• Title/Summary/Keyword: Sensor Placement

Search Result 149, Processing Time 0.03 seconds

Experiments for the Acoustic Source Localization in 2D Cavity Flow (2차원 공동 유동에서의 소음원 위치 판별을 위한 실험적 연구)

  • Lee, Jaehyung;Park, Kyu-Chol;Choi, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1241-1248
    • /
    • 2004
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone array. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in an anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures and their spectral contents are affected by the cavity parameter L/D.

Optimal Sensor Placement method for Construction of Ubiquitous Sensing Infra (유비쿼터스 센싱 인프라 구축을 위한 최적센서 배치 방법)

  • Kim, Jung-Eun;Yoon, Man-Ki;Han, Jung-Hee;Lee, Chang-Gun;Ha, Eun-Yong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.313-317
    • /
    • 2008
  • 유비쿼터스 환경에 대한 관심이 증폭됨에 따라, 센서는 다양한 어플리케이션들에서 점점 더 많이 사용되고 있다. 이러한 센서 시스템에서, 최소 개의 센서를 가지고 대상 공간이 복수 개의 센서에 의해 완전히 센싱되게 하기 위해서는, 센서를 어디에 배치하느냐가 중요한 문제이다. 또한 복수 개의 센서에 의해 센싱된 데이터로부터 의미 있는 정보를 추출하기 위해서는 센서 서로 간의 거리가 너무 가까워서는 안 된다. (최소거리 요건). 이를 위하여 우리는 TRE-based approach 라고 하는, 최소거리 요건을 만족하며 3-coverage 문제를 해결하는 방법을 제안하며, 이를 기반으로 3-coverage 문제를 3 차원으로 확장시킬 때 가능한 센싱 coverage 모델과 그 확장 가능성에 대해 논의한다.

  • PDF

A Levitation Controller Design for a Magnetic Levitation System (자기부상 시스템의 부상제어기 설계)

  • 김종문;강도현;박민국;최영규
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.6
    • /
    • pp.342-350
    • /
    • 2003
  • In this paper, a levitation controller for a magnetic levitation(MagLev) system is designed and implemented. The target to be controlled is PEM(permanent and electromagnet) type with 4-corners levitation which is open-loop unstable, highly non-linear and time-varying system. The digital control system consists of a VME-based CPU board, AD board, PU board, 4-Quadrant chopper, and gap sensor, accelerometer as feedback sensors. In order to estimate the velocity of the magnet, we used 2nd-order state observer with acceleration and gap signal as input and output, respectively. Using the estimated states, a state feedback control law for the plant is designed and the feedback gains are selected by using the pole-placement method. The designed controller is experimentally validated by step-type gap reference change and force disturbance test.

INSTRUMENTATION AND CONTROL STRATEGIES FOR AN INTEGRAL PRESSURIZED WATER REACTOR

  • UPADHYAYA, BELLE R.;LISH, MATTHEW R.;HINES, J. WESLEY;TARVER, RYAN A.
    • Nuclear Engineering and Technology
    • /
    • v.47 no.2
    • /
    • pp.148-156
    • /
    • 2015
  • Several vendors have recently been actively pursuing the development of integral pressurized water reactors (iPWRs) that range in power levels from small to large reactors. Integral reactors have the features of minimum vessel penetrations, passive heat removal after reactor shutdown, and modular construction that allow fast plant integration and a secure fuel cycle. The features of an integral reactor limit the options for placing control and safety system instruments. The development of instrumentation and control (I&C) strategies for a large 1,000 MWe iPWR is described. Reactor system modeling-which includes reactor core dynamics, primary heat exchanger, and the steam flashing drum-is an important part of I&C development and validation, and thereby consolidates the overall implementation for a large iPWR. The results of simulation models, control development, and instrumentation features illustrate the systematic approach that is applicable to integral light water reactors.

