• Title/Summary/Keyword: Semi-floor

Search Result 99, Processing Time 0.028 seconds

A Study on the Changes the Urban Space at Station Influenced Areas by the Open of Incheon Urban Railroad Line 1 (인천광역시 도시철도 1호선 개통에 따른 역세권 도시공간 변화 연구)

  • Ahn, Jung Geun;Park, Man Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.141-148
    • /
    • 2011
  • City of Incheon opened rapid transit(urban railroad line 1) in 1999 in order to relieve traffic congestion on major arterials. This research analyzed urban space changes of each station influenced area by examining the changes of residents, industrial employees, and floor area ratios before and after the open of Incheon urban railroad line 1. Analysis of variance was applied to change of station influence area. This research found out that the types of central business and agricultural station influence area had been changed significantly after the open of urban railroad. However, the residential, semi-residential, and suburban type of station influence area had not been changed after the open of urban railroad. Thus, it is necessary to provide diverse facilities for inducing residents and employees to the station influence area of residential and semi-residential. Furthermore, the suburban type of station influence area which is difficult to develop naturally by the law of Green Belt is needed to develop station influence area simultaneously with the construction of a station building.

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.

Semi-Automatic Method for Constructing 2D and 3D Indoor GIS Maps based on Point Clouds from Terrestrial LiDAR (지상 라이다의 점군 데이터를 이용한 2차원 및 3차원 실내 GIS 도면 반자동 구축 기법 개발)

  • Hong, Sung Chul;Jung, Jae Hoon;Kim, Sang Min;Hong, Seung Hwan;Heo, Joon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2013
  • In rapidly developing urban areas that include high-rise, large, and complex buildings, indoor and outdoor maps in GIS become a basis for utilizing and sharing information pertaining to various aspects of the real world. Although an indoor mapping has gained much attentions, research efforts are mostly in 2D and 3D modeling of terrain and buildings. Therefore, to facilitate fast and accurate construction of indoor GIS, this paper proposes a semi-automatic method consisting of preprocessing, 2D mapping, and 3D mapping stages. The preprocessing is designed to estimate heights of building interiors and to identify noise data from point clouds. In the 2D mapping, a floor map is extracted with a tracing grid and a refinement method. In the 3D mapping, a 3D wireframe model is created with heights from the preprocessing stage. 3D mesh data converted from noise data is combined with the 3D wireframe model for detail modeling. The proposed method was applied to point clouds depicting a hallway in a building. Experiment results indicate that the proposed method can be utilized to construct 2D and 3D maps for indoor GIS.

Effect of Feeding Prunus mume By-products on Productivity and Blood Composition in Semi-Broiler Chicks (매실 부산물 급여가 준육용계의 생산 능력과 혈액 성상에 미치는 영향)

  • Jeong, Y.D.;Cho, I.K.
    • Korean Journal of Poultry Science
    • /
    • v.34 no.4
    • /
    • pp.237-243
    • /
    • 2007
  • The objective of this experiment was to investigate the feeding influence of Prunus memu by-products (PMB) on productivity, blood composition, meat quality and intestinal microflora in semi-broiler chicks. Four hundred one day old chicks(Hanhyup 3) were raised in the floor pen with five treatments(0, 0.5, 1.0 2.0 3.0%) of four replicate for ten weeks. Basal diets contained 3,000, 3,100, 3,100, 3,200 kcal/kg ME and 22, 21, 19, 17% CP, respectively. There were no different performance for the first two weeks, but showed significantly different weight gain, feed intake in PMB 2.0, 3.0% addition treatments compared with control from three to five weeks of age. Weight gain of birds fed 2.0% PMB was significantly higher from nine to 10 weeks of age than control(P<0.05). Total weight gain tended to increase in PMB 1.0, 2.0, 3.0% addition treatments. Feed intake also showed increase in PMB 2.0, 3.0% addition treatments, but there were no different feed conversion. Total protein, albumin, cholesterol, neutral fat, glucose was significantly decreased in PMB 0.5% addition treatments compared with control. There were no different physico-chemical characteristics in breast meat. The number of yeast was significantly improved in PMB 3.0% compared with control(P<0.05), but found no difference in number of E. coli between control and PMB treatments. ND titer of birds fed PMB was not statistically different, but tended to decrease as dietary PMB increased. As the result of this experiment, PMB would be available as a feed additives in semi-broiler chicks.

