• Title/Summary/Keyword: Separation Coefficient

Search Result 432, Processing Time 0.032 seconds

A Study on Mean Coefficient of Separation during Compression Molding of Fiber-Reinforced Thermoplastics (섬유강화 열가소성 고분자 복합판의 압축성형에 있어서 평균분리계수에 관한 연구)

  • Kang, K;Jo, S.H.;Lee, D.G.;Kim, E.G
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1146-1153
    • /
    • 1996
  • The properties of FRP(fiber-reinforced plastics) depend not only on the characteristics of the matrix but also on the structure of fiber mat and the fiber type of reinforcement. Therefore it is very important to study the characteristics of reinforcement and matrix. In this paper, a method is proposed which can be used to measure the mean coeffcient of separation for the press molding of FRP, and the mean equivalent coefficient of separation is obtained from the separation coefficient. And the relationship between the mean equivalent coefficient of separation and the structure of fiber mat is discussed. The effects of corrlelation coefficient between separation and orientation on the mean equivalent coefficient are also presented.

Rejection Characteristics of Various Heavy Metals by Low-pressure Nanofiltration (저압나노여과에 의한 각종 중금속의 제거 특성)

  • Oh, Jeong-Ik;Kim, Han-Seung;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.493-499
    • /
    • 2004
  • Rejection characteristics of heavy metals by nanofiltration membranes were investigated. Nanofiltration membranes rejected heavy metals much better than chloride, sulfate and TOC, of which concentration in synthetic wastewater was higher than that of heavy metals. To consider rejection characteristics of various metals by nanofiltration membranes, separation coefficient, which is the ratio of the metal permeation rate to the chloride ion or TOC permeation rate, was introduced. In spite of different materials and different nominal salt rejection of nanofiltration membrane used, the separation coefficients of metals were nearly the same. In particular, the separation coefficient of arsenic against chloride ion and TOC was larger than any other separation coefficient of heavy metals. These phenomena were observed in the relationship between the molar conductivity and the separation coefficient for heavy metals.

Critical Wedging Coefficient in Frictional Elastic System Considering Separation State (분리 상태를 고려한 탄성마찰시스템의 임계 쐐기 계수)

  • Kim, Sangkyu;Jang, Yong Hoon
    • Tribology and Lubricants
    • /
    • v.36 no.6
    • /
    • pp.324-331
    • /
    • 2020
  • Wedging in a frictional elastic system is defined if the state of stick exists after the external loading on the system is removed. This paper presents a method to determine the critical coefficient of wedging for an elastic frictional system by considering the separation state. Wedging is always possible if the coefficient of friction exceeds a critical value known as the critical wedging coefficient. This method requires two concepts: a necessary and sufficient condition for wedging, which can be interpreted as positive spanning sets of constraint vectors existing in the wedged system, and the minimal positive basis that enables a minimum wedging coefficient. The algorithm based on the positive spanning concept is repeatedly executed after eliminating nodes from the contact stiffness matrix, for which the separation states are impending. The simulation results show that once a node enters the separation state, it never returns to the contact state again and the critical wedging coefficient reduces during repeated algorithm execution. The benefit of this method is that the computation time permits handling models with large numbers of contact nodes. The algorithm can also numerically find the critical wedging coefficient, thereby contributing to fastening and assembly performance improvements in mechanical systems.

Evaluation of the Effective Charge Density on Low Pressure Nanofiltration with the Separation Characteristics of Monovalent and Divalent Solutes in the Production of Drinking Water

  • Oh, Jeong-Ik;Taro, Urase
    • Environmental Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • The electric charge on a membrane was investigated by analyzing the experimental rejection of various monovalent and divalent ionic solutes. The characteristics of the separation of ionic solutes using various nanofiltration membranes were obtained from an experimental nanofiltration set-up, with a surface area of $40cm^2$ under the operational pressures between 0.25-0.3 MPa. The state of the membrane electric charge was observed using separation coefficients, i.e., the permeation ratio of monovalent to divalent ions. To confirm the state of the membrane charge observed via the separation coefficient, a calculation using the extended Nernst-Planck equation, coupled with the Donnan equilibrium, assuming different electric charge states of the membrane, was compared with the experimental rejection of ionic solutes. The examination of the characteristics of separation using three types of nanofiltration membranes showed that one of the membranes carried a negative/positive double charge density inside, while other two membranes carried either a positive or negative charge density.

