Browse > Article
http://dx.doi.org/10.5572/KOSAE.2009.25.4.275

Estimation of PM10 Source Contributions on Three Cities in the Metropolitan Area by Using PMF Model  

Lee, Tae-Jung (College of Environment & Applied Chemistry and Center for Environmental Studies, Kyung Hee University-Global Campus)
Huh, Jong-Bae (School of Public Health, Department of Environmental Health, Seoul National University)
Yi, Seung-Muk (School of Public Health, Department of Environmental Health, Seoul National University)
Kim, Shin-Do (Department of Environmental Engineering, University of Seoul)
Kim, Dong-Sool (College of Environment & Applied Chemistry and Center for Environmental Studies, Kyung Hee University-Global Campus)
Publication Information
Journal of Korean Society for Atmospheric Environment / v.25, no.4, 2009 , pp. 275-288 More about this Journal
Abstract
The Korean government strengthened the environmental polices to manage and enhance Metropolitan Area air quality, and also has enforced "Special Act on Seoul Metropolitan Air Quality Improvement (SASMAQI)" issued in Dec. 2004. Recently government expanded the Seoul Metropolitan Air Quality Management District (SMAQMD) to the outskirts satellite cities of Seoul area through the "Revised Law Draft of SASMAQI". The SMAQMD has been alloted the allowable emission loads to the local governments on the basis of the carrying $PM_{10}$ capacity. However, in order to establish the effective air quality control strategy for $PM_{10}$, it is necessary to understand the corresponding sources which have a potential to directly impact ambient $PM_{10}$ concentration. To deal with the situations, many receptor methodologies have been developed to identify the origins of pollutants and to determine the contributions of sources of interests. The objective of this study was to extensively identify $PM_{10}$ sources and to estimate their contributions at the metropolitan area. $PM_{10}$ samples were simultaneously collected at the 3 semi-industrialized local cities in the Seoul metropolitan area such as Hwasung-si, Paju-si, and Icheon-si sites from April 15 to May 31, 2007. The samples collected on the teflon membrane filter by one $PM_{10}$ cyclone sampler were analyzed for trace metals and soluble ions and samples on the quartz fiber filter by another sampler were analyzed for OC and EC. Source apportionment study was then performed by using a positive matrix factorization (PMF) receptor model. A total of 6 sources were identified and their contributions were estimated in each monitoring site. Contribution results on Hwasung, Paju, and Icheon sites were as follows: 33%, 27%, and 27% from soil source, 26%, 26%, and 21% from secondary aerosol source, 11%, 11%, and 12% from biomass burning, 12%, 6%, and 5% from sea salt, 7%, 15%, and 19% from industrial related source, and finally 11%, 15%, and 16% from mobile and oil complex source, respectively. This study provides information on the major sources affecting air quality in the receptor sites and thus it will help to manage the ambient air quality in the metropolitan area by establishing reasonable control strategies, especially for the anthropogenic emission sources.