Fabrication and characterization of 1.55$\mu$m SI-PBH DFB-LD for 10 Gbps optical fiber communications (10 Gb/s 급 광통신용 1.55$\mu$m SI-PBH DFB-LD의 제작 및 특성연구)

  • 김형문;김정수;오대곤;주흥로;박성수;송민규;곽봉신;김홍만;편광의
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.327-332
    • /
    • 1997
  • We fabricated the high speed 1.55${\mu}{\textrm}{m}$ distributed feedback laser diodes (DFB-LD) using both two-step mesa etching process and semi-insulating InP current blocking layers. The devices characteristics were threshold current of ~15mA, slope efficiency of ~0.13mW/mA, and dynamic resistance of ~6.0Ω, with as-cleaved facets. The fabricated DFB-LD showed the single longitudinal mode with more than 40dB up to 6 $I_{th}$(CW condition), emitting at the wavelength of 0.546${\mu}{\textrm}{m}$. The -3dB bandwidth was >10㎓ at the driving current of 27mA, and the maximum -3dB bandwidth was ~18㎓ at 90 mA current, showing the superior frequency response of SI-PBH DFB-LD. In the 10Gb/s transmission experiment for 1.55${\mu}{\textrm}{m}$ DFB-LD module, maximum 10 km of single mode fiber(SMF) or 80 km of dispersion shifted fiber (DSF) could be transmitted with error free.

  • PDF

Performance Evaluation of Vibration Control of Adjacent Buildings According to Installation Location of MR damper (인접건축물의 진동제어를 위한 MR감쇠기의 위치 선정에 관한 연구)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.91-99
    • /
    • 2012
  • In recently, the vibration control of adjacent buildings have been studied and magneto-rheological(MR) fluid dampers have been applied to seismic response control. MR dampers can be controlled with small power supplies and the dynamic range of this damping force is quite large. This MR damper is one of semi-active dampers as a new class of smart dampers. In this study, vibration control effect according to the installation location of the MR damper connected adjacent buildings has been investigated. Adjacent building structures with different natural frequencies were used as example structures. Groundhook control model is applied to determinate control force of MR damper. In this numerical analysis, it has been shown that displacement responses can be effectively controlled as adjacent buildings are connected at roof floors by MR damper. And acceleration responses can be effectively reduced when two buildings are connected at the mid-stories of adjacent buildings by MR damper. Therefore, the installation floor of the MR damper should be selected with seismic response control target.

Bending Capacity Evaluation of the Infilled Composite Beam with Semi-slim Closed Section (반슬림 폐단면 충전형 합성보의 휨성능 평가)

  • Lim, Hwan Taek;Choi, Byong Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.130-140
    • /
    • 2018
  • An AU-composite beam based on U-shaped steel beams and steel plate anchors of type A was developed. The composite beam reduced the height of the building floor and construction cost. In addition, it decreased the length of construction work, and improved the flexural strength and stiffness as a form of tubes. In this study, AU-composite beams were tested directly and their performance was evaluated through bending experiments. The strength of the specimens was increased initially by linear loads and reached a maximum strength due to destruction of the concrete slab. All of the experiments showed more than 85% of the maximum stress and performed gentle movement. In addition, there was good composite behavior with the steel plate anchor that had excellent composite effects and reached full strength until the maximum strength was reached. When the thickness of the steel plate was increase, the flexural stiffness and strength of the specimen were improved. Therefore, the flexural strength of AU-composite beams can be estimated using the flexural strength formula according to the KBC 2016.

Punching Shear Strength and Behavior of CFT Column to RC Flat Plate connections (CFT기둥-RC 무량판 접합부의 펀칭전단강도 및 거동)

  • Lee, Cheol Ho;Kim, Jin Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.4
    • /
    • pp.491-502
    • /
    • 2006
  • This paper summarizes full-scale test results on CFT column-to- flat plate connections has gained wide acceptance subjected to gravity loading. CFT construction has gained wide acceptance in a relatively short time in domestic building construction practice due to its various structural and construction advantages. However, efficient details for CFT column to flat plate connections have not been proposed yet. Based on the strategies that maximize economical field construction, several connecting schemes were proposed and tested. Test results showed strength and connection stiffness exceeding those of R/C flat p late counterparts. A semi-analytical procedure is presented to model the behavior of CFT column-to-flat plate connections. The five parameters to model elastic to post-punching catenary action range are calibrated based on the limited test data of t to progressive collapse prevention design is also illustrated.

