• Title/Summary/Keyword: Sensitive Equipment

Search Result 246, Processing Time 0.041 seconds

A Study on Design and Operation Performance of Automatic Fire Detection Equipment (P-type One-class Receiver) by Bidirectional Communication (양방향 통신이 가능한 자동화재탐지설비(P형 1급 수신기)의 설계 및 동작특성에 관한 연구)

  • Lee, Bong-Seob;Kwak, Dong-Kurl;Jung, Do-Young;Cheon, Dong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.347-353
    • /
    • 2012
  • In this paper, authors will develop the quick and precise remote controller of automatic fire detection equipment (P-type one-class receiver) based on information communication technology (IT). The remote controller detects the fire and disaster in the building automatically and quickly and then activates the facilities to extinguish the fire and disaster, monitoring such situation in a real time through wire-wireless communication network. The proposed remote controller is applied a programmable logic device (PLD) micom. of one-chip type which is small size and lightweight and also has highly sensitive-precise reliabilities. The one-chip type PLD micom. analyzes digital signals from sensors, then activates fire extinguishing facilities for alarm and rapid suppression in a case of fire and disaster. The detected data is also transferred to a remote situation room through wire-wireless network of RS232c and bluetooth communication, and then the situation room sends an emergency alarm signal. The automatic fire detection equipment (AFDE) based on IT will minimize the life and wealth loss while prevents fire and disaster.

Implementation and Test of GPS Jamming Monitoring Equipment (GPS 교란 감시 장치 구현 및 시험)

  • Joo, Inone;Lee, Jeom Hun;Lee, Sanguk;Kim, Jaehoon
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.95-99
    • /
    • 2013
  • GPS service is generally being used in the navigation application such as the car navigation and the smart phone. Recently, GPS service continues to increase in the timing application such as the mobile telecommunication network, the smart grid, and the financial network. As GPS signals are sensitive to GPS jamming, it should be monitored and protected. In oder to prevent and minimize the damage caused by GPS jamming, many countries are developing and operating GPS jamming monitoring system. This paper presents the implementation and the test results of the GPS jamming equipment which provides the detection, the direction finding and the location of GPS jamming.

A novel risk assessment approach for data center structures

  • Cicek, Kubilay;Sari, Ali
    • Earthquakes and Structures
    • /
    • v.19 no.6
    • /
    • pp.471-484
    • /
    • 2020
  • Previous earthquakes show that, structural safety evaluations should include the evaluation of nonstructural components. Failure of nonstructural components can affect the operational capacity of critical facilities, such as hospitals and fire stations, which can cause an increase in number of deaths. Additionally, failure of nonstructural components may result in economic, architectural, and historical losses of community. Accelerations and random vibrations must be under the predefined limitations in structures with high technological equipment, data centers in this case. Failure of server equipment and anchored server racks are investigated in this study. A probabilistic study is completed for a low-rise rigid sample structure. The structure is investigated in two versions, (i) conventional fixed-based structure and (ii) with a base isolation system. Seismic hazard assessment is completed for the selected site. Monte Carlo simulations are generated with selected parameters. Uncertainties in both structural parameters and mechanical properties of isolation system are included in simulations. Anchorage failure and vibration failures are investigated. Different methods to generate fragility curves are used. The site-specific annual hazard curve is used to generate risk curves for two different structures. A risk matrix is proposed for the design of data centers. Results show that base isolation systems reduce the failure probability significantly in higher floors. It was also understood that, base isolation systems are highly sensitive to earthquake characteristics rather than variability in structural and mechanical properties, in terms of accelerations. Another outcome is that code-provided anchorage failure limitations are more vulnerable than the random vibration failure limitations of server equipment.

