• 제목/요약/키워드: Sensor element

검색결과 847건 처리시간 0.032초

Thick-film ammonia gas sensor with high sensitivity and excellent selectivity

  • Lee, Kyuchung;Ryu, Kwang-Ryul;Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • 제2권1호
    • /
    • pp.22-25
    • /
    • 2004
  • A highly sensitive ammonia gas sensor using thick-film technology has been fabricated and examined. The sensing material of the gas sensor is FeOx-$WO_{3}-SnO_{2}$ oxide semiconductor. The sensor exhibits resistance increase upon exposure to low concentration of ammonia gas. The resistance of the sensor is decreased, on the other hand, for exposure to reducing gases such as ethyl alcohol, methane, propane and carbon monoxide. A novel method for detecting ammonia gas quite selectively utilizing a sensor array consisting of an ammonia gas sensor and a compensation element has been proposed and developed. The compensation element is a Pt-doped $WO_{3}-SnO_{2}$gas sensor which shows opposite direction of resistance change in comparison with the ammonia gas sensor upon exposure to ammonia gas. Excellent selectivity has been achieved using the sensor array having two sensing elements.

힘과 온도 측정을 위한 생체모방형 촉각센서 감지부 설계 (Design of sensing .element of bio-mimetic tactile sensor for measurement force and temperature)

  • 김종호;이상현;권휴상;박연규;강대임
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1029-1032
    • /
    • 2002
  • This paper describes a design of a tactile sensor, which can measure three components force and temperature due to thermal conductive. The bio-mimetic tactile sensor, alternative to human's finger, is comprised of four micro force sensors and four thermal sensors, and its size being 10mm$\times$10mm. Each micro force sensor has a square membrane, and its force range is 0.1N - 5N in the three-axis directions. On the other hand, the thermal sensor for temperature measurement has a heater and four temperature sensor elements. The thermal sensor is designed to keep the temperature. $36.5^{\circ}C$, constant, like human skin, and measure the temperature $0^{\circ}C$ to $50^{\circ}C$. The MEMS technology is applied to fabricate the sensing element of the tactile sensor.

  • PDF

PVDF 필름 형상최적화에 의한 복합재료 쉘의 진동제어 시스템 설계 (Vibration Control System Design of Composite Shell by Profile Optimization of PVDF film)

  • 황준석;목지원;김승조
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 추계학술발표대회 논문집
    • /
    • pp.228-231
    • /
    • 2000
  • The active vibration control of laminated composite shell has been performed with the optimized sensor/actuator system. PVDF film is used fur the material of sensor/actuator. Finite element method is utilized to model the whole structure including the piezoelectric sensor/actuator system, The distributed selective modal sensor/actuator system is established to prevent the adverse effect of spillover. In the finite element discretization process, the nine-node shell element with five nodal degrees of freedoms is used. Electrode patterns and lamination angles of sensor/actuator are optimized using genetic algorithm. Sensor is designed to minimize the observation spillover, and actuator is designed to minimize the system energy of the control modes under a given initial condition. Modal sensor/actuator profiles are optimized for the first and the second modes suppression of singly curved cantilevered composite shell structure. Discrete LQG method is used as a control law. The real time vibration control with profile optimized sensor/actuator system has been performed. Experimental result shows successful performance of the integrated structure for the active vibration control.

  • PDF

무선 랜 통신을 이용한 기계 상태감시용 스마트 센서 (Smart Sensor for Machine Condition Monitoring Using Wireless LAN)

  • 태성도;손종덕;양보석;김동현
    • 한국소음진동공학회논문집
    • /
    • 제19권5호
    • /
    • pp.523-529
    • /
    • 2009
  • Smart sensor is known as intelligent sensor, it is different with other conventional sensors in the case of intelligent system embedded on it. Smart sensor has many benefits e.g. low-cost in usage, self-decision and self-diagnosis abilities. This sensor consists of perception element(sensing element), signal processing and technology of communication. In this work, a bridge and structure of smart sensor has been investigated to be capable to condition monitoring routine. This investigation involves low power consumption, software programming, fast data acquisition ability, and authoritativeness warranty. Moreover, this work also develops smart sensor to be capable to perform high sampling rate, high resolution of ADC, high memory capacity, and good communication for data transfer. The result shows that the developed smart sensor is promising to be applied to various industrial fields.