Separation and Characterization of Dust and Ground Water Particulates Using Gravitational SPLITT Fractionation.

  • Lee, Seung Ho;Park, Hui Yeong;Lee, Sang Geun;Yong, Seong Gwon;Eum, Cheol Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.6
    • /
    • pp.616-622
    • /
    • 2001
  • Split-flow thin (SPLITT) cell Fractionation(SF) is a technique that allows separation of particulates and macromolecules into two fractions. A gravitational SF(GSF) system is constructed and tested for its applicability for separation of dust and ground water particulates. When tested with polystyrene latex particles, experimental data were in good agreements with theory. The 9.8 and 21.4㎛ polystyrene particles were successuflly separated in a continuous mode, where the mixture is continuously fed into the GSF channel allowing separation in a large sacle. The GSF system is successfully applied to continuous separation of dust and ground water particels based on the sedimentation coefficient, which is closely related to the particle size. The separations were confirmed by microscopy and energy-dispersive X-ray (EDX) analysos.

Changes in Facilitated Transport Behavior of Silver Polymer Electrolytes by UV Irradiation

  • Jongok Won;Yosang Yoon;Kang, Yong-Soo
    • Macromolecular Research
    • /
    • v.10 no.2
    • /
    • pp.80-84
    • /
    • 2002
  • Silver species other than the silver ion were formed by UV irradiation on polymer electrolyte membranes containing silver salts and their effect on complexation behavior between the silver and olefin was investigated through the separation performance of olefin/paraffin mixtures. The ideal propylene/propane separation factor reached 350 and the separation coefficient was ca.15 due to the high loading amount of silver ions into poly(2-ethyl-2-oxazoline) (POZ) without UV irradiation. On UV irradiation either in air or under nitrogen, the silver-POZ membranes became yellow-brown initially due to the formation of colloidal silver particles, and finally black and metal-like luster. Even when Ag$^{+}$ was converted, to some extent, to Ag$^{\circ}$ by UV irradiation in air at the early stage, the separation coefficient of olefin/paraffin mixtures was maintained. This suggests that silver species other than the silver ion is active for olefin carrier for facilitated transport. Meanwhile the steady decrease of the separation coefficient was observed in the silver/POZ membranes irradiated under $N_2$. It is suggested that the reduction of silver ions in POZ goes through a different photoreduction mechanism with UV irradiation depending on the environment.t.

Blind Noise Separation Method of Convolutive Mixed Signals (컨볼루션 혼합신호의 암묵 잡음분리방법)

  • Lee, Haeng-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.409-416
    • /
    • 2022
  • This paper relates to the blind noise separation method of time-delayed convolutive mixed signals. Since the mixed model of acoustic signals in a closed space is multi-channel, a convolutive blind signal separation method is applied and time-delayed data samples of the two microphone input signals is used. For signal separation, the mixing coefficient is calculated using an inverse model rather than directly calculating the separation coefficient, and the coefficient update is performed by repeated calculations based on secondary statistical properties to estimate the speech signal. Many simulations were performed to verify the performance of the proposed blind signal separation. As a result of the simulation, noise separation using this method operates safely regardless of convolutive mixing, and PESQ is improved by 0.3 points compared to the general adaptive FIR filter structure.