A New Technique for Burst Cartridge Detection

  • Hyun, Kyung-Ho
    • Nuclear Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.5-16
    • /
    • 1969
  • A design of new burst cartridge detection system for gas-cooled power reactor using a spherical sampling chamber with negative electrode is presented. The results of theoretical calculation indicate that the designed system is feasible for a practical application and sensitive enough to detect a 1 $\textrm{cm}^2$ hole in the fuel clad-ding.

  • PDF

Vibration Characteristics of Low-Vibration RC Floor Structures (저진동 RC 플로어 구조의 진동특성에 관한 연구)

  • Kim, Jin-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.510-513
    • /
    • 2006
  • Due to the location of vibration sensitive equipment on the floor, it is necessary for its vibration performance to be maintained within stringent limits, resulting in a design of higher mass and stiffness than would be usual for a floor of this type. Modal testing is conducted on the floor to obtain their dynamic characteristics. A considerable level of vibration transmission is observed by comparing the ratio of simulated transfer and point mobility FRFs of the floor.

  • PDF

The Design using the reluctance of Reluctive Pressure Transducer (릴럭턴스를 이용한 Reluctive Pressure Transducer의 설계)

  • 조항신;박희성;주형준;성세진;이기홍
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.328-331
    • /
    • 1998
  • Because of the powerful tolerance of overload, dynamic response and anti-erosion, Reluctive Pressure Transducer(RPT), as a measuring element of oil pressure equipment is applied to the measuring system of vessels, air craft. The Electrical reluctance appeared in the pressed diaphragm. To process the reluctance as a electric signal, bridge circuit is used. The design using the reluctance of pressure sensor is described in this paper. For the high efficiency of the sensitive RPT, pressure sensor structure is presented and electrical signal processing is simulated.

  • PDF

The Review of Specification for SPDs used in Railway Signalling Equipment (철도신호설비용 서지보호기에 대한 규격 검토)

  • Lee, Tae-Hoon;Park, Ki-Bum;Jeon, Yong-Joo;Ryu, Young-Tae
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.596-602
    • /
    • 2008
  • Recently, there are increasing social needs for safe operation of trains and comforting for passengers. But lightning surges are responsible for serious disturbances such as damage, permanent degradation or temporary erratic operation of sensitive electronics circuits and systems. The purpose of this paper is to identify the requirements for Surge Protective Devices(SPDs) used in protecting railway signalling system. In this paper, we describes tests and requirements which establish methods for testing SPDs and determining their performance.

  • PDF

A Study of the Mitigating Effect Comparison of Voltage Sags by WTG Types Based on the Concept of Area of Vulnerability (타입별 풍력 발전기 설치에 따른 민감 부하의 순간전압강하 저감 효과 비교 분석 연구)

  • Park, Se-Jun;Yoon, Min-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1682-1688
    • /
    • 2017
  • In modern society, the number of industrial customers using equipment sensitive particularly to voltage sags is rapidly increasing. As voltage sags can cause loss of information as well as false operation of the control device, it results in the vast economic damage in industrial processes. One way to mitigate voltage sags in the sensitive loads is the installation of distributed generation (DGs) on the periphery of these loads. In addition, renewable energy sources are currently in the spot light as the potential solution for the energy crisis and environmental issues. In particular, wind power generation which is connected to a grid is rising rapidly because it is energy efficient and also economically feasible compared to other renewable energy sources. On the basis of the above information, in this paper, with Wind Turbine Generators (WTGs) installed nearby the sensitive load, the analysis of the mitigating effect comparison by types of WTGs is performed using voltage sag assessment on the IEEE-30 bus test system. That is, the areas of vulnerability according to types of WTGs are expected to be different by how much reactive power is produced or consumed as WTG reactive power capability is related to the types of WTGs. Using the concept of 'Vulnerable area' with the failure rate for buses and lines, the annual number of voltage sags at the sensitive load with the installation of WTGs per type is studied. This research will be anticipated to be useful data when determining the interconnection of wind power generation in the power system with the consideration of voltage sags.

