• Title/Summary/Keyword: Seoul Station

Search Result 1,226, Processing Time 0.03 seconds

Comparison of Methods for Estimating Extreme Significant Wave Height Using Satellite Altimeter and Ieodo Ocean Research Station Data (인공위성 고도계와 이어도 해양과학기지 관측 자료를 활용한 유의파고 극값 추정 기법 비교)

  • Woo, Hye-Jin;Park, Kyung-Ae;Byun, Do-Seung;Jeong, Kwang-Yeong;Lee, Eun-Il
    • Journal of the Korean earth science society
    • /
    • v.42 no.5
    • /
    • pp.524-535
    • /
    • 2021
  • Rapid climate change and oceanic warming have increased the variability of oceanic wave heights over the past several decades. In addition, the extreme wave heights, such as the upper 1% (or 5%) wave heights, have increased more than the heights of the normal waves. This is true for waves both in global oceans as well as in local seas. Satellite altimeters have consistently observed significant wave heights (SWHs) since 1991, and sufficient SWH data have been accumulated to investigate 100-year return period SWH values based on statistical approaches. Satellite altimeter data were used to estimate the extreme SWHs at the Ieodo Ocean Research Station (IORS) for the period from 2005 to 2016. Two representative extreme value analysis (EVA) methods, the Initial Distribution Method (IDM) and Peak over Threshold (PoT) analysis, were applied for SWH measurements from satellite altimeter data and compared with the in situ measurements observed at the IORS. The 100-year return period SWH values estimated by IDM and PoT analysis using IORS measurements were 8.17 and 14.11 m, respectively, and those using satellite altimeter data were 9.21 and 16.49 m, respectively. When compared with the maximum value, the IDM method tended to underestimate the extreme SWH. This result suggests that the extreme SWHs could be reasonably estimated by the PoT method better than by the IDM method. The superiority of the PoT method was supported by the results of the in situ measurements at the IORS, which is affected by typhoons with extreme SWH events. It was also confirmed that the stability of the extreme SWH estimated using the PoT method may decline with a decrease in the quantity of the altimeter data used. Furthermore, this study discusses potential limitations in estimating extreme SWHs using satellite altimeter data, and emphasizes the importance of SWH measurements from the IORS as reference data in the East China Sea to verify satellite altimeter data.

Development of pan coefficient model for estimating evaporation: focused on Seoul station (증발량 산정을 위한 증발접시계수 산정모형 개발: 서울지점을 중심으로)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.7
    • /
    • pp.557-567
    • /
    • 2020
  • The six current models for estimating pan coefficient were applied to test the applicability of models in Seoul, South Korea. The models are Cuenca's model, Snyder's model, Pereira et al.'s model, Allen et al.'s model, Orang's model, and Raghuwanshi and Wallender's model. The estimated pan coefficients were compared with measured one. The measured pan coefficient was obtained by using measured pan evaporation and FAO Penman-Monteith reference evapotranspiration. Estimated evaporation by using estimated pan coefficients was compared with measured one. Furthermore, model for estimating pan coefficient in Seoul was developed. When applying 6 current models for 10 m, 15 m and 20 m fetch distances, pan coefficient estimates from Snyder's model were most similar to measured pan coefficients for all fetch distances. On the other hand, pan coefficient estimates from Pereira et al.'s model were most different from measured one. Therefore, model for estimating pan coefficient in Seoul was developed by modifying Snyder's model. When applying developed model, estimated monthly average evaporation was 92.1 mm for 10 m, 15 m and 20 m fetch distances and measured one was 91.9 mm, indicating that evaporation estimate from developed model is closest to measured one, compared with those of current models.

