• Title/Summary/Keyword: Sensitivity of metals

Search Result 109, Processing Time 0.028 seconds

Comparison of Matrices for Optimal Analysis of Synthetic Polymers Using MALDI-TOF Mass Spectrometry

  • Yoo, Hee-Jin;Kim, Duck-Hyun;Choi, Yoon-Ji;Choi, Jung Hoon;Park, Moonhee;Shin, DongJin;Oh, YoonSeok;Kim, YangSun;Cho, Kun
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.77-81
    • /
    • 2020
  • Characterization of the various chemical aspects of composite polymers is important for quality control of manufactured polymers. In this study, we compared three suitable matrices (α cyano-4-hydroxycinnamic acid [CHCA], 2,5 dihydroxy benzoic acid [2,5-DHB], and dithranol), to characterize various synthetic polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Although the spectra obtained with the CHCA and 2,5-DHB matrices were generally good, in certain samples ghost peaks disappeared only when dithranol was used as the matrix. Furthermore, we examined the use of sodium trifluoroacetate (NaTFA) as an additive to reduce interference by metals and copolymers in the spectra. In conclusion, appropriate selection of a matrix, according to the characteristics of the polymer, and the use of additives to improve sensitivity are important considerations for polymer analysis and development.

X-Ray Fluorescence Analysis by Stearic Acid-Extraction Technique (스테아르산 추출법에 의한 X-선 형광분석)

  • Tae Sub O;Man Ho Lee;Young Kyu Park
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.1
    • /
    • pp.41-46
    • /
    • 1984
  • To preconcentrate trace elements, microgram amounts of 5 heavy metals (Cu, Co, Ni, Zn and Cd) were precipitated with 8-hydroxyquinoline (oxine) and metal oxinates were extracted with stearic acid. And then each of the molten stearic acid extract with stearic acid. And then each of the molten stearic acid extract was poured into a glass ring and cooled for specimen preparation. The obtained specimens were analyzed by X-ray fluorescene spectrometry. And then conditions of precipitation formation and extraction, reproducibility, sensitivity and detection limit were observed. The relative standard deviation of specimen preparation was 1.0~5.7% and the detection limit was 5~$50{\mu}g$/100ml. The proposed preconcentration procedure exhibited a considerable inhancement and simplicity in preparing specimens.

  • PDF

CO Adsorption and Reaction on Clean and Zn-deposited Au(211) surface

  • Jo, Sang-Wan;Mbuga, F.;Ogasawara, H.;Nilsson, A.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.128.2-128.2
    • /
    • 2013
  • Crucially, effective catalysts must be capable of efficiently catalyzing the protonation of adsorbed CO to adsorbed CHO or COH. One of the strategies is alloying with metals with higher oxygen affinity and Au-Zn alloy is one of the best candidates. At first, we made Au-Zn alloy using vacuum evaporating method. Zn was deposited on the Au(211) surface and the amount was estimated by X-ray photoelectron spectroscopy (XPS) using the relative sensitivity of Au 4f and Zn 3d. We investigated CO adsorption on a clean Au(211) and Au-Zn alloy using temperature-programmed desorption (TPD) and XPS. From the TPD results, we can conclude that the presence of the particular step sites at the Au(211) surface imparts stronger CO bonding and Zn atoms are sitting on the step sites at the Au(211) when Zn is deposited. The XPS results show the oxygen atoms of CO bond Zn atoms on Au-Zn surface. It should be an evidence that alloying Zn atoms that has high oxygen affinity into an electrocatalyst may allow CHO* to bind to the surface through both the carbon and oxygen atoms.

  • PDF

Development of Analytical Techniques for Human Serum and Urine by Using Glow Discharge (글로우 방전을 이용한 혈청과 뇨의 분석기술 개발)

  • Lee, Sang Chun;Choi, Kyung-Soo;Son, Eun-Ho;Sim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.167-173
    • /
    • 1998
  • An electrothermal vaporization-hollow cathode glow discharge-atomic emission spectrometer(ETV-HCGD-AES) has been developed for detecting heavy metals in human serum and urine samples. Fisrt of all, we designed a glow discharge cell for atomic emission spectrometry and its analytical performance was studied with the standard reference materials(SRMs) purchased from the NIST. Practically, the ETV-HCGD-AES demonstrated better instrumental sensitivity and selectivity for detecting Hg and Pb in the SRMs, serum and urine, than ICP-OES since the ETV-HCGD-AES was not required the complicate sample digestion procedure, which improved sample transportation efficiency.

