• 제목/요약/키워드: Semi-industrial Area

검색결과 62건 처리시간 0.027초

준 실시간 화학적 조성자료를 이용한 미세입자 연무 에피소드 규명 (Investigation on a Haze Episode of Fine Particulate Matter using Semi-continuous Chemical Composition Data)

  • 박승식;김선정;공부주;이권호;조석연;김종춘;이석조
    • 한국대기환경학회지
    • /
    • 제29권5호
    • /
    • pp.642-655
    • /
    • 2013
  • In this study, semi-continuous measurements of $PM_{2.5}$ mass, organic and elemental carbon (OC and EC), black carbon (BC), and ionic species concentrations were made for the period of April 03~13, 2012, at a South Area Supersite at Gwangju. Possible sources causing the high concentrations of major chemical species in $PM_{2.5}$ observed during a haze episode were investigated. The measurement results, along with meteorological parameters, gaseous pollutants data, air mass back trajectory analyses and PSCF (potential source contribution function) results, were used to study the haze episode. Substantial enhancements of OC, EC, BC, $K^+$, $SO{_4}^{2-}$, $NO{_3}{^-}$, $NH{_4}{^+}$, and CO concentrations were closely associated with air masses coming from regions of forest fires in southeastern China, suggesting likely an impact of the forest fires. Also the PSCF maps for EC, OC, $SO{_4}^{2-}$, and $K^+$ demonstrate further that the long-range transport of smoke plumes of forest fires detected over the southeastern China could be a possible source of haze phenomena observed at the site. Another possible source leading to haze formation was likely from photochemistry of precursor gases such as volatile organic compounds, $SO_2$, and $NO_2$, resulting in accumulation of secondary organic aerosol, $SO{_4}^{2-}$ and $NO{_3}{^-}$. Throughout the episode, local wind directions were between 200 and $230^{\circ}C$, where two industrial areas are situated, with moderate wind speeds of 3~5 m/s, resulting in highly elevated concentration of $SO_2$ with a maximum of 15 ppb. The $SO{_4}^{2-}$ peak occurring in the afternoon hours coincided with maximum ambient temperature ($24^{\circ}C$) and ozone concentration (~100 ppb), and were driven by photochemistry of $SO_2$. As a result, the pattern of $SO{_4}^{2-}$ variations in relation to wind direction, $SO_2$ and $O_3$ concentrations, and the strong correlation between $SO_2$ and $SO{_4}^{2-}$ ($R^2=0.76$) suggests that in addition to the impact of smoke plumes from forest fires in the southeastern China, local $SO_2$ emissions were likely an important source of $SO{_4}^{2-}$ leading to haze formation at the site.

반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(II) -구조개선을 중심으로 (A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter(II) -Structural Improvement)

  • 김진욱;정유진;유정근;손병현
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.985-992
    • /
    • 2011
  • 복합 후처리장치의 최적 모델 개발을 위해 반응기 내부 유동 특성 및 유량 분배 수준 등과 관련지어 3차원 전산유체역학(CFD)을 수행하였다. 백필터의 각 격실별로 유량 분배가 크게 차이가 발생해 반건식 반응기(SDR)에 편류현상이 발생할 것으로 예측되어 백필터에 균등한 유량 분배를 위한 구조 개선이 시급한 것으로 나타났다. 이를 위해, 장치에 3가지 수정.보완(플래넘 구조 개선, 풍도 오리피스 설치, 복수의 흡인 덕트 설치)이 이루어졌다. 이 중에서 플래넘 구조 개선, 풍도 오리피스 설치가 가장 합리적일 것으로 판단된다. 본 해석을 이용하여 수정 보완한 배가스복합 후처리장치는, 반건식 반응기와 백필터 처리부가 일체화되어 있어 장치가 콤팩트하고 설치면적이 적으며 운영 및 관리가 매우 편리할 것으로 판단된다.

반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(I) (A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter)

  • 권영현;김진욱;정유진;김민철;이재정;이강우;손병현
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4656-4663
    • /
    • 2010
  • 본 연구에서는 복합 후처리장치의 최적 모델 개발을 위해 반응기 내부 유동 특성 및 유량 분배 수준, 공기 연령, 체류시간 등과 관련지어 3차원 전산유체역학(CFD)을 수행하였다. 백필터의 각 격실별로 유량 분배가 크게 차이가 발생해 반건식 반응기(SDR)에 편류현상이 발생할 것으로 예측되어 백필터에 균등한 유량 분배를 위한 구조 개선이 시급한 것으로 나타났다. 또한 SDR의 유입구 구조 변경을 통해 반응기 내부의 속도장과 체류시간 분포 특성을 개선할 수 있는 것으로 나타났다. 본 해석을 이용하여 수정 보완한 배가스 복합 후처리장치는, 반건식 반응기와 백필터 처리부가 일체화되어 있어 장치가 콤팩트하고 설치면적이 적으며 운영 및 관리가 매우 편리할 것으로 판단된다.

PMF 모델을 이용한 수도권 내 3개 도시에서의 PM10 오염원의 기여도 추정 (Estimation of PM10 Source Contributions on Three Cities in the Metropolitan Area by Using PMF Model)

  • 이태정;허종배;이승묵;김신도;김동술
    • 한국대기환경학회지
    • /
    • 제25권4호
    • /
    • pp.275-288
    • /
    • 2009
  • The Korean government strengthened the environmental polices to manage and enhance Metropolitan Area air quality, and also has enforced "Special Act on Seoul Metropolitan Air Quality Improvement (SASMAQI)" issued in Dec. 2004. Recently government expanded the Seoul Metropolitan Air Quality Management District (SMAQMD) to the outskirts satellite cities of Seoul area through the "Revised Law Draft of SASMAQI". The SMAQMD has been alloted the allowable emission loads to the local governments on the basis of the carrying $PM_{10}$ capacity. However, in order to establish the effective air quality control strategy for $PM_{10}$, it is necessary to understand the corresponding sources which have a potential to directly impact ambient $PM_{10}$ concentration. To deal with the situations, many receptor methodologies have been developed to identify the origins of pollutants and to determine the contributions of sources of interests. The objective of this study was to extensively identify $PM_{10}$ sources and to estimate their contributions at the metropolitan area. $PM_{10}$ samples were simultaneously collected at the 3 semi-industrialized local cities in the Seoul metropolitan area such as Hwasung-si, Paju-si, and Icheon-si sites from April 15 to May 31, 2007. The samples collected on the teflon membrane filter by one $PM_{10}$ cyclone sampler were analyzed for trace metals and soluble ions and samples on the quartz fiber filter by another sampler were analyzed for OC and EC. Source apportionment study was then performed by using a positive matrix factorization (PMF) receptor model. A total of 6 sources were identified and their contributions were estimated in each monitoring site. Contribution results on Hwasung, Paju, and Icheon sites were as follows: 33%, 27%, and 27% from soil source, 26%, 26%, and 21% from secondary aerosol source, 11%, 11%, and 12% from biomass burning, 12%, 6%, and 5% from sea salt, 7%, 15%, and 19% from industrial related source, and finally 11%, 15%, and 16% from mobile and oil complex source, respectively. This study provides information on the major sources affecting air quality in the receptor sites and thus it will help to manage the ambient air quality in the metropolitan area by establishing reasonable control strategies, especially for the anthropogenic emission sources.

비접촉 전원공급 시 2차측 코일 제작을 줄이기 위한 2차측 정류부 효율 개선에 관한 연구 (An Efficiency Improvement of Secondary-Side Rectifier for Minimizing 2nd Coil-Making in Contact-less Power Supply)

  • 유주희;김춘삼;성원기
    • 한국산학기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.1302-1307
    • /
    • 2011
  • 본 논문은 코일 제작 시 고려사항인 1, 2차측 코일 인덕턴스, 턴수, 크기, 두께, 차폐지 등을 고려하여 리쯔 와이어로 나선형 코일을 제작하는데 이때 반자동화 권선기를 사용하게 된다. 1, 2차측 코일 사양을 정하여 코일을 제작할 때 다양한 사양의 리쯔 와이어와 나선형 코일을 필요로 하게 되는데, 이때 제작 비용, 기간, 제작 시 발생하는 불량 등으로 인해 코일 샘플 제작에 어려움이 발생하고 원하는 사양의 코일 품질 관리에도 어려움이 생기게 된다. 이를 개선하기 위해 2차측의 정류부를 개선함으로써 코일 설계 및 제작 시 다양한 코일 제작 사양의 범위를 좀더 포괄적으로 할 수 있으며 제작 시 발생하는 비용을 줄이고, 기간 단축 및 코일의 품질 관리를 개선하고자 한다.

Modified Pharmacokinetic/Pharmacodynamic model for electrically activated silver-titanium implant system

  • Tan, Zhuo;Orndorff, Paul E.;Shirwaiker, Rohan A.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권3호
    • /
    • pp.127-141
    • /
    • 2015
  • Silver-based systems activated by low intensity direct current continue to be investigated as an alternative antimicrobial for infection prophylaxis and treatment. However there has been limited research on the quantitative characterization of the antimicrobial efficacy of such systems. The objective of this study was to develop a semi-mechanistic pharmacokinetic/pharmacodynamic (PK/PD) model providing the quantitative relationship between the critical system parameters and the degree of antimicrobial efficacy. First, time-kill curves were experimentally established for a strain of Staphylococcus aureus in a nutrientrich fluid environment over 48 hours. Based on these curves, a modified PK/PD model was developed with two components: a growing silver-susceptible bacterial population and a depreciating bactericidal process. The test of goodness-of-fit showed that the model was robust and had good predictability ($R^2>0.7$). The model demonstrated that the current intensity was positively correlated to the initial killing rate and the bactericidal fatigue rate of the system while the anode surface area was negatively correlated to the fatigue rate. The model also allowed the determination of the effective range of these two parameters within which the system has significant antimicrobial efficacy. In conclusion, the modified PK/PD model successfully described bacterial growth and killing kinetics when the bacteria were exposed to the electrically activated silver-titanium implant system. This modeling approach as well as the model itself can also potentially contribute to the development of optimal design strategies for other similar antimicrobial systems.

제4차 산업혁명 시대의 환경변화와 중소규모 기업의 전략적 대응 우선순위 (A Study on the Environmental Changes in the 4th Industrial Revolution Era and the Strategic Response Priority of SMEs)

  • 손승희
    • 중소기업연구
    • /
    • 제41권3호
    • /
    • pp.151-172
    • /
    • 2019
  • 제4차 산업혁명이라는 시대적 변화는 특정 분야에 국한되지 않고 사회 및 전 산업분야에 영향을 미치며 모든 기업들에 변화에 대한 효과적인 대응을 요구하고 있다. 기업들은 생존을 넘어 지속적인 성장발전을 위해서 빅데이터나 인공지능과 같은 첨단 정보통신기술을 도입하거나, 효율적이고 체계적인 조직구조 개선 및 조직문화 쇄신, 혹은 업무효율화와 구성원 개개인의 역량을 강화하는 등의 다양한 모습으로 대응하고 있다. 본 연구는 제4차 산업혁명과 같은 다차원적인 변화에의 대응은 획일적이어서는 안 되며, 기업 특성에 따라 대응전략과 대응 우선순위가 달라야한다는 가정 하에 출발하였다. 본 연구의 목적은, 효율적이고 체계적인 조직구조는 물론 성숙된 조직문화 그리고 정보시스템 도입을 위해서 필요한 기술기반구조를 갖추고 있는 대규모 기업들과 달리 중소규모 기업(소기업과 소상공인 포함)의 차별화된 대응전략과 대응요인(영역)들의 우선순위를 제시하는데 있다. 선행연구를 통해서 밝혀진 대응요인(영역)들에 대해서 세미델파이방식의 반복 설문을 통해서 데이터를 수집하였으며, 데이터 분석결과, 중규모 기업의 경우에는 정보기술도입 > 조직구성원의 역량강화 > 기술기반구조 구축 > 조직구조 개선 > 업무효율화 > 조직문화 개선 순으로 나타났으며, 소상공 및 자영업을 포함한 소규모기업의 경우에는, 조직구성원의 역량강화 > 업무효율화 > 정보기술 도입 > 기술기반구조 구축 > 조직구조 개선 > 조직문화 개선 순으로 나타났다. 본 연구결과 도출된 중소규모 기업의 대응 우선순위는 중소규모 기업이 제4차 산업혁명 시대의 변화에 대응전략을 수립하는데 실제적인 활용효과가 있을 것으로 기대된다.

환경기술과 정보기술 기반의 미래도시 공간 메커니즘과 알고리즘 분석 (An Analysis on the Mechanism and Algorism of ET·IT Based Future City Space)

  • 한주형;이상호
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.296-305
    • /
    • 2017
  • 본 연구는 정보기술과 환경기술의 미래도시 메커니즘(Mechanism) 구조와 그에 따른 알고리즘 분석을 통해 새로운 도시의 공간을 창출하는데 목표가 있다. 본 연구의 결과는 다음과 같다. 첫째, 환경과 정보기술의 개발트렌드는 친환경개발, 에너지개발, 에너지 절감기술 개발, 광역네트워크 개발 등 4가지 유형으로 분류 할 수 있다. 둘째, 사례 상암DMC는 한국전쟁부터 1978년까지 친환경과 환경 보호적 측면에서 개발이 진행되었다. 광역네트워크 개발은 1990년부터 2000년 사이에 급속하게 진화되었다. 그러나 2010년 이후 도시공간은 다시 환경과 정보의 융합에 의해 공간이 개발되고 있다. 상암DMC의 과거 개발 트렌드는 개인적인 환경기술 개발이 중심이 되었다. 현재에는 공공의 정보기술 중심으로 추진되고 있으나 일부는 환경을 중심으로 하는 준 융합개발의 트렌드를 갖고 있다. 그러나, 미래시대의 융합은 통합적 융합개발이 될 것이라 예측한다. 셋째, 메커니즘 구조는 생성, 소멸 그리고 융합과정에 의해 발전된다. 그 생성은 불충분한 부분으로부터 보충화 될 것이다. 소멸은 불충분한 부분의 융합과정에 의해서 함축화 될 것이다. 그리고 그러한 융합은 생성과 소멸의 기준이 될 것이다. 결국 새로운 창조 도시공간은 환경과 정보기술 중심의 메커니즘 기호화 패턴 구조에 의해 계속해서 형성 될 것이다.

암모니아 누출사고 시 주민대피 및 알림 결정을 위한 피해영향거리 산정식 개발 연구 (A Study on Development of Damage Impact Distance Calculation Formula to Determine Evacuation and Notification of Residents in Case of Ammonia Release Accident)

  • 김현섭;전병한;이명지;윤정현;이현승;정웅열;조정아
    • 한국산학기술학회논문지
    • /
    • 제21권10호
    • /
    • pp.308-316
    • /
    • 2020
  • 본 연구에서는 암모니아 누출사고 발생 시 지방자치단체에서 신속하게 주민대피 및 알림을 결정할 수 있도록 화학물질사고대응정보시스템(CARIS)을 활용한 피해영향거리 산정식을 도출하고자 하였다. 암모니아는 화학물질관리법상 사고대비물질이자 화학물질안전원에서 정한 주민대피 대비물질 16종 중 하나이며, 2014년부터 2019년 기간 동안 화학사고가 58건으로 가장 빈번하게 발생한 화학물질이다. 연구에서는 미국환경보호국(EPA)에서 지정하고, 유아 및 어린이, 노인 등의 취약집단을 포함하며 일반 인구에 적용 가능한 급성노출기준인 AEGL을 기준으로 암모니아의 노출시간에 따른 피해영향거리 산정식을 도출하였다. AEGL-3 농도기준에 따른 위험지역 구분과 AEGL-2 농도기준에 따른 준위험지역을 구분을 할 수 있는 농도별, 노출시간별 산정식을 도출하였으며, 도출된 산정식으로 얻어진 피해영향거리 수치와 화학물질사고대응정보시스템의 피해영향거리 수치간의 상대표준편차를 비교한 결과 0~2 % 범위인 것으로 조사되었다. 따라서 지방자치단체에서는 실제 사고 현장 상황을 고려하고 연구에서 도출된 적합한 피해영향거리 산정식을 적용하여 사고 원점 인근의 주민을 소산하거나 실내대피 알림 등의 보호조치에 활용될 수 있도록 하여야 한다.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.