재활로봇용 3축 힘/토크센서 설계 (Design of Three-Axis Force/Torque Sensor for Rehabilitation Robot)

  • 정재현;김갑순
    • 한국정밀공학회지
    • /
    • 제33권4호
    • /
    • pp.309-316
    • /
    • 2016
  • In this study, we described the design of a three-axis force/torque sensor for measuring the force and torque in a lower-limb rehabilitation robot. The three-axis force/torque sensor is composed of Fx force sensor, Fz force sensor and Tz torque sensor. The sensing element for Fx force sensor and Tz torque sensor is used in a two-step parallel plate beam, and that of Fz force sensor is used in a parallel plate beam. The rated loads of Fx force sensor, Tz torque sensor and Fz force sensor are 300 N, 15 N m and 100 N, respectively. The three-axis force/torque sensor was designed using the finite element method, and manufactured using strain-gauges. The three-axis force sensor was further characterized. As a result, the interference error of the three-axis force/torque sensor was < 1.24%, the repeatability error of each sensor was < 0.03%, and the non-linearity was < 0.02%.

유한요소 해석을 이용한 초탄성체 햅틱 피드백 연구 (Hyper-elastic Model Haptic Feedback Using Finite Element Analysis)

  • 박승현;김진현
    • 센서학회지
    • /
    • 제31권4호
    • /
    • pp.260-265
    • /
    • 2022
  • In this study, we establish hyper-elastic haptic feedback in a virtual environment using finite element analysis techniques and develop a Force Torque (FT) sensor utilization method for application in tele-operation environments. In general, regarding haptic feedback data, in a tele-operation environment, the user is provided with feedback according to the measured force data when the model is inserted through an FT sensor. Conversely, in a virtual environment, the press-fitting model can be expressed through the spring-damper system rather than an FT sensor to provide feedback. However, unlike rigid and the elastic bodies, the hyper-elastic body represented by a spring-damper system in a virtual environment is a simple impedance model using stiffness and damping coefficients; it is limited in terms of providing actual feedback. Thus, in this study, haptic feedback was implemented using the data obtained from POD-RBF analysis results during hyper-elastic press-fitting experiments. The haptic feedback mechanism developed in this study was verified by comparing the FT sensor feedback data measured and calculated through hyper-elastic press-fitting experiments with spring-damper feedback data. Subsequently, the POD-RBF analysis feedback was compared and evaluated against the feedback mechanism of each environment through the test subject, and the similarities between the POD-RBF analysis feedback and FT sensor data feedback were verified.

Sensor placement strategy for high quality sensing in machine health monitoring

  • Gao, Robert X.;Wang, Changting;Sheng, Shuangwen
    • Smart Structures and Systems
    • /
    • 제1권2호
    • /
    • pp.121-140
    • /
    • 2005
  • This paper presents a systematic investigation of the effect of sensor location on the data quality and subsequently, on the effectiveness of machine health monitoring. Based on an analysis of the signal propagation process from the defect location to the sensor, numerical simulations using finite element modeling were conducted on a bearing test bed to determine the signal strength at several representative sensor locations. The results showed that placing sensors closely to the machine component being monitored is critical to achieving high signal-to-noise ratio, thus improving the data quality. Using millimeter-sized piezoceramic plates, the obtained results were evaluated experimentally. A comparison with a set of commercial vibration sensors verified the developed structural dynamics-based sensor placement strategy. It further demonstrated that the proposed shock wave-based sensing technique provided an effective alternative to vibration measurement, while requiring less space for sensor installation.