Monitoring of Bisphenol A and Nonylphenol in Waterworks System of Seoul, Korea (상수도 계통에서 비스페놀 A와 노닐페놀의 실태조사)

  • Ham, Young-Kook;Oh, Sea-Jong;Kim, Sung-Whan
    • Analytical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.423-433
    • /
    • 2004
  • This study was examined occurrence of bisphenol A (BPA) and nonylphenol (NP) in waterworks system of Seoul, Korea from September 2002 to December 2003. The levels of BPA and NP in Han-river and its tributaries were as followed: Paldang-dam, ND(not detected)${\sim}0.033{\mu}g/L$ and $ND{\sim}0.823{\mu}g/L$; Kyungahn-creek, $ND{\sim}0.659{\mu}g/L$ and $ND{\sim}3.827{\mu}g/L$; Whangsuk-creek, $ND{\sim}0.528{\mu}g/L$ and $ND{\sim}12.724{\mu}g/L$, respectively. In water of 6 intake-station, the contents of NP and BPA were detected $0.122{\sim}2.724{\mu}g/L$, and $ND{\sim}0.260{\mu}g/L$, respectively. In the finished- and tap-water of three drinking water treatment plants (DWTPs) around Whangsuk-creek, BPA was not detected in all samples, while NP was in ppt levels in whole. Through the process of DWTP, also, the removal ratio of NP was above 80% in all this. Therefore, this result was suggested that levels of BPA and NP in waterworks system depended on non-point contaminants and swage treatment plants in the Han-river shed.

Compensation of Light Scattering Method for Real-Time Monitoring of Particulate Matters in Subway Stations (지하역사 내 미세먼지 실시간 모니터링을 위한 광산란법 보정)

  • Kim, Seo-Jin;Kang, Ho-Seong;Son, Youn-Suk;Yoon, Sang-Lyeor;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, In-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.533-542
    • /
    • 2010
  • The $PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the underground subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. As for the measurement of $PM_{10}$ concentrations, instruments based on $\beta$-ray absorption method and gravimetric methods are being used. But the instruments using gravimetric method give us 20-hour-average data and the $\beta$-ray instruments can measure the $PM_{10}$ concentration every one hour. In order to keep the $PM_{10}$ concentrations under a healthy condition, the air quality of the underground platform and tunnels should be monitored and controlled continuously. The $PM_{10}$ instruments using light scattering method can measure the $PM_{10}$ concentrations every less than one minute. However, the reliability of the instruments using light scattering method is still not proved. The purpose of this work is to study the reliability of the instruments using light scattering method to measure the $PM_{10}$ concentrations continuously in the underground platforms. One instrument using $\beta$-ray absorption method and two different instruments using light scattering method (LSM1, LSM2) were placed at the platform of the Jegi station of Seoul metro line Number 1 for 10 days. The correlation between the $\beta$-ray instrument and the LSM2 ($r^2$=0.732) was higher than that between the $\beta$-ray instrument and the LSM1 ($r^2$=0.393). Thus the LSM2 was chosen for further analysis. Three different regression analysis methods were tested: Linear regression analysis, Nonlinear regression analysis and Orthogonal regression analysis. When the instruments using light scattering method were used, the data measured these instruments have to be converted to actual $PM_{10}$ concentrations using some factors. With these analyses, the factors could be calculated successfully as linear and nonlinear forms with respect to the data. And the orthogonal regression analysis was performed better than the ordinary least squares method by 28.45% reduction of RMSE. These findings propose that the instruments using light scattering method light scattering method can be used to measure and control the $PM_{10}$ concentrations of the underground subway stations.

The Source Identification of Spilled Oil by Pristane/Phytane Ratio

  • Bae, Il-Sang;Kweon Jung;Oh, Hyun-Jung;Shin, Ho-Sang;Lee, Jae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.4
    • /
    • pp.64-67
    • /
    • 2003
  • In order to identify the origin and nature of the spilled oil in the potential source, we analyzed the concentrations of specific fuel constituents in fuel standard and environmental samples. The ratios of pristane/phytane are virtually unaltered because these compounds have the same bolatility in environmental samples. These were useful to identify the source of the fuel oil and to assess the effect of microbial degradation and weathering of the fuel oil. We analyzed the ratios of pristane/phytane in neat white kerosene, boiler kerosene, JP-8 and diesel products from L and S gas station. The ratios of pristane/phytane in L-white kerosene and JP-8 was 3.10 $\pm$0.03 and 1.77 $\pm$ 0.01, respectively. Otherwise, the ratios of pristane/phytane in water phase after distribution of fuel oil and water was 2.97 $\pm$0.02 in case of white kerosene and 1.65 $\pm$ 0.02 in case of JP-8. It is apparent from the results that the ratios of pristane/phytane were as product-specific, especially between kerosene and JP-8, and therefore, can also be used for fuel type identification in free products and groundwater samples which were collected in monitoring wells.