Keywords
$PM_{10}$; Receptor method; PMF; Sources; Metropolitan area; SMAQMD;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Pitts, F.B.J. and J.N. Pitts (2000) Chemistry of the Upper and Lower Atmosphere, Academic Press, San Diego, CA
2 Polissar, A.V., P.K. Hopke, W.C. Malm, and J.F. Sisler (1998) Atmospheric Aerosol over Alaska: 2. Elemental Composition and Sources, J. Geophys. Res., 103, 1147-1157   DOI
3 Shah, S.D., D.R. Cocker, III, J.W. Miller, and J.M. Norbeck (2004) Emission rates of particulate matter and elemental and organic carbon from in-use diesel engines, Environ. Sci. Technol., 38(9), 2544-2550   DOI   ScienceOn
4 Xie, Y.L., P.K. Hopke, P. Paatero, L.A. Barrie, and S.M. Li (1999) Identification of source nature and seasonal variations of Arctic aerosol by the multilinear engine, Atmospheric Environment, 33(16), 2549-2562   DOI   ScienceOn
5 이형우, 이태정, 양성수, 김동술(2008) PMF모델을 이용한 용인 . 수원 경계지역에서 PM10 오염원의 확인과 상대적 기여도의 추정, 한국대기환경학회지, 24(4), 439-454   DOI
6 환경부(2008) 대기환경연보 2007
7 황인조, 조영혁, 최우건, 이혜문, 김태오(2008) PMF를 응용한 구미시 PM-10 오염원의 정량적 기여도 추정 연구, 한국대기환경학회지, 24(1), 100-107   DOI
8 Lee, J.H., Y. Yoshida, B.J. Turpin, P.K. Hopke, R.L. Poirot, P.J. Lioy, and J.C. Oxley (2002) Identification of sources contributing to Mid-Atlantic regional aerosol, Air & Waste Manage. Assoc., 52(10), 1186-1205   DOI   ScienceOn
9 Lee, J.H. and P.K. Hopke (2006) Apportioning sources of $PM_{2.5}$ in St. Louis, MO using speciation trends network data. Atmospheric Environment, 40, S360-S377   DOI   ScienceOn
10 Paatero, P. (1997) Least Square Formulation of Robust Nonnegative Factor Analysis, Chemometrics and Intelligent Laboratory Systems, 37(1), 23-35   DOI   ScienceOn
11 U.S. EPA (1999) Air Quality Criteria for Particulate Matter, Volume I, EPA/600/P-99/002a
12 황인조, 김동술(2003) PMF 모델을 이용한 대기 중 PM-10 오염원의 정량적 기여도 추정, 한국대기환경학회지, 19(6), 719-731
13 환경부(2005) 수도권 대기환경관리 기본계획
14 U.S. EPA (2006) SPECIATE Ver 4.0
15 오미석, 이태정, 김동술(2009) PMF 모델을 이용한 용인-수원경계지역에서의 부유분진의 크기별 오염원 확인, 한국대기환경학회지, 25(2), 108-121   과학기술학회마을   DOI
16 문광주, 한진석, 공부주, 정일록, S.S. Cliff, T.A. Cahill, and K.D. Perry (2006) PMF 분석을 이용한 ACE-Asia 측정기간 중 제주 고산지역 입자상 물질의 입경별 발생원 추정, 한국대기환경학회지, 22(5), 590-603   과학기술학회마을
17 Paatero, P. and P.K. Hopke (2003) Discarding or down weighting high-noise variables in factor analytic models, Analytica Chimica Acta, 490(1), 277-289   DOI   ScienceOn
18 Song, X.H., A.V. Polissar, and P.K. Hopke (2001) Source of fine particle composition in the northeastern US, Atmospheric Environment, 35(31), 5277-5286   DOI   ScienceOn
19 Kim, E., P.K. Hopke, and E.S. Edgerton (2004) Improving source identification of Atlanta aerosol using temperature resolved carbon fractions in Positive Matrix Factorization, Atmospheric Environment, 38(2), 3349-3362   DOI   ScienceOn
20 Morawska, L. and J. Zhang (2002) Combustion sources of particles. 1. Health relevance and source signatures, Chemosphere, 49, 1045-1058   DOI   ScienceOn
21 Paatero, P., P.K. Hopke, B.A. Begum, and S.K. Biswas (2005) A graphical diagnostic method for assessing the rotation in factor analytical models of atmospheric pollution, Atmospheric Environment, 39, 193-201   DOI   ScienceOn
22 Hopke, P.K. (1985) Receptor Modeling in Environmental Chemistry, John Willy & Sons, New York
23 Lee, E., C.K. Chan, and P. Paatero (1999) Application of positive matrix factorization in source apportionment of particulate pollutants in Hong Kong, Atmospheric Environment, 33(19), 3201-3212   DOI   ScienceOn