Development of finite element model updating program (유한요소 모델 개선 프로그램 개발)

  • Wang, S.M.;Ko, C.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1633-1640
    • /
    • 2000
  • The finite element analysis (FEA) is widely used in modem structural dynamics because the performance of structure can be predicted in early stage. However, due to the difficult in determination of various uncertain parameters, it is not be easy to obtain a reliable finite element model. To overcome these difficulties, updating program of FE model is developed by consisting of pretest, correlation and updating. In correlation, it calculates modal assurance criteria, cross orthogonality, mixed orthogonality and coordinate modal assurance criteria. For the model updating, the continuum sensitivity analysis and design optimization tool (DOT) are used. The SENSUP program is developed for model updating to obtain physical parameter sensitivity. The developed program is applied to practical examples such as the base plate of HDD, BLDC spindle motor, and upper housing of induction motor. And the sensor placement for the square plate is compared using several methods.

  • PDF

Reviews on innovations and applications in structural health monitoring for infrastructures

  • Li, Hong-Nan;Yi, Ting-Hua;Ren, Liang;Li, Dong-Sheng;Huo, Lin-Sheng
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.1
    • /
    • pp.1-45
    • /
    • 2014
  • The developments and implementations of the structural health monitoring (SHM) system for large infrastructures have been gradually recognized by researchers, engineers and administrative authorities in the last decades. This paper summarizes an updated review on innovations and applications in SHM for infrastructures carried out by researchers at Dalian University of Technology. Invented sensors and data acquisition system are firstly briefly described. And then, some proposed theories and methods including the sensing technology, sensor placement method, signal processing and data fusion, system identification and damage detection are discussed in details. Following those, the activities on the standardization of SHM and several case applications on specific types of structure are reviewed. Finally, existing problems and promising research efforts in the field of SHM are given.

Monitoring of the GMAW Process Using Infra-red Sensor (적외선 센서를 이용한 금속아크 용접 공정 모니터링)

  • 정영재;김일수;박창언;김수광
    • Proceedings of the KWS Conference
    • /
    • 1996.10a
    • /
    • pp.142-144
    • /
    • 1996
  • This paper discusses the application of infra-red thermography in monitoring the robotic arc welding process, and it's potential for weld bead dimension and seam tracking control. Thermal images illustrating weld pool formation dynamics and heat distribution phenomena are digitized and their characteristics are measured. At each sampling point the maximum depth of penetration is recorded together with additional information regarding weld bead placement in relation to the seam location. Deficiencies such as incomplete penetration and lack of side wall fusion are readily identified and can be remained during the process. The technique can help an increase in productivity and weld quality by minimizing the amount of post process rework and inspection efforts needed otherwise.

  • PDF

Acoustic Source Localization in 2D Cavity Flow using a Phased Microphone Array (마이크로폰 어레이를 이용한 2차원 공동 유동에 대한 소음원 규명)

  • 이재형;최종수;박규철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.701-708
    • /
    • 2003
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone way. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures. It is also shown that their spectral contents are affected by the cavity parameter L/D.

  • PDF

The combined deterministic stochastic subspace based system identification in buildings

  • Bakir, Pelin Gundes
    • Structural Engineering and Mechanics
    • /
    • v.38 no.3
    • /
    • pp.315-332
    • /
    • 2011
  • The Combined Deterministic Stochastic Subspace based System Identification Technique (CDSSSIT) is a powerful input-output system identification technique which is known to be always convergent and numerically stable. The technique determines a Kalman state sequence from the projection of the output-input data. The state space matrices are determied subsequently from this Kalman state sequence using least squares. The objective of this paper is to examine the efficiency of the CDSSSIT in identifying the modal parameters (frequencies and mode shapes) of a stiff structure. The results show that the CDSSSIT predicts the modal parameters of stiff buildings quite accurately but is very sensitive to the location of sensors.

Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement (양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석)

  • Park, Cheol-Woo;Park, Young-Hoon;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF