• Title/Summary/Keyword: Sensitive Equipment

Search Result 246, Processing Time 0.026 seconds

Tilt analysis of optical pickup actuator using coupled fields analysis (연성해석을 이용한 광픽업 구동기 경사 해석)

  • 신창훈;김철진;이경택;박노철;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.684-687
    • /
    • 2002
  • In optical disk drive(ODD), pickup actuator, which comprises a key part of an optical disk drive equipment. must be thin. compact, and high sensitive. Low tilt is also an important requirement for the actuator, since optical disks are to high density. This tilt occurs from around the axis parallel to the tangential and radial direction of the disk. The main reason of the moment is the coupling effect between focus driving system and tracking driving system. This paper analyzed tut quantity due to focusing and tracking force through coupled fields analysts with electromagnetic analysis and structural analysis.

  • PDF

A evaluation and countermeasure for blast-induced vibration of micro electronic production facility based on experimental method (실험적 방법에 의한 발파작업으로 기인하는 인접 초정밀 생산장비 FAB에 미치는 진동 영향성 평가 및 제어대책)

  • Son, Sung-Wan;Park, Sang-Gon;Lee, Hong-Ki;Chun, Jong-Kun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.875-878
    • /
    • 2006
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function, therefore, it is very important to predict precisely vibration environment of microelectronics production facility due to adjacent blast work. However, it is not easy to evaluate a quantitative vibration response of structure due blast because it can be determined by the characteristics of vibration sources, propagation through rock and soil and dynamic properties of building. In this paper, vibration influence evaluation of micro-electronic Production building induced from adjacent blast activity was performed by real measurement data obtained on ground and structure at same time. And blast vibration allowable limit on ground was supposed by measurement data analysis in order to avoid operation error of precision equipments

  • PDF

LQG design scheme for multiple vibration controllers in a data center facility

  • Kohiyama, Masayuki;Yoshida, Minako
    • Earthquakes and Structures
    • /
    • v.6 no.3
    • /
    • pp.281-300
    • /
    • 2014
  • This study proposes a scheme to design control parameters for a data center facility with a vibration controller on its top floor and a secondary isolation device with its own vibration controller designed to protect vibration-sensitive computer equipment. The aim is to reduce the effects of acceleration and drift from an earthquake on computer servers placed on the isolation device that must operate during a seismic event. A linear elastic model is constructed and the evaluation function of the linear quadratic Gaussian (LQG) control is formulated. The relationship between the control parameters and the responses is examined, and based on the observations, a control parameter design scheme is constructed to reduce the responses of both the building and the computer server effectively.

반도체 제조공정 중 발생하는 오염입자 측정에 관한 연구

  • Na Jeong-Gil;Kim Tae-Seong
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.145-149
    • /
    • 2006
  • As the minimum feature size decreases, it is more difficult to control critical contaminant particles. For 16GB flash memory introduced by Samsung a few months ago, 50nm process was used and in this case, contaminant particles as small as 25nm should be control led. The particle beam mass spectrometer (PBMS) was developed to directly sample particles at pressures down to 100 mtorr. This instrument is sensitive to small particles (>5nm) produced in low concentrations ($>20cm^{-3}$). The PBMS has proved to be effect ive in measuring particles generated during semi-conductor fabrication processes, such as low-pressure chemical vapor deposition (LPCVD) of thin films. The operating principle of the PBMS and some measurement results are reviewed in this paper.

  • PDF

Quantitative Evaluation of the Customers' Effect by Automatic Reclosing of Power Distribution System (배전시스템에서의 재폐로에 의한 수용가측 영향의 정량적 평가)

  • 임성정;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.2
    • /
    • pp.7-14
    • /
    • 1998
  • This paper presents an approach to quantitatively evaluate customers' effect due to automatic reclosing of power distribution systems. This proposed approach assess the customers' effect on equip ment halt by predicting a momentary interruption and voltage sag and analyzing the impact of customers' equipment sensitive to electric disturbances. Simulation results show that the increment of the number of reclosing improves the service reliability, but deteriorates the power quality for customers. The proposed approach utilizes the determination of automatic reclosing scheme and distribution system planning.anning.

  • PDF

Modeling of Indium Tin Oxide(ITO) Film Deposition Process using Neural Network (신경회로망을 이용한 ITO 박막 성장 공정의 모형화)

  • Min, Chul-Hong;Park, Sung-Jin;Yoon, Neung-Goo;Kim, Tae-Seon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.9
    • /
    • pp.741-746
    • /
    • 2009
  • Compare to conventional Indium Tin Oxide (ITO) film deposition methods, cesium assisted sputtering method has been shown superior electrical, mechanical, and optical film properties. However, it is not easy to use cesium assisted sputtering method since ITO film properties are very sensitive to Cesium assisted equipment condition but their mechanism is not yet clearly defined physically or mathematically. Therefore, to optimize deposited ITO film characteristics, development of accurate and reliable process model is essential. For this, in this work, we developed ITO film deposition process model using neural networks and design of experiment (DOE). Developed model prediction results are compared with conventional statistical regression model and developed neural process model has been shown superior prediction results on modeling of ITO film thickness, sheet resistance, and transmittance characteristics.

Embodiment of Firewall Block for Safety in the Cave (동굴 공간의 안전과 방재차단벽)

  • Kim, Bo-Su;Kim, Kang-Won;Kim, Tae-Hwan;Park, Jung-Ho;Lee, Yung-Jae;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.87
    • /
    • pp.8-13
    • /
    • 2008
  • The automatic firewall block and fire alarm system was embodied by using gas circuit and wireless communication equipment, using a smoke sensor (ST-QA1A) and RF Module. OR-CAD was also used for testing circuit system and experiment circuit after assembling circuit. As a result in experiment, the gas sensor detected well an imaginary smoke and worked reliably for driving action of firewall block motor and wireless warning alarm. Through the smoke sensitive perception from the fire, the warning alarm and the preventing fire propagation from the specific closed region were verified reliably. The gas sensor and RF module for firewall and fire alarm system were actually available.

Effect of thermal gradients on stress/strain distributions in a thin circular symmetric plate

  • Aleksandrova, Nelli N.
    • Structural Engineering and Mechanics
    • /
    • v.58 no.4
    • /
    • pp.627-639
    • /
    • 2016
  • The analysis of thermally induced stresses in engineering structures is a very important and necessary task with respect to design and modeling of pressurized containers, heat exchangers, aircrafts segments, etc. to prevent them from failure and improve working conditions. So, the purpose of this study is to investigate elasto-plastic thermal stresses and deformations in a thin annular plate embedded into rigid container. To this end, analytical research devoted to mathematically and physically rigorous stress/strain analysis is performed. In order to evaluate the effect of logarithmic thermal gradients, commonly applied to structures which incorporate thin plate geometries, different thermal parameters such as temperature mismatch and varying constraint temperature were introduced into the model of elastic perfectly-plastic annular plate obeying the von Mises yield criterion with its associated flow rule. The results obtained may be used in sensitive to temperature differences aircraft structures where the thermal effects on equipment must be kept in mind.

Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method (Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer) 개발)

  • Jeong, Jong-Kyou;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1954-1961
    • /
    • 2009
  • This paper describes the development of a three-phase line-interactive dynamic voltage restorer with hybrid detection method, which is composed of three H-bridge inverter modules and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 3kVA prototype. The developed system can compensate the input voltage sag and interruption within 2ms. The maximum allowable duration of voltage interruption is about 4 seconds. The developed system can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication devices, and automation devices, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components, and to be highly reliable in operation.

A Study on the Algorithm for Detection of Partial Discharge in G15 Using Wavelet Transform (웨이브렛 변환을 이용한 GIS의 부분방전 검출 알고리즘에 관한 연구)

  • 강진수;김철환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.25-34
    • /
    • 2003
  • Gas insulated switchgear(GIS) is an important equipment in a substation. It is highly desirable to measure a partial discharge(PD) in GIS which is a symptom before insulation breakdown occurs. The issue is that the PD signal is weak and sensitive to external noise. In this paper, the algorithm for detection of PD in GIS using wavelet transform is proposed. The wavelet transform provides a direct quantitative measure of spectral content, "dynamic spectrum", in the time-frequency domain. The recommended mother wavelet is 'Daubechies' wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, can be used most properly in disturbance phenomena which occurs rapidly for a short time. Through the procedure of wavelet transform, noise extraction and reconstruction, the signal is Analyzed to determine the magnitude of PD in GIS. In experimental results, we can know that partial discharge is exactly detected in combination of Dl and D2 using wavelet transform.transform.