  • PDF

Design of Shear Fracture Specimens for Sheet Metals Using Finite Element Analyses (유한요소해석을 이용한 금속 판재용 전단 파단 시편 설계)

  • C. Kim;H.J. Bong;M.G. Lee
    • Transactions of Materials Processing
    • /
    • v.32 no.2
    • /
    • pp.92-99
    • /
    • 2023
  • In this study, shear fracture specimens are designed using finite element analyses for the characterization of ductile fracture criteria of metal sheets. Many recently suggested ductile fracture criteria require experimental fracture data at the shear stress states in the model parameter identification. However, it is challenging to maintain shear stress states in tension-based specimens from the initial yield to the final fracture, and the loading path can be different for the different materials even with the same shear specimen geometries. To account for this issue, two different shear fracture specimens for low ductility/high ductility metal sheets are designed using the sensitivity tests conducted by finite element simulations. Priorly mechanical properties including the Hosford-Coulomb fracture criterion of the aluminum alloy 7075-T6 and DP590 steel sheets are used in the simulations. The results show that shear stress states are well-maintained until the fracture at the fracture initiation points by optimizing the notch geometries of the shear fracture specimens.

Recent Progress in Membrane based Colorimetric Sensor for Metal Ion Detection (색 변화를 활용한 중금속 이온 검출에 특화된 멤브레인 기반 센서의 최근 연구 개발 동향)

  • Bhang, Saeyun;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.31 no.2
    • /
    • pp.87-100
    • /
    • 2021
  • With a striking increase in the level of contamination and subsequent degradations in the environment, detection and monitoring of contaminants in various sites has become a crucial mission in current society. In this review, we have summarized the current research areas in membrane-based colorimetric sensors for trace detection of various molecules. The researches covered in this summary utilize membranes composed of cellulose fibers as sensing platforms and metal nanoparticles or fluorophores as optical reagents. Displaying decent or excellent sensitivity, most of the developed sensors achieve a significant selectivity in the presence of interfering ions. The physical and chemical properties of cellulose membrane platforms can be customized by changing the synthesis method or type of optical reagent used, allowing a wide range of applications possible. Membrane-based sensors are also portable and have great mechanical properties, which enable on-site detection of contaminants. With such superior qualities, membrane-based sensors examined in the researches were used for versatile purposes including quantification of heavy metals in drinking water, trace detection of toxic antibiotics and heavy metals in environmental water samples. Some of the sensors exhibited additional features like antimicrobial ability and recyclability. Lastly, while most of the sensors aimed for a detection enabled by naked eyes through rapid colour change, many of them investigated further detection methods like fluorescence, UV-vis spectroscopy, and RGB colour intensity.

Variations of Complex Permittivity due to Water Content and Heavy Metal Contamination (함수비와 중금속 오염도에 따른 유전상수의 변화)

  • Oh Myoun-Hak;Kim Yong-Sung;Yoo Dong-Ju;Park Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.231-241
    • /
    • 2005
  • Laboratory experiments were performed to examine the effects of water content and to see if permittivity had sufficient sensitivity to identify subsurface contamination. Both real and imaginary permittivities of unsaturated sand were strongly governed by the volumetric water content. Especially, a linear relationship between real permittivity and volumetric water content was derived at high frequencies (MHz ranges). Heavy metals in pore fluid result in significant increases in the effective imaginary permittivity, due to ionic conduction, but decreases in the real permittivity arises due to the decreased orientational polarization of water molecules caused by hydration of ions. Clear increase in the effective imaginary permittivity with heavy metal concentration was found to be valuable in the application of electrical methods for detecting heavy metals in the subsurface. However, because the permittivity is primarily dependent on the volumetric water content of soil, pre-evaluation on the volumetric water content is required.

X-ray Image Correction Model for Enhanced Foreign Body Detection in Metals (금속 내부의 이물질 검출 향상을 위한 X-ray 영상 보정 모델)

  • Kim, Won
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.15-21
    • /
    • 2019
  • X-rays with shorter wavelengths than ultraviolet light have very good penetration power. It is convergence in industrial and medical fields has been used a lot. n particular, in the industrial field, various researches have been conducted on the detection of foregin body inside metal that can occur in the production process of products such as metal using x-ray, a non-destructive inspection device. Detectors are becoming increasingly popular for the popularization of DR (Digital Radiography) photography methods that digitally acquire X-ray video images. However, there are cases where foreign body detection is impossible depending on the sensor noise and sensitivity inside the detector. When producing a metal product, since the defective rate of the produced product may increase due to contamination of the foreign body, accurate detection is necessary. In this paper, we provide a correction model for X-ray images acquired in order to improve the efficiency of defect detection such as foreign body inside metal. When applied to defect detection in the production process of metal products through the proposed model, it is expected that the detection of product defects can be processed accurately and quickly.