Quality Characteristics of Yogurt Supplemented with Angelica gigas Nakai Leaf Extract (참당귀잎 추출물을 첨가한 요구르트의 품질 특성)

  • Kim, JiYoun;Han, JeongA;Kang, Hyeoncheol;Lee, Jaehak;Kim, Hee-Yeon;Lim, Young-Soon
    • Journal of Dairy Science and Biotechnology
    • /
    • v.37 no.4
    • /
    • pp.237-246
    • /
    • 2019
  • In this study, quality characteristics of yogurt supplemented with Angelica gigas Nakai leaf extract were examined. The pH of the yogurt ranged from 4.40 to 4.45 and the titratable acidity ranged from 0.96% to 0.98%. The viscosity tended to decrease with the addition of the Angelica gigas Nakai leaf extract, but did not affect stability during storage. In the range of 0.1% to 0.3%, lactic acid bacteria were present in the range of 1.9×109 to 3.2×109 CFU/mL. The decursin content in yogurt was quantitatively analyzed, depending on the addition of 0.1% to 0.3% of Angelica gigas Nakai leaf extract and was found to be 0.26 ㎍/g, 15.23 ㎍/g, and 23.57 ㎍/g respectively. Organic acid showed the highest generation of lactic acid. The antioxidant properties of yogurt were shown to increase with the addition of the Angelica gigas Nakai leaf extract. The sensory score of yogurt supplemented with 0.1% of the Angelica gigas Nakai leaf extract was highly valued, at a level similar to that of plain yogurt. Yogurt supplemented with 0.2% of the extract was rated above the normal score of 6.31 to 6.50. As shown by the results, the optimal concentration of Angelica gigas Nakai leaf extract for addition to yogurt was within 0.2%.

Distribution of $^{222}Rn$ Concentration in Seoul Subway Stations (서울지역 지하철역의 라돈농도 분포 특성)

  • Jeon, Jae-Sik;Kim, Dok-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.588-595
    • /
    • 2006
  • Indoor radon($^{222}Rn$) concentrations of subway stations in Seoul area were measured to survey the environmental indoor radon levels and to identify sources of radon. The radon concentration of indoor air by method of long-term measuring with a-track detector were surveyed at 232 subway stations from 1998 to 2004. And the radon concentration in ground-water was measured with a method of alpha particle counting. To trace main source of radon, 8 out of 232 stations were selected and their radon concentrations in tunnel and on platform were analyzed. Total geometric mean and arithmetic mean of radon concentrations in all stations from 1998 to 2004 were $1.40{\pm}1.94pCi/L,\;1.65{\pm}1.07$ respectively. Geometric means of radon concentrations on platform and concourse were $1.54{\pm}1.96pCi/L,\;1.23{\pm}1.88pCi/L$ respectively, with higher concentration at the platform than at the concourse. The geological structure was significantly correlated to the indoor radon concentration in subway stations region. Radon concentrations of adjacent tunnel and ground-water of subway station was significantly correlated to the indoor radon concentration in subway stations. And There was a significant difference in radon concentration, depending on the depth levels in platform of subway stations(p<0.05).

