분리를 위한 습식 고순도화)

  • 김완태;채영배;정수복;임정한
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.293-304
    • /
    • 2002
  • Wet purification process for the selective separation of montmorillonite from Gampo 13 and 35 bentonite ores was studied using physical processes such as ultrasonic scrubbing, decantation and centrifugation. Ultrasonic Scrubbing of Gampo 13 and 35 bentonite ores was revealed excellent result at 7 wt.% of slurry density and was almost finished within 30 minutes in the sample of Gampo 13 and 10 minutes in the sample of Gampo 35, respectively After decantation, approximately 52 wt.% from the bentonite of Gampo 13 and 64wt.% from the bentonite of Gampo 35 were recovered as purified products and the CEC was reached up to 119.4 meq/100 g and 124.5 meq/100 g, respectively. Particle separation by centrifugation showed that most of the impurity minerals such as quartz and feldspar were removed within the condition of 1,000 rpm.

A Study on the Extraction of Collagen and Separation of Chrome Ion from Leather Waste (피혁 폐기물로부터 collagen 추출과 크롬이온 분리에 관한 연구)

  • Lim, Bong-Ju;Lim, Nam-Uoong;Lim, Han-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.1
    • /
    • pp.43-52
    • /
    • 1998
  • The objective of this study is to investigate the optimum conditions of extracting collagen without chrome ion from the leather waste. The effect of temperature, pH, and the concentration of alkaline solution on the collagen extraction has been studied. The result indicated that the incipient denatured temperature of collagen measured by viscosity was $25^{\circ}C$ and the complete denatured temperature was $31.5^{\circ}C$. The optimum solubilization condition for temperature was between $15^{\circ}C$ and $20^{\circ}C$, pH was 1.5, the concentration of alkaline solution was 3% of sodium hydroxide. The almost complete chrome ion separation was possible around the pH of 1.5. The separation efficiency of chrome ion from tannery waste was more than 99.5%. Extraction efficiency of crude protein from leather waste was about 89.5%. The hydroxyproline and collagen content in the extracted crude protein were 8.53% and 63.62%, respectively.

  • PDF

Structural Analysis of TPU Membrane Plate in Multi-purpose Module for Solid-liquid Separation (TPU 재질을 적용한 다목적 고액분리 모듈의 여과판 구조해석)

  • Jung, Hee Suk;Oh, Doo Young;Ko, Dong Shin;Song, Hyoung Woon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.1
    • /
    • pp.5-13
    • /
    • 2017
  • Polypropylene is the main existing material in the domestic market being used for the filter plate because of its moldability, low cost, and commercial availability. Polypropylene filter plate once distorted due to the high-pressure during operation may cause the problem in the continuous operation of the solid-liquid separation module. Thermoplastic Poly Urethane (TPU) can be a high-performance alternative material for the filter plate in the solid-liquid separation module of the dehydration process. Hence, to predict and evaluate the TPU for structural stability in the filter plate through analytical techniques designed and experimental verification is essential. As a result, TPU filter plate had maximum strain of 27.85 MPa at 20 bar pressure condition. This result is less than TPU stress-strain limit, which ensures the structural stability of the TPU material.