The Effect of Soil Acidification on the Distribution of Nutrients and Heavy metals in Forest Ecosystem near Ulsan Industrial Estate (울산(蔚山) 공단주변(工團周邊) 산림토양(山林土壤)의 산성화(酸性化)가 산림생태계(山林生態系)의 양료(養料)와 중금속(重金屬) 분포(分布)에 미치는 영향(影響))

  • Lee, Seung Woo;Lee, Soo Wook
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.3
    • /
    • pp.286-298
    • /
    • 1995
  • This study was carried out to investigate the effect of forest soil acidification on the distribution of exchangeable cations($Ca^{2+}$, $Mg^{2+}$, $Al^{3+}$) and heavy metals(Cu, Zn, Mn, Pb, Cd) in soil, and to understand the relation of the soil chemical properties and the distribution of nutrients and hear metals in fine root and foliage. The results through survey on the long - term change of soil pH and the contents of nutrient and heavy metal in soil, fine root and foliage by 2 sites near Ulsan - Onsan industrial estate and 2 sites in limited development district are summarized as follows : 1. The average forest soil pH(A horizon) in Ulsan had been proceeded down to 3.73 in deciduous forest and 3.86 in coniferous forest in 1994 from 4.45 and 4.78 in 1987, respectively, which indicated serious soil acidification. As comparing soil pH among sites, Dongcheon coniferous forest(pH 4.57) in limited development district showed the highest values and Dangwol deciduous forest(pH 3.19) near Onsan industrial estate showed the lowest values in 1994. 2. Contents of exchangeable calcium in forest soils of limited development district where showed much higher soil pH than industrial estate were 3.5 times more in deciduous forest soil and 11 times more in coniferous forest soil than in industrial estate, and contents of exchangeable magnesium were also 4.5 and 5 times more in limited development district than in industrial estate, respectively. However contents of exchangeable aluminium which had been supposed more in forest soil of industrial estate were more in limited development district. 3. Contents of calcium and magnesium in fine root of deciduous trees(A hirsuta. Q. acutissima) were 3.6 and 1.7 times more in limited development district than in industrial estate, respectively, and those of coniferous trees(P. rigida, P. thunbergii) were 4.6 and 1.5 times more in Limited development district than in industrial estate, respectively. Also contents of calcium and magnesium in foliage of deciduous trees were 1.1 and 2.2 times more in limited development district than in industrial estate, respectively, and those of coniferous trees were 1.8 and 3.3 times more in limited development district, respectively. And contents of aluminium in fine root and foliage were nearly as same as in soil. 4. Ca/Al molar ratios in soil and fine root, which could be related with the dgree of soil acidification and Al toxicity on trees, were Less than 1 in all sites except Dongcheon, suggesting that the soil and fine root in the sites have high sensitivity to soil acidification and the decrease in nutrient uptake and root enlargement. The Ca/Al molar ratios in soil and fine root in coniferous forest were highly correlated with the soil pH one another. 5. Contents of Cu, Zn and Pb in soil, fine root and foliage were more in industrial estate than in limited development district in both deciduous and coniferous forests, however, oppositely contents of Mn and Cd in soil were more in limited development district than in industrial estate.

  • PDF

Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension (금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량)

  • Han, Chul-Woo;In, Gyo;Choi, Jong-Moon;Kim, Sun Tae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.608-615
    • /
    • 2000
  • A determination method of trace nickel and cobalt in water samples was studied and developed by adsorbing their complexes on ion exchange resin suspension. The analytical ions were formed as complexes with a ligand of APDC (ammonium pyrrolidinedithiocarbamate) and adsorbed on anion exchange resin of Dowex 2-X8. After the suspension was filtered out with membrane filter, the complexes were dissolved in HCl solution by an ultrasonic vibrator for ET-AAS determination. Several conditions were optimized as followings. pH of sample solution: 5.0, amount of ligand APDC: more than 430 times in mole ratio, the type and concentration of acid: 0.1 M HCl, and vibration time: 7 minutes. The addition of palladium in the HCl solution could improve the reproducibility and sensitivity by a matrix modification in the absorbance measurement. This procedure was applied for the analysis of three kinds of real water samples. The detection limits equivalent to 3 times standard deviation of blank were Co 0.36 ng/mL and Ni 0.27 ng/mL and recoveries in spiked samples were 99-102% for cobalt and 100-105% for nickel.

  • PDF