Spatial distribution of particulate matters in comparison with land-use and traffic volume in Seoul, Republic of Korea (서울시 토지이용과 교통량에 따른 미세먼지의 공간분포)

  • Jeong, Jong-Chul;Lee, Peter Sang-Hoon
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.1
    • /
    • pp.123-138
    • /
    • 2018
  • To sustainably monitor air pollution in Seoul, the number of Air Pollution Monitoring Station has been gradually increased by Korea's Ministry of Environment. Although particulate matters(PM), one of the pollutants measured at the stations, have an significant influence on human body, the concentration of PM in Korea came in second among 35 OECD member countries. In this study, using the data of PM concentration from the stations, distribution maps of PM10 and PM2.5 concentrations over Seoul were generated, and spatial factors potentially related to PM distribution were investigated. Based on a circumscribed hexagon about a circle in radius of 500 meters created as a basic unit, Seoul was sectionalized and PM concentration map was generated using the interpolation technique of 'inverse distance weighting'. The distributions of PM concentrations were investigated with commuting time by administrative district and the outcome was related with land-use type and volume of traffic. Results from this analysis indicated distribution pattern of PM10 concentration was different from that of PM2.5 by administrative district and time. The distribution of PM concentration was strongly related to not only the size of business and trafficked areas among the land-use type, but also the existence of urban green. Further analysis of the relationship between the PM concentration and detailed land-use and urban green maps can be helpful to identify spatial factors which have an impact on the PM concentration on the regional scale.

The Component Characteristics and the Distribution Channels for Forest Products Consumed as a Fuel in Kyeongseong City (Seoul) in 1929 (1929년 경성부(京城府)에서 소비(消費)된 임산연료(林産燃料)의 구성별(構成別) 특성(特性)과 유통(流通) 경로(經路))

  • Lee, Ki-Bong;Bae, Jae-Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.3 s.160
    • /
    • pp.135-145
    • /
    • 2005
  • The purpose of this study is to reveal the component characteristics and the channels of distribution for forest products as a fuel that were consumed in Kyeongseong city (Seoul) in 1929, in the middle of the colonial period. The summary of the results are as follows; (1) though the average consumption of forest products consumed as a fuel per household in Kyeongseong city was slightly less than one-third as much forest products as fuel consumed in other counties of Kyeongki province, but due to the high heat capacity, the amount of fuelwood and charcoal consumption was much higher than leaf and grass consumption; (2) the largest supply areas of forest products for fuel were the riverside of Kangwon province and Kyeonggi province in which the waterways were available. They supplied 42.6% of total consumption, and the other supply areas were the northern part of Kyeonggi province, etc. (29.5%) where railroads were handy, and the suburbs of Kyeongseong City (27.9%) by roads; (3) the transportation areas using the Han River were divided into two parts of Ttook island (43.0%) and former Yongsan and Mapo (45.6%), but the volume of transportation by railroad was centralized in Kyeongseong Station, which accounted for 72.2% of total volume of transportation by rail; (4) the most of the forest products consumed for fuel in Kyeongseoung city were sold in temporary fuelwood markets, rather than permanent and regular markets.

Air Quality Monitoring System Using NDIR-CO$_2$ Sensor for Underground Space based on Wireless Sensor Network (비분산적의선 CO$_2$센서를 이용한 무선 센서 네트워크 기반의 지하 공기질 모니터링 시스템)

  • Kwon, Jong-Won;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.28-38
    • /
    • 2009
  • In this study, a remote air quality monitoring system for underground spaces was developed by using NDIR-based CO$_2$ sensor. And the remote monitoring system based on wireless sensor networks was installed practically on the subway station platform. More than 6.5 million citizens commutate everyday by the Seoul subway transportation that is the most typical public transportation. They concern about air quality with increasing interest on public health or many workers in subway stations or underground shopping centers. Recently, the Korean Ministry of Environment has operated the air quality monitoring system in some subway stations for testing phase. However, it showed many defects which are large-scale, high-cost and maintenance of precision sensors imported from abroad. Therefore this research includes the reliability test and a theoretical study about the inexpensive commercialized CO$_2$ sensor for reliable measurement of air quality which changes rapidly by the surrounding environments. And then we develop the wireless sensor nodes and the gateway applied for remote air quality monitoring. In addition, web server program was realized to manage air quality in the subway platform. This result will be valuable for a basic research for air quality management in underground spaces for future study.