Morphological Specificity in Cultured Starry Flounder Platichthys stellatus Reared in Artificial Facility

  • Kang, Duk-Young;Lee, Jong-Ha;Kim, Won-Jin;Kim, Hyo-Chan
    • Fisheries and Aquatic Sciences
    • /
    • v.15 no.2
    • /
    • pp.117-123
    • /
    • 2012
  • The starry flounder Platichthys stellatus, like all flatfish, exhibits conspicuous lateral asymmetry in numerous traits, most obvious of which is the migration of one eye to the other side of the head during metamorphosis. Additional changes related to eye migration include asymmetrical pigmentation, and a behavioral shift from larvae that exhibit upright, open-water swimming to juveniles and adults that lie on the ocean floor, eye side up. However, the morphology of these juveniles has been quite plastic in recent years, a phenomenon which is thought to be related to a diverse suite of semi-intensive and intensive larviculture methods. The cause of morphological abnormalities in the farmed flatfish is poorly understood. In the present study, we observe the features of morphological specificity and abnormality of immature fish (mean total length 23 cm) and survey the occurrence frequency of the specificity and abnormality of juvenile (mean total length 6.70 cm) in artificial culture facility. We find 2 types of abnormality (e.g., albino in ocular side and hypermelanosis in blind side) and 1 type of specificity (e.g., lateral polymorphism). These considerably differ from normal individuals (has sinistral eye and pigmented on only one side) by several characteristics (dextral eye, ocular side albinism, blind side hypermelanosis). The incidences of albinism, hypermelanosis, and body reversal are $10.1{\pm}2.56%$, $91.7{\pm}1.7%$, and $13.1{\pm}1.1%$, respectively. These suggest that these morphometric and morphological differences occur more in artificial environment during and just after metamorphosis.

A Study of the Residents' Use and Occupancy-Behavior in the Activity Areas of the Senior Nursing Facilities (노인요양시설 거주노인의 활동공간 이용행동 및 점유행태)

  • Lee, Min-Ah
    • Journal of Families and Better Life
    • /
    • v.27 no.5
    • /
    • pp.77-90
    • /
    • 2009
  • The purpose of this study was to investigate the residents' use and occupancy-behavior in the activity areas of the senior nursing facilities, and to provide basic information to establish the appropriate physical elements for planning the activity areas. For the study, the observations in five facilities were conducted for one day, from 10 a.m. to 4 p.m by four researchers. The results of the study are summarized as follows: First, most of the using behaviors in the activity areas were the doing nothing or sleeping. The meals and program services were provided in only one activity area of the floor and it showed that the unit care system was perfunctorily conducted at those facilities. In the representative activity area, its openness was the main physical element influencing the spatial using frequency, while the accessibility and the openness in the sub-activity area were most important. The seating arrangements having comers were helpful for residents' interactions. Second, while facility programs and meals were provided in the specific activity area, there was no residents' occupancy in other activity areas at the same time. There were interactions including residents' conversations and watching/observations in non-designated activity areas such as the nursing stations and near corridors. But the residents' interactions and self-regulations were blocked by absence of territoriality, monotonous spatial compositions and furniture arrangements, insecurity of residents' privacy, wide or narrow areas, and isolated spatial type. Based on the results at the above, basic guidelines for planning the activity areas of senior nursing facilities can be proposed as follows: First, the isolated type and the sight interception should be avoided in representative activity areas. It should be partitioned with couple of areas through the appropriate furniture arrangements, and be prepared semi-private spaces in non-designated areas such as nursing station for the interactions among the residents and the staff. Second, in activity areas for small group, the isolated type is not also good for the residents' accessibility. The residents' privacy should be confirmed through the various spatial compositions, and enough areas need to be sure for the diverse furniture arrangements.