Analysis of Broken Rice Separation Efficiency of a Laboratory Indented Cylinder Separator

  • Kim, Myoung Ho;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • Purpose: Using a laboratory indented cylinder separator, broken rice separation experiments were conducted and the characteristics of the separation process were studied to provide information for developing a prototype indented cylinder broken rice separator. Methods: Rice (Ilmi variety) milled in a local RPC was used for the experiment. Rice kernels were classified into four groups according to their length l; whole kernels (I > 3.75 mm), semi-whole kernels (2.5 < I < 3.75 mm), broken kernels (1.75 < I < 2.5 mm), and foreign matters (I < 1.75 mm). A laboratory grain cleaner, Labofix '90 (Schmidt AG, Germany) was used for the experiments. Experiments were designed as a $4{\times}4$ factorial arrangement in randomized blocks with three replications. Cylinder rotational speeds (17, 34, 51, 68 rpm) and trough angles (15, 37.5, 60, $82.5^{\circ}$) were the two factors and feed rates (25, 50 kg/h), indent shapes (Us, $S_1$ type), and indent sizes (2.5, 3.75 mm) were treated as the blocks. Two 125 g samples and one 125 g sample were taken at the cylinder outlet and from the trough, respectively. The whole, semi-whole, and broken kernel weight ratio of the samples and feed was determined by a rice sizing device. From these weight ratios, purities, degrees of extraction and coefficient of separation efficiency were calculated. Results: Trough angle, cylinder speed, and their interaction on the coefficient of separation efficiency were statistically significant. Cylinder speed of 17, 34, and 51 rpm made the most effective separation when the trough angle was $15^{\circ}$ or $37.5^{\circ}$, $60^{\circ}$, and $82.5^{\circ}$, respectively. Maximum values of coefficient of separation efficiency were in the range of 60 to 70% except when the indent size was 2.5 mm and were recorded for the combinations of low cylinder speed (17 rpm) with medium trough angle ($37.5^{\circ}$ or $60^{\circ}$). Indent shape did not appear to make any noticeable difference in separation efficiency. Conclusions: Due to the interaction effect, the trough angle needs to be increased appropriately when an increase in cylinder speed is made if a rapid drop of effectiveness of separation should be avoided. In commercial applications, $S_1$ type indents are preferred because of their better manufacturability and easier maintenance. For successful separation of broken kernels, the indent size should be set slightly bigger than the actual sizes of broken kernels: an indent size of 3.0 mm for separating broken kernels shorter than 2.5 mm.

Analysis on Wave Absorbing Performance of a Pile Breakwater (파일 방파제의 소파성능 해석)

  • Cho, Il-Hyoung;Koh, Hyeok-Jun
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Based on the eigenfunction expansion method, the wave-absorbing performance of a square or circular pile breakwater was investigated. Flow separation resulting from sudden contraction and expansion is generated and is the main cause of significant energy loss. Therefore, evaluation of an exact energy loss coefficient is critical to enhancing the reliability of the mathematical model. To obtain the energy loss coefficient, 2-dimensional turbulent flow is analyzed using the FLUENT commercial code, and the energy loss coefficient can be obtained from the pressure difference between upstream and downstream. It was found that energy loss coefficient of circular pile is 20% that of a square pile. To validate the fitting equation for the energy loss coefficient, comparison between the analytical results and the experimental results (Kakuno and Liu, 1993) was made for square and circular piles with good agreement. The array of square piles also provides better wave-absorbing efficiency than the circular piles, and the optimal porosity value is near P=0.1.

Nanoporous graphene oxide membrane and its application in molecular sieving

  • Fatemi, S. Mahmood;Arabieh, Masoud;Sepehrian, Hamid
    • Carbon letters
    • /
    • v.16 no.3
    • /
    • pp.183-191
    • /
    • 2015
  • Gas transport through graphene-derived membranes has gained much interest recently due to its promising potential in filtration and separation applications. In this work, we explore Kr-85 gas radionuclide sequestration from natural air in nanoporous graphene oxide membranes in which different sizes and geometries of pores were modeled on the graphene oxide sheet. This was done using atomistic simulations considering mean-squared displacement, diffusion coefficient, number of crossed species of gases through nanoporous graphene oxide, and flow through interlayer galleries. The results showed that the gas features have the densest adsorbed zone in nanoporous graphene oxide, compared with a graphene membrane, and that graphene oxide was more favorable than graphene for Kr separation. The aim of this paper is to show that for the well-defined pore size called P-7, it is possible to separate Kr-85 from a gas mixture containing Kr-85, O2 and N2. The results would benefit the oil industry among others.