A Study on the Decision Vibration Criteria & Dynamic Stiffness Criteria of the Vibration Sensitive Equipment (정밀 장비의 진동 및 동강성 허용규제치의 결정을 위한 연구)

  • Kim, Joo-Young;Lee, Gyu-Seop;Baek, Jae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.423-423
    • /
    • 2009
  • 미진동 제어라는 분야에 대한 연구는 반도체 산업이 초고도화 및 초정밀화가 진전되고 있는 최근에 들어와 학계보다는 전문 반도체와 TFT-LCD의 미진동제어 관련 엔지니어 그룹과 정밀 장비 제작사를 중심으로 이루어져왔다. 고집적 생산 제품을 가공 및 검사하기 위해서는 가공 선폭 이상의 분해 성능을 가진 고정밀도의 생산 및 검사 장비가 필요하다. 이런 고정밀도 생산 및 검사장비는 내외부로부터 입력되는 진동에 민감한 영향을 받는다. 초기 반도체 산업을 주도한 미국을 중심으로 일부 학자와 반도체 진동 제어를 수행하는 전문연구소에서 작성한 BBN-Criteria는 정밀장비의 용도나 분해능 별로 정리된 진동허용규제치를 지침서로 사용하여 왔다. 그러나 장비의 엄밀한 주파수 특성 및 정밀도 측면에서 불확실한 영역부분을 가지고 있기 때문에 미소한 진동을 제어하는 구조 설계자 관점에서는 불충분한 자료이다. 그리고 주파수 분해능을 가진 진동허용규제치를 제시하는 것이 바람직하지만 대부분의 제작사에서는 그렇지 못하고 있다. 그런 이유에는 장비 개개의 진동허용규제치가 다른 고가의 장비 전량에 대하여 시험을 수행해야 하는 점, 가진(加振)특성, 중량, 크기 등의 진동실험 자체에 어려움 때문이다. 또한 진동실험시 가진주파수의 분해능의 결려에 따른 장비의 동적 특성이 고려되지 않은 불확실한 영역 부분을 포함한 진동허용규제치를 제시함으로서 불확실한 영역부분의 진동 하한치를 진동허용규제치의 상한치로 결정하는 문제로 인하여 진동허용규제치가 더욱 가혹하게 제시되어 건물 구조 설계와 방진의 어려움을 가중시킬 여지가 있다. 본 논문에서는 이런 어려움 등을 회피하는 방법으로 주파수응답함수(Frequency Response Function, FRF)를 이용하여 정밀장비의 진동허용규제치를 결정하는 간편하면서도 더욱 정밀한 새로운 방법을 모색하였다.

  • PDF

Design and control of extractive distillation for the separation of methyl acetate-methanol-water

  • Wang, Honghai;Ji, Pengyu;Cao, Huibin;Su, Weiyi;Li, Chunli
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2336-2347
    • /
    • 2018
  • The azeotrope of methyl acetate methanol and water was isolated using extractive distillation with water as entrainer. The pressure-swing extractive distillation (PSED) process and vapor side-stream distillation column (VSDC) with the rectifier process were designed to separate the methyl acetate, methanol and water mixture. It was revealed that the VSDC with the rectifier process had a reduction in energy consumption than the PSED process. Four control schemes of the two process were investigated: Double temperature control scheme (CS1), $Q_R/F$ feedforward control of reboiler duty scheme for PESD (CS2), $Q_R/F$ feedback control scheme for VSDC (CS3), the feedback control scheme of sensitive plate temperature of side-drawing distillation column to dominate the compressor shaft speed (CS4). Feed flow and composition disturbance were used to evaluate the dynamic performance. As a result, CS4 is a preferable choice for separation of methyl acetate-methanol-water mixture. A control scheme combining the operating parameters of dynamic equipment with the control indicators of static equipment was proposed in this paper. It means using the sensitive plate temperature of side-drawing column to control the compressor shaft speed. This is a new control scheme for extractive distillation.