A new method for optimal selection of sensor location on a high-rise building using simplified finite element model

  • Yi, Ting-Hua;Li, Hong-Nan;Gu, Ming
    • Structural Engineering and Mechanics
    • /
    • 제37권6호
    • /
    • pp.671-684
    • /
    • 2011
  • Deciding on an optimal sensor placement (OSP) is a common problem encountered in many engineering applications and is also a critical issue in the construction and implementation of an effective structural health monitoring (SHM) system. The present study focuses with techniques for selecting optimal sensor locations in a sensor network designed to monitor the health condition of Dalian World Trade Building which is the tallest in the northeast of China. Since the number of degree-of-freedom (DOF) of the building structure is too large, multi-modes should be selected to describe the dynamic behavior of a structural system with sufficient accuracy to allow its health state to be determined effectively. However, it's difficult to accurately distinguish the translational and rotational modes for the flexible structures with closely spaced modes by the modal participation mass ratios. In this paper, a new method of the OSP that computing the mode shape matrix in the weak axis of structure by the simplified multi-DOF system was presented based on the equivalent rigidity parameter identification method. The initial sensor assignment was obtained by the QR-factorization of the structural mode shape matrix. Taking the maximum off-diagonal element of the modal assurance criterion (MAC) matrix as a target function, one more sensor was added each time until the maximum off-diagonal element of the MAC reaches the threshold. Considering the economic factors, the final plan of sensor placement was determined. The numerical example demonstrated the feasibility and effectiveness of the proposed scheme.

에어컨 냉매압 측정용 정전용량형 압력센서 소자의 전기적 특성 연구 (A Study on Electrical Characteristics of a Capacitive Pressure Sensor Element to Measure the Pressure of Refrigerant of Air-Conditioner)

  • 최가현;정우영;최정운;김시동;민준원
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.208-213
    • /
    • 2015
  • The purpose of this study is to optimize the design of a capacitive pressure sensor element using the simulation of electrical characteristics. The simulation of the ceramic sensor diaphragm ($Al_2O_3$) was performed by permitting pressure to change the curvature of the diaphragm. The pressure capacitance ($C_P$) was increased from 19.63 pF to 15.26 pF by applying pressure because the distance between the electrodes has been changed from $30{\mu}m$ to $15{\mu}m$. When the thickness of the diaphragm was changed to 0.46~0.52 mm, a larger capacitance change showed in accordance with the reduced thickness, which means an increase of sensitivity. However, considering the viewpoint of the signal linearity, it was selected for the optimum thickness of the diaphragm to 0.50 mm. The designed sensor element based on simulated results was tested to measure the output characteristics. Comparing of simulated and measured results, there was a margin of error of approximately 2%.

복합재료 지능구조물의 제어를 위한 압전소자를 이용한 변형형상예측 (Shape Estimation for the Control of Composite Smart Sstructure Using Piezoceramics)

  • 하성규;조영수
    • 대한기계학회논문집A
    • /
    • 제20권4호
    • /
    • pp.1133-1145
    • /
    • 1996
  • A method is proposed to predict the deformed shape of the structure subjected to the unknown external loads using the signal from the piezoceramic sensors. Such a shape estimation is based on the linear relationship between the deformation of structure and the signal from sensor, which is calculated using finite element method. The deformed shape is, then calculated using the linear matrix and the signals from the piezoceramic sensors attached to the structures. For the purpose, a structural analysis program is developed using a multi-layerd finite element of 8 nodes with 3 displacement and one voltage degrees of freedom at each node. The multiple layers with the different material properties can be layered within the element. The incompatible mode with the element is found to be crucial to catch the bending behavior accurately. The accuracy of the program is, then, verified by being compared with the experimental results performed by Crawley. The proposed shape estimation method is also verified for the different loads and sensor size. It is shown that the results of shape estimation method using the linear matrix well predicts the deflections compared with those of finite element method.